Cargando…

Measurement of fractionated plasma metanephrines for exclusion of pheochromocytoma: Can specificity be improved by adjustment for age?

BACKGROUND: Biochemical testing for pheochromocytoma by measurement of fractionated plasma metanephrines is limited by false positive rates of up to 18% in people without known genetic predisposition to the disease. The plasma normetanephrine fraction is responsible for most false positives and plas...

Descripción completa

Detalles Bibliográficos
Autores principales: Sawka, Anna M, Thabane, Lehana, Gafni, Amiram, Levine, Mitchell, Young, William F
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2005
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC553971/
https://www.ncbi.nlm.nih.gov/pubmed/15737232
http://dx.doi.org/10.1186/1472-6823-5-1
_version_ 1782122493414211584
author Sawka, Anna M
Thabane, Lehana
Gafni, Amiram
Levine, Mitchell
Young, William F
author_facet Sawka, Anna M
Thabane, Lehana
Gafni, Amiram
Levine, Mitchell
Young, William F
author_sort Sawka, Anna M
collection PubMed
description BACKGROUND: Biochemical testing for pheochromocytoma by measurement of fractionated plasma metanephrines is limited by false positive rates of up to 18% in people without known genetic predisposition to the disease. The plasma normetanephrine fraction is responsible for most false positives and plasma normetanephrine increases with age. The objective of this study was to determine if we could improve the specificity of fractionated plasma measurements, by statistically adjusting for age. METHODS: An age-adjusted metanephrine score was derived using logistic regression from 343 subjects (including 33 people with pheochromocytoma) who underwent fractionated plasma metanephrine measurements as part of investigations for suspected pheochromocytoma at Mayo Clinic Rochester (derivation set). The performance of the age-adjusted score was validated in a dataset of 158 subjects (including patients 23 with pheochromocytoma) that underwent measurements of fractionated plasma metanephrines at Mayo Clinic the following year (validation dataset). None of the participants in the validation dataset had known genetic predisposition to pheochromocytoma. RESULTS: The sensitivity of the age-adjusted metanephrine score was the same as that of traditional interpretation of fractionated plasma metanephrine measurements, yielding a sensitivity of 100% (23/23, 95% confidence interval [CI] 85.7%, 100%). However, the false positive rate with traditional interpretation of fractionated plasma metanephrine measurements was 16.3% (22/135, 95% CI, 11.0%, 23.4%) and that of the age-adjusted score was significantly lower at 3.0% (4/135, 95% CI, 1.2%, 7.4%) (p < 0.001 using McNemar's test). CONCLUSION: An adjustment for age in the interpretation of results of fractionated plasma metanephrines may significantly decrease false positives when using this test to exclude sporadic pheochromocytoma. Such improvements in false positive rate may result in savings of expenditures related to confirmatory imaging.
format Text
id pubmed-553971
institution National Center for Biotechnology Information
language English
publishDate 2005
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-5539712005-03-11 Measurement of fractionated plasma metanephrines for exclusion of pheochromocytoma: Can specificity be improved by adjustment for age? Sawka, Anna M Thabane, Lehana Gafni, Amiram Levine, Mitchell Young, William F BMC Endocr Disord Research Article BACKGROUND: Biochemical testing for pheochromocytoma by measurement of fractionated plasma metanephrines is limited by false positive rates of up to 18% in people without known genetic predisposition to the disease. The plasma normetanephrine fraction is responsible for most false positives and plasma normetanephrine increases with age. The objective of this study was to determine if we could improve the specificity of fractionated plasma measurements, by statistically adjusting for age. METHODS: An age-adjusted metanephrine score was derived using logistic regression from 343 subjects (including 33 people with pheochromocytoma) who underwent fractionated plasma metanephrine measurements as part of investigations for suspected pheochromocytoma at Mayo Clinic Rochester (derivation set). The performance of the age-adjusted score was validated in a dataset of 158 subjects (including patients 23 with pheochromocytoma) that underwent measurements of fractionated plasma metanephrines at Mayo Clinic the following year (validation dataset). None of the participants in the validation dataset had known genetic predisposition to pheochromocytoma. RESULTS: The sensitivity of the age-adjusted metanephrine score was the same as that of traditional interpretation of fractionated plasma metanephrine measurements, yielding a sensitivity of 100% (23/23, 95% confidence interval [CI] 85.7%, 100%). However, the false positive rate with traditional interpretation of fractionated plasma metanephrine measurements was 16.3% (22/135, 95% CI, 11.0%, 23.4%) and that of the age-adjusted score was significantly lower at 3.0% (4/135, 95% CI, 1.2%, 7.4%) (p < 0.001 using McNemar's test). CONCLUSION: An adjustment for age in the interpretation of results of fractionated plasma metanephrines may significantly decrease false positives when using this test to exclude sporadic pheochromocytoma. Such improvements in false positive rate may result in savings of expenditures related to confirmatory imaging. BioMed Central 2005-02-28 /pmc/articles/PMC553971/ /pubmed/15737232 http://dx.doi.org/10.1186/1472-6823-5-1 Text en Copyright © 2005 Sawka et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Sawka, Anna M
Thabane, Lehana
Gafni, Amiram
Levine, Mitchell
Young, William F
Measurement of fractionated plasma metanephrines for exclusion of pheochromocytoma: Can specificity be improved by adjustment for age?
title Measurement of fractionated plasma metanephrines for exclusion of pheochromocytoma: Can specificity be improved by adjustment for age?
title_full Measurement of fractionated plasma metanephrines for exclusion of pheochromocytoma: Can specificity be improved by adjustment for age?
title_fullStr Measurement of fractionated plasma metanephrines for exclusion of pheochromocytoma: Can specificity be improved by adjustment for age?
title_full_unstemmed Measurement of fractionated plasma metanephrines for exclusion of pheochromocytoma: Can specificity be improved by adjustment for age?
title_short Measurement of fractionated plasma metanephrines for exclusion of pheochromocytoma: Can specificity be improved by adjustment for age?
title_sort measurement of fractionated plasma metanephrines for exclusion of pheochromocytoma: can specificity be improved by adjustment for age?
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC553971/
https://www.ncbi.nlm.nih.gov/pubmed/15737232
http://dx.doi.org/10.1186/1472-6823-5-1
work_keys_str_mv AT sawkaannam measurementoffractionatedplasmametanephrinesforexclusionofpheochromocytomacanspecificitybeimprovedbyadjustmentforage
AT thabanelehana measurementoffractionatedplasmametanephrinesforexclusionofpheochromocytomacanspecificitybeimprovedbyadjustmentforage
AT gafniamiram measurementoffractionatedplasmametanephrinesforexclusionofpheochromocytomacanspecificitybeimprovedbyadjustmentforage
AT levinemitchell measurementoffractionatedplasmametanephrinesforexclusionofpheochromocytomacanspecificitybeimprovedbyadjustmentforage
AT youngwilliamf measurementoffractionatedplasmametanephrinesforexclusionofpheochromocytomacanspecificitybeimprovedbyadjustmentforage