Cargando…

The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review

Optical coherence tomography provides sections of tissues in a noncontact and noninvasive manner. The device measures the time delay and intensity of the light scattered or reflected from biological tissues, which results in tomographic imaging of their internal structure. This is achieved by scanni...

Descripción completa

Detalles Bibliográficos
Autores principales: Machoy, Monika, Seeliger, Julia, Szyszka-Sommerfeld, Liliana, Koprowski, Robert, Gedrange, Tomasz, Woźniak, Krzysztof
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5534297/
https://www.ncbi.nlm.nih.gov/pubmed/29065642
http://dx.doi.org/10.1155/2017/7560645
_version_ 1783253748706967552
author Machoy, Monika
Seeliger, Julia
Szyszka-Sommerfeld, Liliana
Koprowski, Robert
Gedrange, Tomasz
Woźniak, Krzysztof
author_facet Machoy, Monika
Seeliger, Julia
Szyszka-Sommerfeld, Liliana
Koprowski, Robert
Gedrange, Tomasz
Woźniak, Krzysztof
author_sort Machoy, Monika
collection PubMed
description Optical coherence tomography provides sections of tissues in a noncontact and noninvasive manner. The device measures the time delay and intensity of the light scattered or reflected from biological tissues, which results in tomographic imaging of their internal structure. This is achieved by scanning tissues at a resolution ranging from 1 to 15 μm. OCT enables real-time in situ imaging of tissues without the need for biopsy, histological procedures, or the use of X-rays, so it can be used in many fields of medicine. Its properties are not only particularly used in ophthalmology, in the diagnosis of all layers of the retina, but also increasingly in cardiology, gastroenterology, pulmonology, oncology, and dermatology. The basic properties of OCT, that is, noninvasiveness and low wattage of the used light, have also been appreciated in analytical technology by conservators, who use it to identify the quality and age of paintings, ceramics, or glass. Recently, the OCT technique of visualization is being tested in different fields of dentistry, which is depicted in the article.
format Online
Article
Text
id pubmed-5534297
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-55342972017-08-08 The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review Machoy, Monika Seeliger, Julia Szyszka-Sommerfeld, Liliana Koprowski, Robert Gedrange, Tomasz Woźniak, Krzysztof J Healthc Eng Review Article Optical coherence tomography provides sections of tissues in a noncontact and noninvasive manner. The device measures the time delay and intensity of the light scattered or reflected from biological tissues, which results in tomographic imaging of their internal structure. This is achieved by scanning tissues at a resolution ranging from 1 to 15 μm. OCT enables real-time in situ imaging of tissues without the need for biopsy, histological procedures, or the use of X-rays, so it can be used in many fields of medicine. Its properties are not only particularly used in ophthalmology, in the diagnosis of all layers of the retina, but also increasingly in cardiology, gastroenterology, pulmonology, oncology, and dermatology. The basic properties of OCT, that is, noninvasiveness and low wattage of the used light, have also been appreciated in analytical technology by conservators, who use it to identify the quality and age of paintings, ceramics, or glass. Recently, the OCT technique of visualization is being tested in different fields of dentistry, which is depicted in the article. Hindawi 2017 2017-07-16 /pmc/articles/PMC5534297/ /pubmed/29065642 http://dx.doi.org/10.1155/2017/7560645 Text en Copyright © 2017 Monika Machoy et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Machoy, Monika
Seeliger, Julia
Szyszka-Sommerfeld, Liliana
Koprowski, Robert
Gedrange, Tomasz
Woźniak, Krzysztof
The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review
title The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review
title_full The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review
title_fullStr The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review
title_full_unstemmed The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review
title_short The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review
title_sort use of optical coherence tomography in dental diagnostics: a state-of-the-art review
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5534297/
https://www.ncbi.nlm.nih.gov/pubmed/29065642
http://dx.doi.org/10.1155/2017/7560645
work_keys_str_mv AT machoymonika theuseofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview
AT seeligerjulia theuseofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview
AT szyszkasommerfeldliliana theuseofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview
AT koprowskirobert theuseofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview
AT gedrangetomasz theuseofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview
AT wozniakkrzysztof theuseofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview
AT machoymonika useofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview
AT seeligerjulia useofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview
AT szyszkasommerfeldliliana useofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview
AT koprowskirobert useofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview
AT gedrangetomasz useofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview
AT wozniakkrzysztof useofopticalcoherencetomographyindentaldiagnosticsastateoftheartreview