Cargando…
Intra- and Inter-observer Reliability of Quadriceps Muscle Thickness Measured with Bedside Ultrasonography by Critical Care Physicians
BACKGROUND: Muscle wasting is common among critically ill patients with sepsis and has a significant effect on clinical outcome. However, appropriate tool for measurement of muscle loss is debatable. Ultrasonography (USG) has been used for objective assessment of quadriceps muscle thickness among th...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5538093/ https://www.ncbi.nlm.nih.gov/pubmed/28808365 http://dx.doi.org/10.4103/ijccm.IJCCM_426_16 |
_version_ | 1783254302550130688 |
---|---|
author | Hadda, Vijay Khilnani, Gopi C. Kumar, Rohit Dhunguna, Ashesh Mittal, Saurabh Khan, Maroof Ahmad Madan, Karan Mohan, Anant Guleria, Randeep |
author_facet | Hadda, Vijay Khilnani, Gopi C. Kumar, Rohit Dhunguna, Ashesh Mittal, Saurabh Khan, Maroof Ahmad Madan, Karan Mohan, Anant Guleria, Randeep |
author_sort | Hadda, Vijay |
collection | PubMed |
description | BACKGROUND: Muscle wasting is common among critically ill patients with sepsis and has a significant effect on clinical outcome. However, appropriate tool for measurement of muscle loss is debatable. Ultrasonography (USG) has been used for objective assessment of quadriceps muscle thickness among these patients; however, there is limited data on its reliability. AIMS AND OBJECTIVE: This study was aimed to assess the reliability of quadriceps muscle thickness as measured by critical care physicians. METHODOLOGY: This cross-sectional study included twenty patients with sepsis. Quadriceps muscle thickness was measured on right mid-thigh at a predefined point by two critical care fellows using bedside USG. Intra- and inter-observer reliability of the measurements was assessed by intra-class correlation coefficient (ICC). RESULTS: Hundred and twenty quadriceps muscle thickness measurements, three by each of the two critical care fellows, were done in twenty patients with sepsis. First, second, and third measurements (mean ± standard deviation) taken by the first observer (RK) were 35.030 ± 3.546 mm, 35.055 ± 3.307 mm, and 35.245 ± 3.027 mm, respectively. The three values recorded by the second observer (AD) were 35.585 ± 3.746 mm, 35.1 ± 3.006 mm, and 34.89 ± 2.556 mm, respectively. ICC for observer 1 and 2 was 0.925 (95% confidence interval [CI]: 0.851–0.967) and 0.835 (95% CI: 0.689–0.925), respectively. The mean difference of measurement between two observers was 0.082 mm (95% CI: −1.194–1.031). The mean ICC (95% CI) for inter-observer reliability was 0.992 (0.979–0.997); P < 0.001. CONCLUSIONS: This study shows that ultrasound is a reliable tool for the measurement of quadriceps muscle thickness by critical care physicians with excellent inter- and intra-class reliability. |
format | Online Article Text |
id | pubmed-5538093 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-55380932017-08-14 Intra- and Inter-observer Reliability of Quadriceps Muscle Thickness Measured with Bedside Ultrasonography by Critical Care Physicians Hadda, Vijay Khilnani, Gopi C. Kumar, Rohit Dhunguna, Ashesh Mittal, Saurabh Khan, Maroof Ahmad Madan, Karan Mohan, Anant Guleria, Randeep Indian J Crit Care Med Research Article BACKGROUND: Muscle wasting is common among critically ill patients with sepsis and has a significant effect on clinical outcome. However, appropriate tool for measurement of muscle loss is debatable. Ultrasonography (USG) has been used for objective assessment of quadriceps muscle thickness among these patients; however, there is limited data on its reliability. AIMS AND OBJECTIVE: This study was aimed to assess the reliability of quadriceps muscle thickness as measured by critical care physicians. METHODOLOGY: This cross-sectional study included twenty patients with sepsis. Quadriceps muscle thickness was measured on right mid-thigh at a predefined point by two critical care fellows using bedside USG. Intra- and inter-observer reliability of the measurements was assessed by intra-class correlation coefficient (ICC). RESULTS: Hundred and twenty quadriceps muscle thickness measurements, three by each of the two critical care fellows, were done in twenty patients with sepsis. First, second, and third measurements (mean ± standard deviation) taken by the first observer (RK) were 35.030 ± 3.546 mm, 35.055 ± 3.307 mm, and 35.245 ± 3.027 mm, respectively. The three values recorded by the second observer (AD) were 35.585 ± 3.746 mm, 35.1 ± 3.006 mm, and 34.89 ± 2.556 mm, respectively. ICC for observer 1 and 2 was 0.925 (95% confidence interval [CI]: 0.851–0.967) and 0.835 (95% CI: 0.689–0.925), respectively. The mean difference of measurement between two observers was 0.082 mm (95% CI: −1.194–1.031). The mean ICC (95% CI) for inter-observer reliability was 0.992 (0.979–0.997); P < 0.001. CONCLUSIONS: This study shows that ultrasound is a reliable tool for the measurement of quadriceps muscle thickness by critical care physicians with excellent inter- and intra-class reliability. Medknow Publications & Media Pvt Ltd 2017-07 /pmc/articles/PMC5538093/ /pubmed/28808365 http://dx.doi.org/10.4103/ijccm.IJCCM_426_16 Text en Copyright: © 2017 Indian Journal of Critical Care Medicine http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Research Article Hadda, Vijay Khilnani, Gopi C. Kumar, Rohit Dhunguna, Ashesh Mittal, Saurabh Khan, Maroof Ahmad Madan, Karan Mohan, Anant Guleria, Randeep Intra- and Inter-observer Reliability of Quadriceps Muscle Thickness Measured with Bedside Ultrasonography by Critical Care Physicians |
title | Intra- and Inter-observer Reliability of Quadriceps Muscle Thickness Measured with Bedside Ultrasonography by Critical Care Physicians |
title_full | Intra- and Inter-observer Reliability of Quadriceps Muscle Thickness Measured with Bedside Ultrasonography by Critical Care Physicians |
title_fullStr | Intra- and Inter-observer Reliability of Quadriceps Muscle Thickness Measured with Bedside Ultrasonography by Critical Care Physicians |
title_full_unstemmed | Intra- and Inter-observer Reliability of Quadriceps Muscle Thickness Measured with Bedside Ultrasonography by Critical Care Physicians |
title_short | Intra- and Inter-observer Reliability of Quadriceps Muscle Thickness Measured with Bedside Ultrasonography by Critical Care Physicians |
title_sort | intra- and inter-observer reliability of quadriceps muscle thickness measured with bedside ultrasonography by critical care physicians |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5538093/ https://www.ncbi.nlm.nih.gov/pubmed/28808365 http://dx.doi.org/10.4103/ijccm.IJCCM_426_16 |
work_keys_str_mv | AT haddavijay intraandinterobserverreliabilityofquadricepsmusclethicknessmeasuredwithbedsideultrasonographybycriticalcarephysicians AT khilnanigopic intraandinterobserverreliabilityofquadricepsmusclethicknessmeasuredwithbedsideultrasonographybycriticalcarephysicians AT kumarrohit intraandinterobserverreliabilityofquadricepsmusclethicknessmeasuredwithbedsideultrasonographybycriticalcarephysicians AT dhungunaashesh intraandinterobserverreliabilityofquadricepsmusclethicknessmeasuredwithbedsideultrasonographybycriticalcarephysicians AT mittalsaurabh intraandinterobserverreliabilityofquadricepsmusclethicknessmeasuredwithbedsideultrasonographybycriticalcarephysicians AT khanmaroofahmad intraandinterobserverreliabilityofquadricepsmusclethicknessmeasuredwithbedsideultrasonographybycriticalcarephysicians AT madankaran intraandinterobserverreliabilityofquadricepsmusclethicknessmeasuredwithbedsideultrasonographybycriticalcarephysicians AT mohananant intraandinterobserverreliabilityofquadricepsmusclethicknessmeasuredwithbedsideultrasonographybycriticalcarephysicians AT guleriarandeep intraandinterobserverreliabilityofquadricepsmusclethicknessmeasuredwithbedsideultrasonographybycriticalcarephysicians |