Cargando…

Safety and efficacy of spinal loop rectangle and sublaminar wires for osteoporotic vertebral compression fracture fixation

BACKGROUND: Natural history of osteoporotic vertebral compression fractures (OVCFs), that is, collapse, loads the rigid pedicle screw rod construct in the absence of anterior column reconstruction, often leading to implant back outs. Semi rigid spinal loop rectangle and sublaminar wire construct all...

Descripción completa

Detalles Bibliográficos
Autores principales: Patil, Sanganagouda Shivanagouda, Bhojaraj, Shekhar Yashwant, Nene, Abhay Madhusudan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5532928/
https://www.ncbi.nlm.nih.gov/pubmed/28761521
http://dx.doi.org/10.4103/1793-5482.175648
_version_ 1783253543352795136
author Patil, Sanganagouda Shivanagouda
Bhojaraj, Shekhar Yashwant
Nene, Abhay Madhusudan
author_facet Patil, Sanganagouda Shivanagouda
Bhojaraj, Shekhar Yashwant
Nene, Abhay Madhusudan
author_sort Patil, Sanganagouda Shivanagouda
collection PubMed
description BACKGROUND: Natural history of osteoporotic vertebral compression fractures (OVCFs), that is, collapse, loads the rigid pedicle screw rod construct in the absence of anterior column reconstruction, often leading to implant back outs. Semi rigid spinal loop rectangle and sublaminar wire construct allows controlled axial collapse and does not require anterior column reconstruction. MATERIALS AND METHODS: This is a retrospective study of 50 consecutive patients of OVCFs. The immediate and final follow-up safety (neurologic deficit, implant failure/back out, revision surgeries, and infection) and efficacy (visual analog scale [VAS] score, axial collapse of the fracture, fracture union and retaining, and the attempted segmental deformity correction) parameters were compared to describe the utility of spinal loop rectangle and sublaminar wiring as a novel, low cost modality of spinal instrumentation for treating OVCFs. RESULTS: All the twelve patients with Frankel grade D neurologic deficit improved to Frankel grade E and six patients (out of 8) with Frankel grade C improved to Frankel grade E (and remaining two patients improved to Frankel grade D), following surgery. The average preoperative VAS score of 8.98 (ranging from 5 to 10) improved to 2.76 (ranging from 1 to 10) at final follow-up. Controlled collapse of anterior column, union of OVCF nonunion, and retaining of attempted deformity correction by sublaminar wire anchors cephalad and caudal to the transpedicular decompression was seen in each patient at the final follow-up. CONCLUSION: Spinal loop rectangle and sublaminar wiring construct are viable alternative options for stabilizing OVCFs.
format Online
Article
Text
id pubmed-5532928
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-55329282017-07-31 Safety and efficacy of spinal loop rectangle and sublaminar wires for osteoporotic vertebral compression fracture fixation Patil, Sanganagouda Shivanagouda Bhojaraj, Shekhar Yashwant Nene, Abhay Madhusudan Asian J Neurosurg Original Article BACKGROUND: Natural history of osteoporotic vertebral compression fractures (OVCFs), that is, collapse, loads the rigid pedicle screw rod construct in the absence of anterior column reconstruction, often leading to implant back outs. Semi rigid spinal loop rectangle and sublaminar wire construct allows controlled axial collapse and does not require anterior column reconstruction. MATERIALS AND METHODS: This is a retrospective study of 50 consecutive patients of OVCFs. The immediate and final follow-up safety (neurologic deficit, implant failure/back out, revision surgeries, and infection) and efficacy (visual analog scale [VAS] score, axial collapse of the fracture, fracture union and retaining, and the attempted segmental deformity correction) parameters were compared to describe the utility of spinal loop rectangle and sublaminar wiring as a novel, low cost modality of spinal instrumentation for treating OVCFs. RESULTS: All the twelve patients with Frankel grade D neurologic deficit improved to Frankel grade E and six patients (out of 8) with Frankel grade C improved to Frankel grade E (and remaining two patients improved to Frankel grade D), following surgery. The average preoperative VAS score of 8.98 (ranging from 5 to 10) improved to 2.76 (ranging from 1 to 10) at final follow-up. Controlled collapse of anterior column, union of OVCF nonunion, and retaining of attempted deformity correction by sublaminar wire anchors cephalad and caudal to the transpedicular decompression was seen in each patient at the final follow-up. CONCLUSION: Spinal loop rectangle and sublaminar wiring construct are viable alternative options for stabilizing OVCFs. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5532928/ /pubmed/28761521 http://dx.doi.org/10.4103/1793-5482.175648 Text en Copyright: © 2016 Asian Journal of Neurosurgery http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Patil, Sanganagouda Shivanagouda
Bhojaraj, Shekhar Yashwant
Nene, Abhay Madhusudan
Safety and efficacy of spinal loop rectangle and sublaminar wires for osteoporotic vertebral compression fracture fixation
title Safety and efficacy of spinal loop rectangle and sublaminar wires for osteoporotic vertebral compression fracture fixation
title_full Safety and efficacy of spinal loop rectangle and sublaminar wires for osteoporotic vertebral compression fracture fixation
title_fullStr Safety and efficacy of spinal loop rectangle and sublaminar wires for osteoporotic vertebral compression fracture fixation
title_full_unstemmed Safety and efficacy of spinal loop rectangle and sublaminar wires for osteoporotic vertebral compression fracture fixation
title_short Safety and efficacy of spinal loop rectangle and sublaminar wires for osteoporotic vertebral compression fracture fixation
title_sort safety and efficacy of spinal loop rectangle and sublaminar wires for osteoporotic vertebral compression fracture fixation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5532928/
https://www.ncbi.nlm.nih.gov/pubmed/28761521
http://dx.doi.org/10.4103/1793-5482.175648
work_keys_str_mv AT patilsanganagoudashivanagouda safetyandefficacyofspinallooprectangleandsublaminarwiresforosteoporoticvertebralcompressionfracturefixation
AT bhojarajshekharyashwant safetyandefficacyofspinallooprectangleandsublaminarwiresforosteoporoticvertebralcompressionfracturefixation
AT neneabhaymadhusudan safetyandefficacyofspinallooprectangleandsublaminarwiresforosteoporoticvertebralcompressionfracturefixation