Cargando…
Solidified Floating Organic Drop Microextraction for the Detection of Trace Amount of Lead in Various Samples by Electrothermal Atomic Absorption Spectrometry
A novel method was developed for determination of trace amounts of lead in water and food samples. Solidified floating organic drop microextraction was used to preconcentrate the lead ion. After the analyte was complexed with 1-(2-pyridylazo)-2-naphthol, undecanol and acetonitrile were added as extr...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5541831/ https://www.ncbi.nlm.nih.gov/pubmed/28808599 http://dx.doi.org/10.1155/2017/6268975 |
_version_ | 1783254887323140096 |
---|---|
author | Aydın Urucu, Oya Dönmez, Şeyda Kök Yetimoğlu, Ece |
author_facet | Aydın Urucu, Oya Dönmez, Şeyda Kök Yetimoğlu, Ece |
author_sort | Aydın Urucu, Oya |
collection | PubMed |
description | A novel method was developed for determination of trace amounts of lead in water and food samples. Solidified floating organic drop microextraction was used to preconcentrate the lead ion. After the analyte was complexed with 1-(2-pyridylazo)-2-naphthol, undecanol and acetonitrile were added as extraction and dispersive solvent, respectively. Variables such as pH, volumes of extraction and dispersive solvents, and concentration of chelating agent were optimized. Under the optimum conditions, the detection limit of Pb (II) was determined as 0.042 µg L(−1) with an enrichment factor of 300. The relative standard deviation is <10%. Accuracy of the developed procedure was evaluated by the analysis of certified reference material of human hair (NCS DC 73347) and wastewater (SPS-WW2) with satisfactory results. The developed procedure was then successfully applied to biscuit and water samples for detection of Pb (II) ions. |
format | Online Article Text |
id | pubmed-5541831 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-55418312017-08-14 Solidified Floating Organic Drop Microextraction for the Detection of Trace Amount of Lead in Various Samples by Electrothermal Atomic Absorption Spectrometry Aydın Urucu, Oya Dönmez, Şeyda Kök Yetimoğlu, Ece J Anal Methods Chem Research Article A novel method was developed for determination of trace amounts of lead in water and food samples. Solidified floating organic drop microextraction was used to preconcentrate the lead ion. After the analyte was complexed with 1-(2-pyridylazo)-2-naphthol, undecanol and acetonitrile were added as extraction and dispersive solvent, respectively. Variables such as pH, volumes of extraction and dispersive solvents, and concentration of chelating agent were optimized. Under the optimum conditions, the detection limit of Pb (II) was determined as 0.042 µg L(−1) with an enrichment factor of 300. The relative standard deviation is <10%. Accuracy of the developed procedure was evaluated by the analysis of certified reference material of human hair (NCS DC 73347) and wastewater (SPS-WW2) with satisfactory results. The developed procedure was then successfully applied to biscuit and water samples for detection of Pb (II) ions. Hindawi 2017 2017-07-20 /pmc/articles/PMC5541831/ /pubmed/28808599 http://dx.doi.org/10.1155/2017/6268975 Text en Copyright © 2017 Oya Aydın Urucu et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Aydın Urucu, Oya Dönmez, Şeyda Kök Yetimoğlu, Ece Solidified Floating Organic Drop Microextraction for the Detection of Trace Amount of Lead in Various Samples by Electrothermal Atomic Absorption Spectrometry |
title | Solidified Floating Organic Drop Microextraction for the Detection of Trace Amount of Lead in Various Samples by Electrothermal Atomic Absorption Spectrometry |
title_full | Solidified Floating Organic Drop Microextraction for the Detection of Trace Amount of Lead in Various Samples by Electrothermal Atomic Absorption Spectrometry |
title_fullStr | Solidified Floating Organic Drop Microextraction for the Detection of Trace Amount of Lead in Various Samples by Electrothermal Atomic Absorption Spectrometry |
title_full_unstemmed | Solidified Floating Organic Drop Microextraction for the Detection of Trace Amount of Lead in Various Samples by Electrothermal Atomic Absorption Spectrometry |
title_short | Solidified Floating Organic Drop Microextraction for the Detection of Trace Amount of Lead in Various Samples by Electrothermal Atomic Absorption Spectrometry |
title_sort | solidified floating organic drop microextraction for the detection of trace amount of lead in various samples by electrothermal atomic absorption spectrometry |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5541831/ https://www.ncbi.nlm.nih.gov/pubmed/28808599 http://dx.doi.org/10.1155/2017/6268975 |
work_keys_str_mv | AT aydınurucuoya solidifiedfloatingorganicdropmicroextractionforthedetectionoftraceamountofleadinvarioussamplesbyelectrothermalatomicabsorptionspectrometry AT donmezseyda solidifiedfloatingorganicdropmicroextractionforthedetectionoftraceamountofleadinvarioussamplesbyelectrothermalatomicabsorptionspectrometry AT kokyetimogluece solidifiedfloatingorganicdropmicroextractionforthedetectionoftraceamountofleadinvarioussamplesbyelectrothermalatomicabsorptionspectrometry |