Cargando…
Design and implementation of a BSN-based system for plantar health evaluation with exercise load quantification
BACKGROUND: Plantar pressure measurement has become increasingly useful in the evaluation of plantar health conditions thanks to the recent progression in sensing technology. Due to the large volume and high energy consumption of monitoring devices, traditional systems for plantar pressure measureme...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5543572/ https://www.ncbi.nlm.nih.gov/pubmed/28774311 http://dx.doi.org/10.1186/s12938-017-0389-9 |
_version_ | 1783255170741698560 |
---|---|
author | Wang, Yang Liu, Zhiwen Yang, Jian Ma, Shaodong |
author_facet | Wang, Yang Liu, Zhiwen Yang, Jian Ma, Shaodong |
author_sort | Wang, Yang |
collection | PubMed |
description | BACKGROUND: Plantar pressure measurement has become increasingly useful in the evaluation of plantar health conditions thanks to the recent progression in sensing technology. Due to the large volume and high energy consumption of monitoring devices, traditional systems for plantar pressure measurement are only focused on static or short-term dynamic monitoring. It makes them inappropriate for early detections of plantar symptoms usually presented in long-term activities. METHODS: A prototype of monitoring system based on body sensor network (BSN) is proposed for quantitative assessment of plantar conditions. To further assess the severity of plantar symptoms which can be reflected from the pressure distribution in motion status, an approach to conjoint analysis of pressure distribution and exercise load quantification based on the strike frequency (SF) and heart rate (HR) is also proposed. RESULTS: An examination was tested on 30 subjects to verify the capabilities of the proposed system. The estimated correlation rate with reference devices ([Formula: see text] ) and error rate on the average ([Formula: see text] ) of HR and SF indicated equal measuring capabilities as the existing commercial products . Comprised of the conjoint analysis based on HR and SF, the proposed method of exercise load quantification was examined on all subjects’ recordings. CONCLUSIONS: A prototype of an innovative BSN-based bio-physiological measurement system has been implemented for the long-term monitoring and early evaluation of plantar condition. The experimental results indicated that the proposed system has a great potential value in the applications of long-term plantar health monitoring and evaluation. |
format | Online Article Text |
id | pubmed-5543572 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-55435722017-08-07 Design and implementation of a BSN-based system for plantar health evaluation with exercise load quantification Wang, Yang Liu, Zhiwen Yang, Jian Ma, Shaodong Biomed Eng Online Research BACKGROUND: Plantar pressure measurement has become increasingly useful in the evaluation of plantar health conditions thanks to the recent progression in sensing technology. Due to the large volume and high energy consumption of monitoring devices, traditional systems for plantar pressure measurement are only focused on static or short-term dynamic monitoring. It makes them inappropriate for early detections of plantar symptoms usually presented in long-term activities. METHODS: A prototype of monitoring system based on body sensor network (BSN) is proposed for quantitative assessment of plantar conditions. To further assess the severity of plantar symptoms which can be reflected from the pressure distribution in motion status, an approach to conjoint analysis of pressure distribution and exercise load quantification based on the strike frequency (SF) and heart rate (HR) is also proposed. RESULTS: An examination was tested on 30 subjects to verify the capabilities of the proposed system. The estimated correlation rate with reference devices ([Formula: see text] ) and error rate on the average ([Formula: see text] ) of HR and SF indicated equal measuring capabilities as the existing commercial products . Comprised of the conjoint analysis based on HR and SF, the proposed method of exercise load quantification was examined on all subjects’ recordings. CONCLUSIONS: A prototype of an innovative BSN-based bio-physiological measurement system has been implemented for the long-term monitoring and early evaluation of plantar condition. The experimental results indicated that the proposed system has a great potential value in the applications of long-term plantar health monitoring and evaluation. BioMed Central 2017-08-03 /pmc/articles/PMC5543572/ /pubmed/28774311 http://dx.doi.org/10.1186/s12938-017-0389-9 Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Wang, Yang Liu, Zhiwen Yang, Jian Ma, Shaodong Design and implementation of a BSN-based system for plantar health evaluation with exercise load quantification |
title | Design and implementation of a BSN-based system for plantar health evaluation with exercise load quantification |
title_full | Design and implementation of a BSN-based system for plantar health evaluation with exercise load quantification |
title_fullStr | Design and implementation of a BSN-based system for plantar health evaluation with exercise load quantification |
title_full_unstemmed | Design and implementation of a BSN-based system for plantar health evaluation with exercise load quantification |
title_short | Design and implementation of a BSN-based system for plantar health evaluation with exercise load quantification |
title_sort | design and implementation of a bsn-based system for plantar health evaluation with exercise load quantification |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5543572/ https://www.ncbi.nlm.nih.gov/pubmed/28774311 http://dx.doi.org/10.1186/s12938-017-0389-9 |
work_keys_str_mv | AT wangyang designandimplementationofabsnbasedsystemforplantarhealthevaluationwithexerciseloadquantification AT liuzhiwen designandimplementationofabsnbasedsystemforplantarhealthevaluationwithexerciseloadquantification AT yangjian designandimplementationofabsnbasedsystemforplantarhealthevaluationwithexerciseloadquantification AT mashaodong designandimplementationofabsnbasedsystemforplantarhealthevaluationwithexerciseloadquantification |