Cargando…

Accuracy of B-scan ultrasonography in acute fundus obscuring vitreous hemorrhage using a standardized scanning protocol and a dedicated ophthalmic ultrasonographer

PURPOSE: To assess the accuracy of B-scan ultrasound (U/S) in diagnosing cases of acute fundus obscuring vitreous hemorrhage (FOVH) using a standardized scan protocol and dedicated ophthalmic ultrasonographer. METHODS: Consecutive patients presenting with acute FOVH of unknown cause, between January...

Descripción completa

Detalles Bibliográficos
Autores principales: Sandinha, Maria T, Kotagiri, Ajay K, Owen, Rona I, Geenen, Caspar, Steel, David HW
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5538682/
https://www.ncbi.nlm.nih.gov/pubmed/28794614
http://dx.doi.org/10.2147/OPTH.S133938
_version_ 1783254386385879040
author Sandinha, Maria T
Kotagiri, Ajay K
Owen, Rona I
Geenen, Caspar
Steel, David HW
author_facet Sandinha, Maria T
Kotagiri, Ajay K
Owen, Rona I
Geenen, Caspar
Steel, David HW
author_sort Sandinha, Maria T
collection PubMed
description PURPOSE: To assess the accuracy of B-scan ultrasound (U/S) in diagnosing cases of acute fundus obscuring vitreous hemorrhage (FOVH) using a standardized scan protocol and dedicated ophthalmic ultrasonographer. METHODS: Consecutive patients presenting with acute FOVH of unknown cause, between January 2013 and December 2014, were prospectively recruited. Patients underwent a scan performed by a dedicated ultrasonographer, utilizing a systematic scan sequence and using an ocular specific U/S device. The U/S findings were compared to the findings during vitrectomy or after spontaneous hemorrhage clearance. RESULTS: Fifty-eight eyes (58 patients) were included. An underlying rhegmatogenous retinal detachment (RRD) and retinal tears without RRD were reported in nine and 14 patients, respectively. Nineteen of these patients underwent vitrectomy, and the other four underwent laser retinopexy or cryopexy alone. An additional six patients with suspected but uncertain retinal tears underwent vitrectomy, during which tears were confirmed in three, two had retinal vessel avulsions, and one had retinal new vessels. There was “complete” agreement between the B-scan findings and clinical findings in 78% of patients, “partial” agreement in 19%, and agreement was not tested in 3%. When the agreement was “partial”, the disagreements did not affect patient management. The sensitivity was 100% for the detection of RRD, and for the detection of new retinal tears in patients without retinal detachment. CONCLUSION: B-scan U/S scan was highly sensitive in identifying the pathology in acute FOVH. Our results show an improvement from previously reported results, likely related to the standardized scan protocol and dedicated ophthalmic ultrasonographer.
format Online
Article
Text
id pubmed-5538682
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-55386822017-08-09 Accuracy of B-scan ultrasonography in acute fundus obscuring vitreous hemorrhage using a standardized scanning protocol and a dedicated ophthalmic ultrasonographer Sandinha, Maria T Kotagiri, Ajay K Owen, Rona I Geenen, Caspar Steel, David HW Clin Ophthalmol Original Research PURPOSE: To assess the accuracy of B-scan ultrasound (U/S) in diagnosing cases of acute fundus obscuring vitreous hemorrhage (FOVH) using a standardized scan protocol and dedicated ophthalmic ultrasonographer. METHODS: Consecutive patients presenting with acute FOVH of unknown cause, between January 2013 and December 2014, were prospectively recruited. Patients underwent a scan performed by a dedicated ultrasonographer, utilizing a systematic scan sequence and using an ocular specific U/S device. The U/S findings were compared to the findings during vitrectomy or after spontaneous hemorrhage clearance. RESULTS: Fifty-eight eyes (58 patients) were included. An underlying rhegmatogenous retinal detachment (RRD) and retinal tears without RRD were reported in nine and 14 patients, respectively. Nineteen of these patients underwent vitrectomy, and the other four underwent laser retinopexy or cryopexy alone. An additional six patients with suspected but uncertain retinal tears underwent vitrectomy, during which tears were confirmed in three, two had retinal vessel avulsions, and one had retinal new vessels. There was “complete” agreement between the B-scan findings and clinical findings in 78% of patients, “partial” agreement in 19%, and agreement was not tested in 3%. When the agreement was “partial”, the disagreements did not affect patient management. The sensitivity was 100% for the detection of RRD, and for the detection of new retinal tears in patients without retinal detachment. CONCLUSION: B-scan U/S scan was highly sensitive in identifying the pathology in acute FOVH. Our results show an improvement from previously reported results, likely related to the standardized scan protocol and dedicated ophthalmic ultrasonographer. Dove Medical Press 2017-07-27 /pmc/articles/PMC5538682/ /pubmed/28794614 http://dx.doi.org/10.2147/OPTH.S133938 Text en © 2017 Sandinha et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Sandinha, Maria T
Kotagiri, Ajay K
Owen, Rona I
Geenen, Caspar
Steel, David HW
Accuracy of B-scan ultrasonography in acute fundus obscuring vitreous hemorrhage using a standardized scanning protocol and a dedicated ophthalmic ultrasonographer
title Accuracy of B-scan ultrasonography in acute fundus obscuring vitreous hemorrhage using a standardized scanning protocol and a dedicated ophthalmic ultrasonographer
title_full Accuracy of B-scan ultrasonography in acute fundus obscuring vitreous hemorrhage using a standardized scanning protocol and a dedicated ophthalmic ultrasonographer
title_fullStr Accuracy of B-scan ultrasonography in acute fundus obscuring vitreous hemorrhage using a standardized scanning protocol and a dedicated ophthalmic ultrasonographer
title_full_unstemmed Accuracy of B-scan ultrasonography in acute fundus obscuring vitreous hemorrhage using a standardized scanning protocol and a dedicated ophthalmic ultrasonographer
title_short Accuracy of B-scan ultrasonography in acute fundus obscuring vitreous hemorrhage using a standardized scanning protocol and a dedicated ophthalmic ultrasonographer
title_sort accuracy of b-scan ultrasonography in acute fundus obscuring vitreous hemorrhage using a standardized scanning protocol and a dedicated ophthalmic ultrasonographer
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5538682/
https://www.ncbi.nlm.nih.gov/pubmed/28794614
http://dx.doi.org/10.2147/OPTH.S133938
work_keys_str_mv AT sandinhamariat accuracyofbscanultrasonographyinacutefundusobscuringvitreoushemorrhageusingastandardizedscanningprotocolandadedicatedophthalmicultrasonographer
AT kotagiriajayk accuracyofbscanultrasonographyinacutefundusobscuringvitreoushemorrhageusingastandardizedscanningprotocolandadedicatedophthalmicultrasonographer
AT owenronai accuracyofbscanultrasonographyinacutefundusobscuringvitreoushemorrhageusingastandardizedscanningprotocolandadedicatedophthalmicultrasonographer
AT geenencaspar accuracyofbscanultrasonographyinacutefundusobscuringvitreoushemorrhageusingastandardizedscanningprotocolandadedicatedophthalmicultrasonographer
AT steeldavidhw accuracyofbscanultrasonographyinacutefundusobscuringvitreoushemorrhageusingastandardizedscanningprotocolandadedicatedophthalmicultrasonographer