Cargando…

Accuracy of Bone Measurements in the Vicinity of Titanium Implants in CBCT Data Sets: A Comparison of Radiological and Histological Findings in Minipigs

PURPOSE: The aim of this animal study was the determination of accuracy of bone measurements in CBCT (cone-beam computed tomography) in close proximity to titanium implants. MATERIAL AND METHODS: Titanium implants were inserted in eight Göttingen minipigs. 60 implants were evaluated histologically i...

Descripción completa

Detalles Bibliográficos
Autores principales: Gröbe, Alexander, Semmusch, Jan, Schöllchen, Maximilian, Hanken, Henning, Hahn, Michael, Eichhorn, Wolfgang, Schön, Gerhard, Jung, Ole, Stein, Jamal M., Reitmeier, Aline, Heiland, Max, Smeets, Ralf, Precht, Clarissa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5536141/
https://www.ncbi.nlm.nih.gov/pubmed/28798929
http://dx.doi.org/10.1155/2017/3848207
_version_ 1783253969927143424
author Gröbe, Alexander
Semmusch, Jan
Schöllchen, Maximilian
Hanken, Henning
Hahn, Michael
Eichhorn, Wolfgang
Schön, Gerhard
Jung, Ole
Stein, Jamal M.
Reitmeier, Aline
Heiland, Max
Smeets, Ralf
Precht, Clarissa
author_facet Gröbe, Alexander
Semmusch, Jan
Schöllchen, Maximilian
Hanken, Henning
Hahn, Michael
Eichhorn, Wolfgang
Schön, Gerhard
Jung, Ole
Stein, Jamal M.
Reitmeier, Aline
Heiland, Max
Smeets, Ralf
Precht, Clarissa
author_sort Gröbe, Alexander
collection PubMed
description PURPOSE: The aim of this animal study was the determination of accuracy of bone measurements in CBCT (cone-beam computed tomography) in close proximity to titanium implants. MATERIAL AND METHODS: Titanium implants were inserted in eight Göttingen minipigs. 60 implants were evaluated histologically in ground section specimen and radiologically in CBCT in regard to thickness of the buccal bone. With random intercept models, the difference of histologic measurements and CBCT measurements of bone thickness was calculated. RESULTS: The mean histological thickness of the buccal bone was 5.09 mm (CI 4.11–6.08 mm). The four raters measured slightly less bone in CBCT than it was found in histology. The random effect was not significant (p value 1.000). Therefore, the Intraclass Correlation Coefficient (ICC) was 98.65% (CI 100.00–96.99%). CONCLUSION: CBCT is an accurate technique to measure even thin bone structures in the vicinity of titanium implants.
format Online
Article
Text
id pubmed-5536141
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-55361412017-08-10 Accuracy of Bone Measurements in the Vicinity of Titanium Implants in CBCT Data Sets: A Comparison of Radiological and Histological Findings in Minipigs Gröbe, Alexander Semmusch, Jan Schöllchen, Maximilian Hanken, Henning Hahn, Michael Eichhorn, Wolfgang Schön, Gerhard Jung, Ole Stein, Jamal M. Reitmeier, Aline Heiland, Max Smeets, Ralf Precht, Clarissa Biomed Res Int Research Article PURPOSE: The aim of this animal study was the determination of accuracy of bone measurements in CBCT (cone-beam computed tomography) in close proximity to titanium implants. MATERIAL AND METHODS: Titanium implants were inserted in eight Göttingen minipigs. 60 implants were evaluated histologically in ground section specimen and radiologically in CBCT in regard to thickness of the buccal bone. With random intercept models, the difference of histologic measurements and CBCT measurements of bone thickness was calculated. RESULTS: The mean histological thickness of the buccal bone was 5.09 mm (CI 4.11–6.08 mm). The four raters measured slightly less bone in CBCT than it was found in histology. The random effect was not significant (p value 1.000). Therefore, the Intraclass Correlation Coefficient (ICC) was 98.65% (CI 100.00–96.99%). CONCLUSION: CBCT is an accurate technique to measure even thin bone structures in the vicinity of titanium implants. Hindawi 2017 2017-07-17 /pmc/articles/PMC5536141/ /pubmed/28798929 http://dx.doi.org/10.1155/2017/3848207 Text en Copyright © 2017 Alexander Gröbe et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Gröbe, Alexander
Semmusch, Jan
Schöllchen, Maximilian
Hanken, Henning
Hahn, Michael
Eichhorn, Wolfgang
Schön, Gerhard
Jung, Ole
Stein, Jamal M.
Reitmeier, Aline
Heiland, Max
Smeets, Ralf
Precht, Clarissa
Accuracy of Bone Measurements in the Vicinity of Titanium Implants in CBCT Data Sets: A Comparison of Radiological and Histological Findings in Minipigs
title Accuracy of Bone Measurements in the Vicinity of Titanium Implants in CBCT Data Sets: A Comparison of Radiological and Histological Findings in Minipigs
title_full Accuracy of Bone Measurements in the Vicinity of Titanium Implants in CBCT Data Sets: A Comparison of Radiological and Histological Findings in Minipigs
title_fullStr Accuracy of Bone Measurements in the Vicinity of Titanium Implants in CBCT Data Sets: A Comparison of Radiological and Histological Findings in Minipigs
title_full_unstemmed Accuracy of Bone Measurements in the Vicinity of Titanium Implants in CBCT Data Sets: A Comparison of Radiological and Histological Findings in Minipigs
title_short Accuracy of Bone Measurements in the Vicinity of Titanium Implants in CBCT Data Sets: A Comparison of Radiological and Histological Findings in Minipigs
title_sort accuracy of bone measurements in the vicinity of titanium implants in cbct data sets: a comparison of radiological and histological findings in minipigs
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5536141/
https://www.ncbi.nlm.nih.gov/pubmed/28798929
http://dx.doi.org/10.1155/2017/3848207
work_keys_str_mv AT grobealexander accuracyofbonemeasurementsinthevicinityoftitaniumimplantsincbctdatasetsacomparisonofradiologicalandhistologicalfindingsinminipigs
AT semmuschjan accuracyofbonemeasurementsinthevicinityoftitaniumimplantsincbctdatasetsacomparisonofradiologicalandhistologicalfindingsinminipigs
AT schollchenmaximilian accuracyofbonemeasurementsinthevicinityoftitaniumimplantsincbctdatasetsacomparisonofradiologicalandhistologicalfindingsinminipigs
AT hankenhenning accuracyofbonemeasurementsinthevicinityoftitaniumimplantsincbctdatasetsacomparisonofradiologicalandhistologicalfindingsinminipigs
AT hahnmichael accuracyofbonemeasurementsinthevicinityoftitaniumimplantsincbctdatasetsacomparisonofradiologicalandhistologicalfindingsinminipigs
AT eichhornwolfgang accuracyofbonemeasurementsinthevicinityoftitaniumimplantsincbctdatasetsacomparisonofradiologicalandhistologicalfindingsinminipigs
AT schongerhard accuracyofbonemeasurementsinthevicinityoftitaniumimplantsincbctdatasetsacomparisonofradiologicalandhistologicalfindingsinminipigs
AT jungole accuracyofbonemeasurementsinthevicinityoftitaniumimplantsincbctdatasetsacomparisonofradiologicalandhistologicalfindingsinminipigs
AT steinjamalm accuracyofbonemeasurementsinthevicinityoftitaniumimplantsincbctdatasetsacomparisonofradiologicalandhistologicalfindingsinminipigs
AT reitmeieraline accuracyofbonemeasurementsinthevicinityoftitaniumimplantsincbctdatasetsacomparisonofradiologicalandhistologicalfindingsinminipigs
AT heilandmax accuracyofbonemeasurementsinthevicinityoftitaniumimplantsincbctdatasetsacomparisonofradiologicalandhistologicalfindingsinminipigs
AT smeetsralf accuracyofbonemeasurementsinthevicinityoftitaniumimplantsincbctdatasetsacomparisonofradiologicalandhistologicalfindingsinminipigs
AT prechtclarissa accuracyofbonemeasurementsinthevicinityoftitaniumimplantsincbctdatasetsacomparisonofradiologicalandhistologicalfindingsinminipigs