Cargando…
A Glucose Sensing System Based on Transmission Measurements at Millimetre Waves using Micro strip Patch Antennas
We present a sensing system operating at millimetre (mm) waves in transmission mode that can measure glucose level changes based on the complex permittivity changes across the signal path. The permittivity of a sample can change significantly as the concentration of one of its substances varies: for...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5537249/ https://www.ncbi.nlm.nih.gov/pubmed/28761121 http://dx.doi.org/10.1038/s41598-017-06926-1 |
_version_ | 1783254134337568768 |
---|---|
author | Saha, Shimul Cano-Garcia, Helena Sotiriou, Ioannis Lipscombe, Oliver Gouzouasis, Ioannis Koutsoupidou, Maria Palikaras, George Mackenzie, Richard Reeve, Thomas Kosmas, Panagiotis Kallos, Efthymios |
author_facet | Saha, Shimul Cano-Garcia, Helena Sotiriou, Ioannis Lipscombe, Oliver Gouzouasis, Ioannis Koutsoupidou, Maria Palikaras, George Mackenzie, Richard Reeve, Thomas Kosmas, Panagiotis Kallos, Efthymios |
author_sort | Saha, Shimul |
collection | PubMed |
description | We present a sensing system operating at millimetre (mm) waves in transmission mode that can measure glucose level changes based on the complex permittivity changes across the signal path. The permittivity of a sample can change significantly as the concentration of one of its substances varies: for example, blood permittivity depends on the blood glucose levels. The proposed sensing system uses two facing microstrip patch antennas operating at 60 GHz, which are placed across interrogated samples. The measured transmission coefficient depends on the permittivity change along the signal path, which can be correlated to the change in concentration of a substance. Along with theoretical estimations, we experimentally demonstrate the sensing performance of the system using controlled laboratory samples, such as water-based glucose-loaded liquid samples. We also present results of successful glucose spike detection in humans during an in-vivo Intravenous Glucose Tolerance Test (IVGTT). The system could eventually be developed into a non-invasive glucose monitor for continuous monitoring of glucose levels for people living with diabetes, as it can detect as small as 1.33 mmol/l (0.025 wt%) glucose concentrations in the controlled water-based samples satisfactorily, which is well below the typical human glucose levels of 4 mmol/l. |
format | Online Article Text |
id | pubmed-5537249 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-55372492017-08-03 A Glucose Sensing System Based on Transmission Measurements at Millimetre Waves using Micro strip Patch Antennas Saha, Shimul Cano-Garcia, Helena Sotiriou, Ioannis Lipscombe, Oliver Gouzouasis, Ioannis Koutsoupidou, Maria Palikaras, George Mackenzie, Richard Reeve, Thomas Kosmas, Panagiotis Kallos, Efthymios Sci Rep Article We present a sensing system operating at millimetre (mm) waves in transmission mode that can measure glucose level changes based on the complex permittivity changes across the signal path. The permittivity of a sample can change significantly as the concentration of one of its substances varies: for example, blood permittivity depends on the blood glucose levels. The proposed sensing system uses two facing microstrip patch antennas operating at 60 GHz, which are placed across interrogated samples. The measured transmission coefficient depends on the permittivity change along the signal path, which can be correlated to the change in concentration of a substance. Along with theoretical estimations, we experimentally demonstrate the sensing performance of the system using controlled laboratory samples, such as water-based glucose-loaded liquid samples. We also present results of successful glucose spike detection in humans during an in-vivo Intravenous Glucose Tolerance Test (IVGTT). The system could eventually be developed into a non-invasive glucose monitor for continuous monitoring of glucose levels for people living with diabetes, as it can detect as small as 1.33 mmol/l (0.025 wt%) glucose concentrations in the controlled water-based samples satisfactorily, which is well below the typical human glucose levels of 4 mmol/l. Nature Publishing Group UK 2017-07-31 /pmc/articles/PMC5537249/ /pubmed/28761121 http://dx.doi.org/10.1038/s41598-017-06926-1 Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Saha, Shimul Cano-Garcia, Helena Sotiriou, Ioannis Lipscombe, Oliver Gouzouasis, Ioannis Koutsoupidou, Maria Palikaras, George Mackenzie, Richard Reeve, Thomas Kosmas, Panagiotis Kallos, Efthymios A Glucose Sensing System Based on Transmission Measurements at Millimetre Waves using Micro strip Patch Antennas |
title | A Glucose Sensing System Based on Transmission Measurements at Millimetre Waves using Micro strip Patch Antennas |
title_full | A Glucose Sensing System Based on Transmission Measurements at Millimetre Waves using Micro strip Patch Antennas |
title_fullStr | A Glucose Sensing System Based on Transmission Measurements at Millimetre Waves using Micro strip Patch Antennas |
title_full_unstemmed | A Glucose Sensing System Based on Transmission Measurements at Millimetre Waves using Micro strip Patch Antennas |
title_short | A Glucose Sensing System Based on Transmission Measurements at Millimetre Waves using Micro strip Patch Antennas |
title_sort | glucose sensing system based on transmission measurements at millimetre waves using micro strip patch antennas |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5537249/ https://www.ncbi.nlm.nih.gov/pubmed/28761121 http://dx.doi.org/10.1038/s41598-017-06926-1 |
work_keys_str_mv | AT sahashimul aglucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT canogarciahelena aglucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT sotiriouioannis aglucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT lipscombeoliver aglucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT gouzouasisioannis aglucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT koutsoupidoumaria aglucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT palikarasgeorge aglucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT mackenzierichard aglucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT reevethomas aglucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT kosmaspanagiotis aglucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT kallosefthymios aglucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT sahashimul glucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT canogarciahelena glucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT sotiriouioannis glucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT lipscombeoliver glucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT gouzouasisioannis glucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT koutsoupidoumaria glucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT palikarasgeorge glucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT mackenzierichard glucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT reevethomas glucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT kosmaspanagiotis glucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas AT kallosefthymios glucosesensingsystembasedontransmissionmeasurementsatmillimetrewavesusingmicrostrippatchantennas |