A Pulse Rate Detection Method for Mouse Application Based on Multi-PPG Sensors
Heart rate is an important physiological parameter for healthcare. Among measurement methods, photoplethysmography (PPG) is an easy and convenient method for pulse rate detection. However, as the PPG signal faces the challenge of motion artifacts and is constrained by the position chosen, the purpos...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5539748/ https://www.ncbi.nlm.nih.gov/pubmed/28708112 http://dx.doi.org/10.3390/s17071628 |
_version_ | 1783254541200785408 |
---|---|
author | Lin, Shu-Tyng Chen, Wei-Hao Lin, Yuan-Hsiang |
author_facet | Lin, Shu-Tyng Chen, Wei-Hao Lin, Yuan-Hsiang |
author_sort | Lin, Shu-Tyng |
collection | PubMed |
description | Heart rate is an important physiological parameter for healthcare. Among measurement methods, photoplethysmography (PPG) is an easy and convenient method for pulse rate detection. However, as the PPG signal faces the challenge of motion artifacts and is constrained by the position chosen, the purpose of this paper is to implement a comfortable and easy-to-use multi-PPG sensor module combined with a stable and accurate real-time pulse rate detection method on a computer mouse. A weighted average method for multi-PPG sensors is used to adjust the weight of each signal channel in order to raise the accuracy and stability of the detected signal, therefore reducing the disturbance of noise under the environment of moving effectively and efficiently. According to the experiment results, the proposed method can increase the usability and probability of PPG signal detection on palms. |
format | Online Article Text |
id | pubmed-5539748 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-55397482017-08-11 A Pulse Rate Detection Method for Mouse Application Based on Multi-PPG Sensors Lin, Shu-Tyng Chen, Wei-Hao Lin, Yuan-Hsiang Sensors (Basel) Article Heart rate is an important physiological parameter for healthcare. Among measurement methods, photoplethysmography (PPG) is an easy and convenient method for pulse rate detection. However, as the PPG signal faces the challenge of motion artifacts and is constrained by the position chosen, the purpose of this paper is to implement a comfortable and easy-to-use multi-PPG sensor module combined with a stable and accurate real-time pulse rate detection method on a computer mouse. A weighted average method for multi-PPG sensors is used to adjust the weight of each signal channel in order to raise the accuracy and stability of the detected signal, therefore reducing the disturbance of noise under the environment of moving effectively and efficiently. According to the experiment results, the proposed method can increase the usability and probability of PPG signal detection on palms. MDPI 2017-07-14 /pmc/articles/PMC5539748/ /pubmed/28708112 http://dx.doi.org/10.3390/s17071628 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lin, Shu-Tyng Chen, Wei-Hao Lin, Yuan-Hsiang A Pulse Rate Detection Method for Mouse Application Based on Multi-PPG Sensors |
title | A Pulse Rate Detection Method for Mouse Application Based on Multi-PPG Sensors |
title_full | A Pulse Rate Detection Method for Mouse Application Based on Multi-PPG Sensors |
title_fullStr | A Pulse Rate Detection Method for Mouse Application Based on Multi-PPG Sensors |
title_full_unstemmed | A Pulse Rate Detection Method for Mouse Application Based on Multi-PPG Sensors |
title_short | A Pulse Rate Detection Method for Mouse Application Based on Multi-PPG Sensors |
title_sort | pulse rate detection method for mouse application based on multi-ppg sensors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5539748/ https://www.ncbi.nlm.nih.gov/pubmed/28708112 http://dx.doi.org/10.3390/s17071628 |
work_keys_str_mv | AT linshutyng apulseratedetectionmethodformouseapplicationbasedonmultippgsensors AT chenweihao apulseratedetectionmethodformouseapplicationbasedonmultippgsensors AT linyuanhsiang apulseratedetectionmethodformouseapplicationbasedonmultippgsensors AT linshutyng pulseratedetectionmethodformouseapplicationbasedonmultippgsensors AT chenweihao pulseratedetectionmethodformouseapplicationbasedonmultippgsensors AT linyuanhsiang pulseratedetectionmethodformouseapplicationbasedonmultippgsensors |