Cargando…

Intra- and Inter-observer Reliability of Quadriceps Muscle Thickness Measured with Bedside Ultrasonography by Critical Care Physicians

BACKGROUND: Muscle wasting is common among critically ill patients with sepsis and has a significant effect on clinical outcome. However, appropriate tool for measurement of muscle loss is debatable. Ultrasonography (USG) has been used for objective assessment of quadriceps muscle thickness among th...

Descripción completa

Detalles Bibliográficos
Autores principales: Hadda, Vijay, Khilnani, Gopi C., Kumar, Rohit, Dhunguna, Ashesh, Mittal, Saurabh, Khan, Maroof Ahmad, Madan, Karan, Mohan, Anant, Guleria, Randeep
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5538093/
https://www.ncbi.nlm.nih.gov/pubmed/28808365
http://dx.doi.org/10.4103/ijccm.IJCCM_426_16
_version_ 1783254302550130688
author Hadda, Vijay
Khilnani, Gopi C.
Kumar, Rohit
Dhunguna, Ashesh
Mittal, Saurabh
Khan, Maroof Ahmad
Madan, Karan
Mohan, Anant
Guleria, Randeep
author_facet Hadda, Vijay
Khilnani, Gopi C.
Kumar, Rohit
Dhunguna, Ashesh
Mittal, Saurabh
Khan, Maroof Ahmad
Madan, Karan
Mohan, Anant
Guleria, Randeep
author_sort Hadda, Vijay
collection PubMed
description BACKGROUND: Muscle wasting is common among critically ill patients with sepsis and has a significant effect on clinical outcome. However, appropriate tool for measurement of muscle loss is debatable. Ultrasonography (USG) has been used for objective assessment of quadriceps muscle thickness among these patients; however, there is limited data on its reliability. AIMS AND OBJECTIVE: This study was aimed to assess the reliability of quadriceps muscle thickness as measured by critical care physicians. METHODOLOGY: This cross-sectional study included twenty patients with sepsis. Quadriceps muscle thickness was measured on right mid-thigh at a predefined point by two critical care fellows using bedside USG. Intra- and inter-observer reliability of the measurements was assessed by intra-class correlation coefficient (ICC). RESULTS: Hundred and twenty quadriceps muscle thickness measurements, three by each of the two critical care fellows, were done in twenty patients with sepsis. First, second, and third measurements (mean ± standard deviation) taken by the first observer (RK) were 35.030 ± 3.546 mm, 35.055 ± 3.307 mm, and 35.245 ± 3.027 mm, respectively. The three values recorded by the second observer (AD) were 35.585 ± 3.746 mm, 35.1 ± 3.006 mm, and 34.89 ± 2.556 mm, respectively. ICC for observer 1 and 2 was 0.925 (95% confidence interval [CI]: 0.851–0.967) and 0.835 (95% CI: 0.689–0.925), respectively. The mean difference of measurement between two observers was 0.082 mm (95% CI: −1.194–1.031). The mean ICC (95% CI) for inter-observer reliability was 0.992 (0.979–0.997); P < 0.001. CONCLUSIONS: This study shows that ultrasound is a reliable tool for the measurement of quadriceps muscle thickness by critical care physicians with excellent inter- and intra-class reliability.
format Online
Article
Text
id pubmed-5538093
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-55380932017-08-14 Intra- and Inter-observer Reliability of Quadriceps Muscle Thickness Measured with Bedside Ultrasonography by Critical Care Physicians Hadda, Vijay Khilnani, Gopi C. Kumar, Rohit Dhunguna, Ashesh Mittal, Saurabh Khan, Maroof Ahmad Madan, Karan Mohan, Anant Guleria, Randeep Indian J Crit Care Med Research Article BACKGROUND: Muscle wasting is common among critically ill patients with sepsis and has a significant effect on clinical outcome. However, appropriate tool for measurement of muscle loss is debatable. Ultrasonography (USG) has been used for objective assessment of quadriceps muscle thickness among these patients; however, there is limited data on its reliability. AIMS AND OBJECTIVE: This study was aimed to assess the reliability of quadriceps muscle thickness as measured by critical care physicians. METHODOLOGY: This cross-sectional study included twenty patients with sepsis. Quadriceps muscle thickness was measured on right mid-thigh at a predefined point by two critical care fellows using bedside USG. Intra- and inter-observer reliability of the measurements was assessed by intra-class correlation coefficient (ICC). RESULTS: Hundred and twenty quadriceps muscle thickness measurements, three by each of the two critical care fellows, were done in twenty patients with sepsis. First, second, and third measurements (mean ± standard deviation) taken by the first observer (RK) were 35.030 ± 3.546 mm, 35.055 ± 3.307 mm, and 35.245 ± 3.027 mm, respectively. The three values recorded by the second observer (AD) were 35.585 ± 3.746 mm, 35.1 ± 3.006 mm, and 34.89 ± 2.556 mm, respectively. ICC for observer 1 and 2 was 0.925 (95% confidence interval [CI]: 0.851–0.967) and 0.835 (95% CI: 0.689–0.925), respectively. The mean difference of measurement between two observers was 0.082 mm (95% CI: −1.194–1.031). The mean ICC (95% CI) for inter-observer reliability was 0.992 (0.979–0.997); P < 0.001. CONCLUSIONS: This study shows that ultrasound is a reliable tool for the measurement of quadriceps muscle thickness by critical care physicians with excellent inter- and intra-class reliability. Medknow Publications & Media Pvt Ltd 2017-07 /pmc/articles/PMC5538093/ /pubmed/28808365 http://dx.doi.org/10.4103/ijccm.IJCCM_426_16 Text en Copyright: © 2017 Indian Journal of Critical Care Medicine http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Research Article
Hadda, Vijay
Khilnani, Gopi C.
Kumar, Rohit
Dhunguna, Ashesh
Mittal, Saurabh
Khan, Maroof Ahmad
Madan, Karan
Mohan, Anant
Guleria, Randeep
Intra- and Inter-observer Reliability of Quadriceps Muscle Thickness Measured with Bedside Ultrasonography by Critical Care Physicians
title Intra- and Inter-observer Reliability of Quadriceps Muscle Thickness Measured with Bedside Ultrasonography by Critical Care Physicians
title_full Intra- and Inter-observer Reliability of Quadriceps Muscle Thickness Measured with Bedside Ultrasonography by Critical Care Physicians
title_fullStr Intra- and Inter-observer Reliability of Quadriceps Muscle Thickness Measured with Bedside Ultrasonography by Critical Care Physicians
title_full_unstemmed Intra- and Inter-observer Reliability of Quadriceps Muscle Thickness Measured with Bedside Ultrasonography by Critical Care Physicians
title_short Intra- and Inter-observer Reliability of Quadriceps Muscle Thickness Measured with Bedside Ultrasonography by Critical Care Physicians
title_sort intra- and inter-observer reliability of quadriceps muscle thickness measured with bedside ultrasonography by critical care physicians
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5538093/
https://www.ncbi.nlm.nih.gov/pubmed/28808365
http://dx.doi.org/10.4103/ijccm.IJCCM_426_16
work_keys_str_mv AT haddavijay intraandinterobserverreliabilityofquadricepsmusclethicknessmeasuredwithbedsideultrasonographybycriticalcarephysicians
AT khilnanigopic intraandinterobserverreliabilityofquadricepsmusclethicknessmeasuredwithbedsideultrasonographybycriticalcarephysicians
AT kumarrohit intraandinterobserverreliabilityofquadricepsmusclethicknessmeasuredwithbedsideultrasonographybycriticalcarephysicians
AT dhungunaashesh intraandinterobserverreliabilityofquadricepsmusclethicknessmeasuredwithbedsideultrasonographybycriticalcarephysicians
AT mittalsaurabh intraandinterobserverreliabilityofquadricepsmusclethicknessmeasuredwithbedsideultrasonographybycriticalcarephysicians
AT khanmaroofahmad intraandinterobserverreliabilityofquadricepsmusclethicknessmeasuredwithbedsideultrasonographybycriticalcarephysicians
AT madankaran intraandinterobserverreliabilityofquadricepsmusclethicknessmeasuredwithbedsideultrasonographybycriticalcarephysicians
AT mohananant intraandinterobserverreliabilityofquadricepsmusclethicknessmeasuredwithbedsideultrasonographybycriticalcarephysicians
AT guleriarandeep intraandinterobserverreliabilityofquadricepsmusclethicknessmeasuredwithbedsideultrasonographybycriticalcarephysicians