Cargando…

Analytic and Diagnostic Performances of Human Papillomavirus E6/E7 mRNA Test on up-to 11-Year-Old Liquid-Based Cervical Samples. A Biobank-Based Longitudinal Study

Human Papillomavirus (HPV) E6/E7 mRNA test demonstrated high specificity in detecting HPV infections, but studies assessing its efficacy in terms of cancer risk stratification are lacking. Follow-up studies are arduous and expensive. Biobank would be the answer to the problem, although data investig...

Descripción completa

Detalles Bibliográficos
Autores principales: Zappacosta, Roberta, Sablone, Francesca, Pansa, Lucia, Buca, Davide, Buca, Danilo, Rosini, Sandra
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5535970/
https://www.ncbi.nlm.nih.gov/pubmed/28696386
http://dx.doi.org/10.3390/ijms18071480
_version_ 1783253936782704640
author Zappacosta, Roberta
Sablone, Francesca
Pansa, Lucia
Buca, Davide
Buca, Danilo
Rosini, Sandra
author_facet Zappacosta, Roberta
Sablone, Francesca
Pansa, Lucia
Buca, Davide
Buca, Danilo
Rosini, Sandra
author_sort Zappacosta, Roberta
collection PubMed
description Human Papillomavirus (HPV) E6/E7 mRNA test demonstrated high specificity in detecting HPV infections, but studies assessing its efficacy in terms of cancer risk stratification are lacking. Follow-up studies are arduous and expensive. Biobank would be the answer to the problem, although data investigating the effects of long-term storage on RNA preservation are still needed. We addressed these issues by retrieving 202 residual liquid-based cervical specimens, collected from 149 women attending cervical cancer screening during the years 2001–2012. Samples were stored in Adriatic Biobank at room temperature and without any handing. After calculation of RNA yield and purity, E6/E7 mRNA test was retrospectively performed on each samples, to assess analytic and diagnostic performances. Using automated extraction procedures, RNA of good quantity and quality was obtained. The mean value of RNA concentration was 27.5 ng/μL. The mean A260/A280 ratio was 2.1. An invalid mRNA test result was found in 11.9% of the specimens. Neither RNA integrity, nor analytic performances of mRNA test were influenced by the year of sample collection. In total, 62.4% of the specimens tested as mRNA positive; among these, 89.2% were CIN2+. E6/E7 mRNA was detected in all Squamous Cervical Cancer (SCC) cases. Percentage of positive samples increased with the severity of histological diagnosis. mRNA testing, showing specificity and predictive values of 75.6% and 84.4%, respectively, significantly improved the corresponding values for DNA testing. Thus, the reflex mRNA test was demonstrated to be suitable to triage women with persistent cervical lesions. A “one sample for all” approach is possible, with practical benefits for Biobank-based long-term longitudinal studies, diseases prevention, prediction, diagnosis and treatment.
format Online
Article
Text
id pubmed-5535970
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-55359702017-08-04 Analytic and Diagnostic Performances of Human Papillomavirus E6/E7 mRNA Test on up-to 11-Year-Old Liquid-Based Cervical Samples. A Biobank-Based Longitudinal Study Zappacosta, Roberta Sablone, Francesca Pansa, Lucia Buca, Davide Buca, Danilo Rosini, Sandra Int J Mol Sci Article Human Papillomavirus (HPV) E6/E7 mRNA test demonstrated high specificity in detecting HPV infections, but studies assessing its efficacy in terms of cancer risk stratification are lacking. Follow-up studies are arduous and expensive. Biobank would be the answer to the problem, although data investigating the effects of long-term storage on RNA preservation are still needed. We addressed these issues by retrieving 202 residual liquid-based cervical specimens, collected from 149 women attending cervical cancer screening during the years 2001–2012. Samples were stored in Adriatic Biobank at room temperature and without any handing. After calculation of RNA yield and purity, E6/E7 mRNA test was retrospectively performed on each samples, to assess analytic and diagnostic performances. Using automated extraction procedures, RNA of good quantity and quality was obtained. The mean value of RNA concentration was 27.5 ng/μL. The mean A260/A280 ratio was 2.1. An invalid mRNA test result was found in 11.9% of the specimens. Neither RNA integrity, nor analytic performances of mRNA test were influenced by the year of sample collection. In total, 62.4% of the specimens tested as mRNA positive; among these, 89.2% were CIN2+. E6/E7 mRNA was detected in all Squamous Cervical Cancer (SCC) cases. Percentage of positive samples increased with the severity of histological diagnosis. mRNA testing, showing specificity and predictive values of 75.6% and 84.4%, respectively, significantly improved the corresponding values for DNA testing. Thus, the reflex mRNA test was demonstrated to be suitable to triage women with persistent cervical lesions. A “one sample for all” approach is possible, with practical benefits for Biobank-based long-term longitudinal studies, diseases prevention, prediction, diagnosis and treatment. MDPI 2017-07-11 /pmc/articles/PMC5535970/ /pubmed/28696386 http://dx.doi.org/10.3390/ijms18071480 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zappacosta, Roberta
Sablone, Francesca
Pansa, Lucia
Buca, Davide
Buca, Danilo
Rosini, Sandra
Analytic and Diagnostic Performances of Human Papillomavirus E6/E7 mRNA Test on up-to 11-Year-Old Liquid-Based Cervical Samples. A Biobank-Based Longitudinal Study
title Analytic and Diagnostic Performances of Human Papillomavirus E6/E7 mRNA Test on up-to 11-Year-Old Liquid-Based Cervical Samples. A Biobank-Based Longitudinal Study
title_full Analytic and Diagnostic Performances of Human Papillomavirus E6/E7 mRNA Test on up-to 11-Year-Old Liquid-Based Cervical Samples. A Biobank-Based Longitudinal Study
title_fullStr Analytic and Diagnostic Performances of Human Papillomavirus E6/E7 mRNA Test on up-to 11-Year-Old Liquid-Based Cervical Samples. A Biobank-Based Longitudinal Study
title_full_unstemmed Analytic and Diagnostic Performances of Human Papillomavirus E6/E7 mRNA Test on up-to 11-Year-Old Liquid-Based Cervical Samples. A Biobank-Based Longitudinal Study
title_short Analytic and Diagnostic Performances of Human Papillomavirus E6/E7 mRNA Test on up-to 11-Year-Old Liquid-Based Cervical Samples. A Biobank-Based Longitudinal Study
title_sort analytic and diagnostic performances of human papillomavirus e6/e7 mrna test on up-to 11-year-old liquid-based cervical samples. a biobank-based longitudinal study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5535970/
https://www.ncbi.nlm.nih.gov/pubmed/28696386
http://dx.doi.org/10.3390/ijms18071480
work_keys_str_mv AT zappacostaroberta analyticanddiagnosticperformancesofhumanpapillomaviruse6e7mrnatestonupto11yearoldliquidbasedcervicalsamplesabiobankbasedlongitudinalstudy
AT sablonefrancesca analyticanddiagnosticperformancesofhumanpapillomaviruse6e7mrnatestonupto11yearoldliquidbasedcervicalsamplesabiobankbasedlongitudinalstudy
AT pansalucia analyticanddiagnosticperformancesofhumanpapillomaviruse6e7mrnatestonupto11yearoldliquidbasedcervicalsamplesabiobankbasedlongitudinalstudy
AT bucadavide analyticanddiagnosticperformancesofhumanpapillomaviruse6e7mrnatestonupto11yearoldliquidbasedcervicalsamplesabiobankbasedlongitudinalstudy
AT bucadanilo analyticanddiagnosticperformancesofhumanpapillomaviruse6e7mrnatestonupto11yearoldliquidbasedcervicalsamplesabiobankbasedlongitudinalstudy
AT rosinisandra analyticanddiagnosticperformancesofhumanpapillomaviruse6e7mrnatestonupto11yearoldliquidbasedcervicalsamplesabiobankbasedlongitudinalstudy