Cargando…
The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review
Optical coherence tomography provides sections of tissues in a noncontact and noninvasive manner. The device measures the time delay and intensity of the light scattered or reflected from biological tissues, which results in tomographic imaging of their internal structure. This is achieved by scanni...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5534297/ https://www.ncbi.nlm.nih.gov/pubmed/29065642 http://dx.doi.org/10.1155/2017/7560645 |
_version_ | 1783253748706967552 |
---|---|
author | Machoy, Monika Seeliger, Julia Szyszka-Sommerfeld, Liliana Koprowski, Robert Gedrange, Tomasz Woźniak, Krzysztof |
author_facet | Machoy, Monika Seeliger, Julia Szyszka-Sommerfeld, Liliana Koprowski, Robert Gedrange, Tomasz Woźniak, Krzysztof |
author_sort | Machoy, Monika |
collection | PubMed |
description | Optical coherence tomography provides sections of tissues in a noncontact and noninvasive manner. The device measures the time delay and intensity of the light scattered or reflected from biological tissues, which results in tomographic imaging of their internal structure. This is achieved by scanning tissues at a resolution ranging from 1 to 15 μm. OCT enables real-time in situ imaging of tissues without the need for biopsy, histological procedures, or the use of X-rays, so it can be used in many fields of medicine. Its properties are not only particularly used in ophthalmology, in the diagnosis of all layers of the retina, but also increasingly in cardiology, gastroenterology, pulmonology, oncology, and dermatology. The basic properties of OCT, that is, noninvasiveness and low wattage of the used light, have also been appreciated in analytical technology by conservators, who use it to identify the quality and age of paintings, ceramics, or glass. Recently, the OCT technique of visualization is being tested in different fields of dentistry, which is depicted in the article. |
format | Online Article Text |
id | pubmed-5534297 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-55342972017-08-08 The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review Machoy, Monika Seeliger, Julia Szyszka-Sommerfeld, Liliana Koprowski, Robert Gedrange, Tomasz Woźniak, Krzysztof J Healthc Eng Review Article Optical coherence tomography provides sections of tissues in a noncontact and noninvasive manner. The device measures the time delay and intensity of the light scattered or reflected from biological tissues, which results in tomographic imaging of their internal structure. This is achieved by scanning tissues at a resolution ranging from 1 to 15 μm. OCT enables real-time in situ imaging of tissues without the need for biopsy, histological procedures, or the use of X-rays, so it can be used in many fields of medicine. Its properties are not only particularly used in ophthalmology, in the diagnosis of all layers of the retina, but also increasingly in cardiology, gastroenterology, pulmonology, oncology, and dermatology. The basic properties of OCT, that is, noninvasiveness and low wattage of the used light, have also been appreciated in analytical technology by conservators, who use it to identify the quality and age of paintings, ceramics, or glass. Recently, the OCT technique of visualization is being tested in different fields of dentistry, which is depicted in the article. Hindawi 2017 2017-07-16 /pmc/articles/PMC5534297/ /pubmed/29065642 http://dx.doi.org/10.1155/2017/7560645 Text en Copyright © 2017 Monika Machoy et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Review Article Machoy, Monika Seeliger, Julia Szyszka-Sommerfeld, Liliana Koprowski, Robert Gedrange, Tomasz Woźniak, Krzysztof The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review |
title | The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review |
title_full | The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review |
title_fullStr | The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review |
title_full_unstemmed | The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review |
title_short | The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review |
title_sort | use of optical coherence tomography in dental diagnostics: a state-of-the-art review |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5534297/ https://www.ncbi.nlm.nih.gov/pubmed/29065642 http://dx.doi.org/10.1155/2017/7560645 |
work_keys_str_mv | AT machoymonika theuseofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview AT seeligerjulia theuseofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview AT szyszkasommerfeldliliana theuseofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview AT koprowskirobert theuseofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview AT gedrangetomasz theuseofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview AT wozniakkrzysztof theuseofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview AT machoymonika useofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview AT seeligerjulia useofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview AT szyszkasommerfeldliliana useofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview AT koprowskirobert useofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview AT gedrangetomasz useofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview AT wozniakkrzysztof useofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview |