Cargando…
Silicone Tracheobronchial Stent: A Rare Cause for Bronchoesophageal Fistula and Distortion of Airway Anatomy
Silicone tracheobronchial stents are being increasingly used in a large number of patients for the treatment of tracheal stenosis. One very rare complication due to tracheobronchial stenting is bronchoesophageal fistula (BEF), which has been associated with the use of metallic stents. We report intr...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5535582/ https://www.ncbi.nlm.nih.gov/pubmed/28701606 http://dx.doi.org/10.4103/aca.ACA_12_17 |
_version_ | 1783253864700444672 |
---|---|
author | Kumar, Bhupesh Munirathinam, Ganesh Kumar Puri, Goverdhan Dutt Mishra, Anand Kumar Arya, Virendra Kumar |
author_facet | Kumar, Bhupesh Munirathinam, Ganesh Kumar Puri, Goverdhan Dutt Mishra, Anand Kumar Arya, Virendra Kumar |
author_sort | Kumar, Bhupesh |
collection | PubMed |
description | Silicone tracheobronchial stents are being increasingly used in a large number of patients for the treatment of tracheal stenosis. One very rare complication due to tracheobronchial stenting is bronchoesophageal fistula (BEF), which has been associated with the use of metallic stents. We report intraoperative management of a patient undergoing repair of a BEF, following previous insertion of a silicone Y-stent that is soft in texture and has not been implicated for this complication till date. In addition, misalignment of this silicone tracheobronchial Y-stent resulted in a tracheal mucosal bulge proximal to the stent that vanished after its removal. |
format | Online Article Text |
id | pubmed-5535582 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-55355822017-08-14 Silicone Tracheobronchial Stent: A Rare Cause for Bronchoesophageal Fistula and Distortion of Airway Anatomy Kumar, Bhupesh Munirathinam, Ganesh Kumar Puri, Goverdhan Dutt Mishra, Anand Kumar Arya, Virendra Kumar Ann Card Anaesth Case Report Silicone tracheobronchial stents are being increasingly used in a large number of patients for the treatment of tracheal stenosis. One very rare complication due to tracheobronchial stenting is bronchoesophageal fistula (BEF), which has been associated with the use of metallic stents. We report intraoperative management of a patient undergoing repair of a BEF, following previous insertion of a silicone Y-stent that is soft in texture and has not been implicated for this complication till date. In addition, misalignment of this silicone tracheobronchial Y-stent resulted in a tracheal mucosal bulge proximal to the stent that vanished after its removal. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5535582/ /pubmed/28701606 http://dx.doi.org/10.4103/aca.ACA_12_17 Text en Copyright: © 2017 Annals of Cardiac Anaesthesia http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Case Report Kumar, Bhupesh Munirathinam, Ganesh Kumar Puri, Goverdhan Dutt Mishra, Anand Kumar Arya, Virendra Kumar Silicone Tracheobronchial Stent: A Rare Cause for Bronchoesophageal Fistula and Distortion of Airway Anatomy |
title | Silicone Tracheobronchial Stent: A Rare Cause for Bronchoesophageal Fistula and Distortion of Airway Anatomy |
title_full | Silicone Tracheobronchial Stent: A Rare Cause for Bronchoesophageal Fistula and Distortion of Airway Anatomy |
title_fullStr | Silicone Tracheobronchial Stent: A Rare Cause for Bronchoesophageal Fistula and Distortion of Airway Anatomy |
title_full_unstemmed | Silicone Tracheobronchial Stent: A Rare Cause for Bronchoesophageal Fistula and Distortion of Airway Anatomy |
title_short | Silicone Tracheobronchial Stent: A Rare Cause for Bronchoesophageal Fistula and Distortion of Airway Anatomy |
title_sort | silicone tracheobronchial stent: a rare cause for bronchoesophageal fistula and distortion of airway anatomy |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5535582/ https://www.ncbi.nlm.nih.gov/pubmed/28701606 http://dx.doi.org/10.4103/aca.ACA_12_17 |
work_keys_str_mv | AT kumarbhupesh siliconetracheobronchialstentararecauseforbronchoesophagealfistulaanddistortionofairwayanatomy AT munirathinamganeshkumar siliconetracheobronchialstentararecauseforbronchoesophagealfistulaanddistortionofairwayanatomy AT purigoverdhandutt siliconetracheobronchialstentararecauseforbronchoesophagealfistulaanddistortionofairwayanatomy AT mishraanandkumar siliconetracheobronchialstentararecauseforbronchoesophagealfistulaanddistortionofairwayanatomy AT aryavirendrakumar siliconetracheobronchialstentararecauseforbronchoesophagealfistulaanddistortionofairwayanatomy |