Cargando…
Use of endocytoscopy for identification of sessile serrated adenoma/polyps and hyperplastic polyps by quantitative image analysis of the luminal areas
BACKGROUND AND STUDY AIMS: Recent studies that used magnifying chromoendoscopy and endocytoscopy (EC) to investigate endoscopic features of sessile serrated adenoma/polyps (SSA/Ps) suggested that a dilated crypt opening was an important indicator of SSA/Ps. However, no studies to date have measured...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
© Georg Thieme Verlag KG
2017
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5546899/ https://www.ncbi.nlm.nih.gov/pubmed/28791327 http://dx.doi.org/10.1055/s-0043-113562 |
_version_ | 1783255624662908928 |
---|---|
author | Ogawa, Yushi Kudo, Shin-ei Mori, Yuichi Ikehara, Nobunao Maeda, Yasuharu Wakamura, Kunihiko Misawa, Masashi Kudo, Toyoki Hayashi, Takemasa Miyachi, Hideyuki Katagiri, Atsushi Ishida, Fumio Inoue, Haruhiro |
author_facet | Ogawa, Yushi Kudo, Shin-ei Mori, Yuichi Ikehara, Nobunao Maeda, Yasuharu Wakamura, Kunihiko Misawa, Masashi Kudo, Toyoki Hayashi, Takemasa Miyachi, Hideyuki Katagiri, Atsushi Ishida, Fumio Inoue, Haruhiro |
author_sort | Ogawa, Yushi |
collection | PubMed |
description | BACKGROUND AND STUDY AIMS: Recent studies that used magnifying chromoendoscopy and endocytoscopy (EC) to investigate endoscopic features of sessile serrated adenoma/polyps (SSA/Ps) suggested that a dilated crypt opening was an important indicator of SSA/Ps. However, no studies to date have measured the actual extent of dilatation. Hence, we investigated retrospectively the luminal areas using EC to determine a cutoff value for differentiating SSA/Ps from hyperplastic polyps (HPs). PATIENTS AND METHODS : A total of 101 lesions, including 25 SSA/Ps, 66 HPs, and 10 normal mucosal samples, assessed by an integrated-type EC were collected. For each lesion, 1 image that showed the widest lumen was selected and the average area of the contiguous 3 lumens were calculated. The cutoff value differentiating SSAPs from HPs was determined by receiver operating curve (ROC) analysis. RESULTS: The mean luminal areas of SSA/Ps and HPs were 4152 μm (2) and 2117 μm (2) , respectively. ROC analysis found that a luminal area cutoff of 3068 μm (2) had a sensitivity of 80.0 %, a specificity of 77.3 %, an accuracy of 78.0 %, and an area under the ROC curve of 0.865. Furthermore, a cutoff of ≥ 556 μm (2) was found to accurately distinguish between HPs and normal mucosa (sensitivity 98.5 %, specificity 100 %, accuracy 98.7 %, and AUC 0.998). CONCLUSIONS: EC analysis of the luminal area is useful for differentiating between SSAPs and HPs. This approach could be adapted for computer-aided diagnosis of SSA/P. |
format | Online Article Text |
id | pubmed-5546899 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | © Georg Thieme Verlag KG |
record_format | MEDLINE/PubMed |
spelling | pubmed-55468992017-08-08 Use of endocytoscopy for identification of sessile serrated adenoma/polyps and hyperplastic polyps by quantitative image analysis of the luminal areas Ogawa, Yushi Kudo, Shin-ei Mori, Yuichi Ikehara, Nobunao Maeda, Yasuharu Wakamura, Kunihiko Misawa, Masashi Kudo, Toyoki Hayashi, Takemasa Miyachi, Hideyuki Katagiri, Atsushi Ishida, Fumio Inoue, Haruhiro Endosc Int Open BACKGROUND AND STUDY AIMS: Recent studies that used magnifying chromoendoscopy and endocytoscopy (EC) to investigate endoscopic features of sessile serrated adenoma/polyps (SSA/Ps) suggested that a dilated crypt opening was an important indicator of SSA/Ps. However, no studies to date have measured the actual extent of dilatation. Hence, we investigated retrospectively the luminal areas using EC to determine a cutoff value for differentiating SSA/Ps from hyperplastic polyps (HPs). PATIENTS AND METHODS : A total of 101 lesions, including 25 SSA/Ps, 66 HPs, and 10 normal mucosal samples, assessed by an integrated-type EC were collected. For each lesion, 1 image that showed the widest lumen was selected and the average area of the contiguous 3 lumens were calculated. The cutoff value differentiating SSAPs from HPs was determined by receiver operating curve (ROC) analysis. RESULTS: The mean luminal areas of SSA/Ps and HPs were 4152 μm (2) and 2117 μm (2) , respectively. ROC analysis found that a luminal area cutoff of 3068 μm (2) had a sensitivity of 80.0 %, a specificity of 77.3 %, an accuracy of 78.0 %, and an area under the ROC curve of 0.865. Furthermore, a cutoff of ≥ 556 μm (2) was found to accurately distinguish between HPs and normal mucosa (sensitivity 98.5 %, specificity 100 %, accuracy 98.7 %, and AUC 0.998). CONCLUSIONS: EC analysis of the luminal area is useful for differentiating between SSAPs and HPs. This approach could be adapted for computer-aided diagnosis of SSA/P. © Georg Thieme Verlag KG 2017-08 2017-08-07 /pmc/articles/PMC5546899/ /pubmed/28791327 http://dx.doi.org/10.1055/s-0043-113562 Text en © Thieme Medical Publishers |
spellingShingle | Ogawa, Yushi Kudo, Shin-ei Mori, Yuichi Ikehara, Nobunao Maeda, Yasuharu Wakamura, Kunihiko Misawa, Masashi Kudo, Toyoki Hayashi, Takemasa Miyachi, Hideyuki Katagiri, Atsushi Ishida, Fumio Inoue, Haruhiro Use of endocytoscopy for identification of sessile serrated adenoma/polyps and hyperplastic polyps by quantitative image analysis of the luminal areas |
title | Use of endocytoscopy for identification of sessile serrated adenoma/polyps and hyperplastic polyps by quantitative image analysis of the luminal areas |
title_full | Use of endocytoscopy for identification of sessile serrated adenoma/polyps and hyperplastic polyps by quantitative image analysis of the luminal areas |
title_fullStr | Use of endocytoscopy for identification of sessile serrated adenoma/polyps and hyperplastic polyps by quantitative image analysis of the luminal areas |
title_full_unstemmed | Use of endocytoscopy for identification of sessile serrated adenoma/polyps and hyperplastic polyps by quantitative image analysis of the luminal areas |
title_short | Use of endocytoscopy for identification of sessile serrated adenoma/polyps and hyperplastic polyps by quantitative image analysis of the luminal areas |
title_sort | use of endocytoscopy for identification of sessile serrated adenoma/polyps and hyperplastic polyps by quantitative image analysis of the luminal areas |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5546899/ https://www.ncbi.nlm.nih.gov/pubmed/28791327 http://dx.doi.org/10.1055/s-0043-113562 |
work_keys_str_mv | AT ogawayushi useofendocytoscopyforidentificationofsessileserratedadenomapolypsandhyperplasticpolypsbyquantitativeimageanalysisoftheluminalareas AT kudoshinei useofendocytoscopyforidentificationofsessileserratedadenomapolypsandhyperplasticpolypsbyquantitativeimageanalysisoftheluminalareas AT moriyuichi useofendocytoscopyforidentificationofsessileserratedadenomapolypsandhyperplasticpolypsbyquantitativeimageanalysisoftheluminalareas AT ikeharanobunao useofendocytoscopyforidentificationofsessileserratedadenomapolypsandhyperplasticpolypsbyquantitativeimageanalysisoftheluminalareas AT maedayasuharu useofendocytoscopyforidentificationofsessileserratedadenomapolypsandhyperplasticpolypsbyquantitativeimageanalysisoftheluminalareas AT wakamurakunihiko useofendocytoscopyforidentificationofsessileserratedadenomapolypsandhyperplasticpolypsbyquantitativeimageanalysisoftheluminalareas AT misawamasashi useofendocytoscopyforidentificationofsessileserratedadenomapolypsandhyperplasticpolypsbyquantitativeimageanalysisoftheluminalareas AT kudotoyoki useofendocytoscopyforidentificationofsessileserratedadenomapolypsandhyperplasticpolypsbyquantitativeimageanalysisoftheluminalareas AT hayashitakemasa useofendocytoscopyforidentificationofsessileserratedadenomapolypsandhyperplasticpolypsbyquantitativeimageanalysisoftheluminalareas AT miyachihideyuki useofendocytoscopyforidentificationofsessileserratedadenomapolypsandhyperplasticpolypsbyquantitativeimageanalysisoftheluminalareas AT katagiriatsushi useofendocytoscopyforidentificationofsessileserratedadenomapolypsandhyperplasticpolypsbyquantitativeimageanalysisoftheluminalareas AT ishidafumio useofendocytoscopyforidentificationofsessileserratedadenomapolypsandhyperplasticpolypsbyquantitativeimageanalysisoftheluminalareas AT inoueharuhiro useofendocytoscopyforidentificationofsessileserratedadenomapolypsandhyperplasticpolypsbyquantitativeimageanalysisoftheluminalareas |