Cargando…
Comparison of low density and high density pedicle screw instrumentation in Lenke 1 adolescent idiopathic scoliosis
BACKGROUND: The correlation between implant density and deformity correction has not yet led to a precise conclusion in adolescent idiopathic scoliosis (AIS). The aim of this study was to evaluate the effects of low density (LD) and high density (HD) pedicle screw instrumentation in terms of the cli...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5541645/ https://www.ncbi.nlm.nih.gov/pubmed/28768503 http://dx.doi.org/10.1186/s12891-017-1695-x |
_version_ | 1783254853804359680 |
---|---|
author | Shen, Mingkui Jiang, Honghui Luo, Ming Wang, Wengang Li, Ning Wang, Lulu Xia, Lei |
author_facet | Shen, Mingkui Jiang, Honghui Luo, Ming Wang, Wengang Li, Ning Wang, Lulu Xia, Lei |
author_sort | Shen, Mingkui |
collection | PubMed |
description | BACKGROUND: The correlation between implant density and deformity correction has not yet led to a precise conclusion in adolescent idiopathic scoliosis (AIS). The aim of this study was to evaluate the effects of low density (LD) and high density (HD) pedicle screw instrumentation in terms of the clinical, radiological and Scoliosis Research Society (SRS)-22 outcomes in Lenke 1 AIS. METHODS: We retrospectively reviewed 62 consecutive Lenke 1 AIS patients who underwent posterior spinal arthrodesis using all-pedicle screw instrumentation with a minimum follow-up of 24 months. The implant density was defined as the number of screws per spinal level fused. Patients were then divided into two groups according to the average implant density for the entire study. The LD group (n = 28) had fewer than 1.61 screws per level, while the HD group (n = 34) had more than 1.61 screws per level. The radiographs were analysed preoperatively, postoperatively and at final follow-up. The perioperative and SRS-22 outcomes were also assessed. Independent sample t tests were used between the two groups. RESULTS: Comparisons between the two groups showed no significant differences in the correction of the main thoracic curve and thoracic kyphosis, blood transfusion, hospital stay, and SRS-22 scores. Compared with the HD group, there was a decreased operating time (278.4 vs. 331.0 min, p = 0.004) and decreased blood loss (823.6 vs. 1010.9 ml, p = 0.048), pedicle screws needed (15.1 vs. 19.6, p < 0.001), and implant costs ($10,191.0 vs. $13,577.3, p = 0.003) in the LD group. CONCLUSIONS: Both low density and high density pedicle screw instrumentation achieved satisfactory deformity correction in Lenke 1 AIS patients. However, the operating time and blood loss were reduced, and the implant costs were decreased with the use of low screw density constructs. |
format | Online Article Text |
id | pubmed-5541645 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-55416452017-08-07 Comparison of low density and high density pedicle screw instrumentation in Lenke 1 adolescent idiopathic scoliosis Shen, Mingkui Jiang, Honghui Luo, Ming Wang, Wengang Li, Ning Wang, Lulu Xia, Lei BMC Musculoskelet Disord Research Article BACKGROUND: The correlation between implant density and deformity correction has not yet led to a precise conclusion in adolescent idiopathic scoliosis (AIS). The aim of this study was to evaluate the effects of low density (LD) and high density (HD) pedicle screw instrumentation in terms of the clinical, radiological and Scoliosis Research Society (SRS)-22 outcomes in Lenke 1 AIS. METHODS: We retrospectively reviewed 62 consecutive Lenke 1 AIS patients who underwent posterior spinal arthrodesis using all-pedicle screw instrumentation with a minimum follow-up of 24 months. The implant density was defined as the number of screws per spinal level fused. Patients were then divided into two groups according to the average implant density for the entire study. The LD group (n = 28) had fewer than 1.61 screws per level, while the HD group (n = 34) had more than 1.61 screws per level. The radiographs were analysed preoperatively, postoperatively and at final follow-up. The perioperative and SRS-22 outcomes were also assessed. Independent sample t tests were used between the two groups. RESULTS: Comparisons between the two groups showed no significant differences in the correction of the main thoracic curve and thoracic kyphosis, blood transfusion, hospital stay, and SRS-22 scores. Compared with the HD group, there was a decreased operating time (278.4 vs. 331.0 min, p = 0.004) and decreased blood loss (823.6 vs. 1010.9 ml, p = 0.048), pedicle screws needed (15.1 vs. 19.6, p < 0.001), and implant costs ($10,191.0 vs. $13,577.3, p = 0.003) in the LD group. CONCLUSIONS: Both low density and high density pedicle screw instrumentation achieved satisfactory deformity correction in Lenke 1 AIS patients. However, the operating time and blood loss were reduced, and the implant costs were decreased with the use of low screw density constructs. BioMed Central 2017-08-02 /pmc/articles/PMC5541645/ /pubmed/28768503 http://dx.doi.org/10.1186/s12891-017-1695-x Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Shen, Mingkui Jiang, Honghui Luo, Ming Wang, Wengang Li, Ning Wang, Lulu Xia, Lei Comparison of low density and high density pedicle screw instrumentation in Lenke 1 adolescent idiopathic scoliosis |
title | Comparison of low density and high density pedicle screw instrumentation in Lenke 1 adolescent idiopathic scoliosis |
title_full | Comparison of low density and high density pedicle screw instrumentation in Lenke 1 adolescent idiopathic scoliosis |
title_fullStr | Comparison of low density and high density pedicle screw instrumentation in Lenke 1 adolescent idiopathic scoliosis |
title_full_unstemmed | Comparison of low density and high density pedicle screw instrumentation in Lenke 1 adolescent idiopathic scoliosis |
title_short | Comparison of low density and high density pedicle screw instrumentation in Lenke 1 adolescent idiopathic scoliosis |
title_sort | comparison of low density and high density pedicle screw instrumentation in lenke 1 adolescent idiopathic scoliosis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5541645/ https://www.ncbi.nlm.nih.gov/pubmed/28768503 http://dx.doi.org/10.1186/s12891-017-1695-x |
work_keys_str_mv | AT shenmingkui comparisonoflowdensityandhighdensitypediclescrewinstrumentationinlenke1adolescentidiopathicscoliosis AT jianghonghui comparisonoflowdensityandhighdensitypediclescrewinstrumentationinlenke1adolescentidiopathicscoliosis AT luoming comparisonoflowdensityandhighdensitypediclescrewinstrumentationinlenke1adolescentidiopathicscoliosis AT wangwengang comparisonoflowdensityandhighdensitypediclescrewinstrumentationinlenke1adolescentidiopathicscoliosis AT lining comparisonoflowdensityandhighdensitypediclescrewinstrumentationinlenke1adolescentidiopathicscoliosis AT wanglulu comparisonoflowdensityandhighdensitypediclescrewinstrumentationinlenke1adolescentidiopathicscoliosis AT xialei comparisonoflowdensityandhighdensitypediclescrewinstrumentationinlenke1adolescentidiopathicscoliosis |