Cargando…
A Linear Birefringence Measurement Method for an Optical Fiber Current Sensor
In this work, a linear birefringence measurement method is proposed for an optical fiber current sensor (OFCS). First, the optical configuration of the measurement system is presented. Then, the elimination method of the effect of the azimuth angles between the sensing fiber and the two polarizers i...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5539662/ https://www.ncbi.nlm.nih.gov/pubmed/28671621 http://dx.doi.org/10.3390/s17071556 |
_version_ | 1783254522966048768 |
---|---|
author | Xu, Shaoyi Shao, Haiming Li, Chuansheng Xing, Fangfang Wang, Yuqiao Li, Wei |
author_facet | Xu, Shaoyi Shao, Haiming Li, Chuansheng Xing, Fangfang Wang, Yuqiao Li, Wei |
author_sort | Xu, Shaoyi |
collection | PubMed |
description | In this work, a linear birefringence measurement method is proposed for an optical fiber current sensor (OFCS). First, the optical configuration of the measurement system is presented. Then, the elimination method of the effect of the azimuth angles between the sensing fiber and the two polarizers is demonstrated. Moreover, the relationship of the linear birefringence, the Faraday rotation angle and the final output is determined. On these bases, the multi-valued problem on the linear birefringence is simulated and its solution is illustrated when the linear birefringence is unknown. Finally, the experiments are conducted to prove the feasibility of the proposed method. When the numbers of turns of the sensing fiber in the OFCS are about 15, 19, 23, 27, 31, 35, and 39, the measured linear birefringence obtained by the proposed method are about 1.3577, 1.8425, 2.0983, 2.5914, 2.7891, 3.2003 and 3.5198 rad. Two typical methods provide the references for the proposed method. The proposed method is proven to be suitable for the linear birefringence measurement in the full range without the limitation that the linear birefringence must be smaller than π/2. |
format | Online Article Text |
id | pubmed-5539662 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-55396622017-08-11 A Linear Birefringence Measurement Method for an Optical Fiber Current Sensor Xu, Shaoyi Shao, Haiming Li, Chuansheng Xing, Fangfang Wang, Yuqiao Li, Wei Sensors (Basel) Article In this work, a linear birefringence measurement method is proposed for an optical fiber current sensor (OFCS). First, the optical configuration of the measurement system is presented. Then, the elimination method of the effect of the azimuth angles between the sensing fiber and the two polarizers is demonstrated. Moreover, the relationship of the linear birefringence, the Faraday rotation angle and the final output is determined. On these bases, the multi-valued problem on the linear birefringence is simulated and its solution is illustrated when the linear birefringence is unknown. Finally, the experiments are conducted to prove the feasibility of the proposed method. When the numbers of turns of the sensing fiber in the OFCS are about 15, 19, 23, 27, 31, 35, and 39, the measured linear birefringence obtained by the proposed method are about 1.3577, 1.8425, 2.0983, 2.5914, 2.7891, 3.2003 and 3.5198 rad. Two typical methods provide the references for the proposed method. The proposed method is proven to be suitable for the linear birefringence measurement in the full range without the limitation that the linear birefringence must be smaller than π/2. MDPI 2017-07-03 /pmc/articles/PMC5539662/ /pubmed/28671621 http://dx.doi.org/10.3390/s17071556 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Xu, Shaoyi Shao, Haiming Li, Chuansheng Xing, Fangfang Wang, Yuqiao Li, Wei A Linear Birefringence Measurement Method for an Optical Fiber Current Sensor |
title | A Linear Birefringence Measurement Method for an Optical Fiber Current Sensor |
title_full | A Linear Birefringence Measurement Method for an Optical Fiber Current Sensor |
title_fullStr | A Linear Birefringence Measurement Method for an Optical Fiber Current Sensor |
title_full_unstemmed | A Linear Birefringence Measurement Method for an Optical Fiber Current Sensor |
title_short | A Linear Birefringence Measurement Method for an Optical Fiber Current Sensor |
title_sort | linear birefringence measurement method for an optical fiber current sensor |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5539662/ https://www.ncbi.nlm.nih.gov/pubmed/28671621 http://dx.doi.org/10.3390/s17071556 |
work_keys_str_mv | AT xushaoyi alinearbirefringencemeasurementmethodforanopticalfibercurrentsensor AT shaohaiming alinearbirefringencemeasurementmethodforanopticalfibercurrentsensor AT lichuansheng alinearbirefringencemeasurementmethodforanopticalfibercurrentsensor AT xingfangfang alinearbirefringencemeasurementmethodforanopticalfibercurrentsensor AT wangyuqiao alinearbirefringencemeasurementmethodforanopticalfibercurrentsensor AT liwei alinearbirefringencemeasurementmethodforanopticalfibercurrentsensor AT xushaoyi linearbirefringencemeasurementmethodforanopticalfibercurrentsensor AT shaohaiming linearbirefringencemeasurementmethodforanopticalfibercurrentsensor AT lichuansheng linearbirefringencemeasurementmethodforanopticalfibercurrentsensor AT xingfangfang linearbirefringencemeasurementmethodforanopticalfibercurrentsensor AT wangyuqiao linearbirefringencemeasurementmethodforanopticalfibercurrentsensor AT liwei linearbirefringencemeasurementmethodforanopticalfibercurrentsensor |