Cargando…

The diagnostic accuracy of magnetic resonance imaging for anterior cruciate ligament injury in comparison to arthroscopy: a meta-analysis

We performed this meta-analysis to examine the diagnostic accuracy of MRI for the diagnosis of anterior cruciate ligament (ACL) injury in comparison to arthroscopy. We also compared the diagnostic accuracy of MRI with magnetic field intensities (MFI) greater than or equal to 1.5T with those below 1....

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Kun, Du, Jun, Huang, Li-Xin, Ni, Li, Liu, Tao, Yang, Hui-Lin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5548790/
https://www.ncbi.nlm.nih.gov/pubmed/28790406
http://dx.doi.org/10.1038/s41598-017-08133-4
_version_ 1783255878130991104
author Li, Kun
Du, Jun
Huang, Li-Xin
Ni, Li
Liu, Tao
Yang, Hui-Lin
author_facet Li, Kun
Du, Jun
Huang, Li-Xin
Ni, Li
Liu, Tao
Yang, Hui-Lin
author_sort Li, Kun
collection PubMed
description We performed this meta-analysis to examine the diagnostic accuracy of MRI for the diagnosis of anterior cruciate ligament (ACL) injury in comparison to arthroscopy. We also compared the diagnostic accuracy of MRI with magnetic field intensities (MFI) greater than or equal to 1.5T with those below 1.5T, in addition to different MRI sequences. Studies relevant to the diagnosis of ACL injury by MRI and arthroscopy were analyzed. Computer and manual retrieval were carried out on studies published between January 1, 2006 and May 31, 2016. Twenty-one papers were included. Neither threshold nor non-threshold effects were present (p = 0.40, p = 0.06). The pooled sensitivity (SE), specificity (SP), positive likelihood ratio (LR+), negative likelihood ratio (LR−) and diagnostic odds ratio (DOR) with 95% confidence interval (CI) were 87% (84–90%), 90% (88–92%), 6.78 (4.87–9.44), 0.16 (0.13–0.20) and 44.70 (32.34–61.79), respectively. The area under the curve (AUC) was 0.93. The risk of publication bias was negligible (p = 0.75). In conclusion, examination by MRI is able to provide appreciable diagnostic performance. However, the principle, which states that the higher the MFI, the better the diagnostic accuracy, could not be verified. Additionally, conventional sequences (CSs) associated with proton density-weighted imaging (PDWI) are only slightly better than CSs alone, but not statistically different.
format Online
Article
Text
id pubmed-5548790
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-55487902017-08-09 The diagnostic accuracy of magnetic resonance imaging for anterior cruciate ligament injury in comparison to arthroscopy: a meta-analysis Li, Kun Du, Jun Huang, Li-Xin Ni, Li Liu, Tao Yang, Hui-Lin Sci Rep Article We performed this meta-analysis to examine the diagnostic accuracy of MRI for the diagnosis of anterior cruciate ligament (ACL) injury in comparison to arthroscopy. We also compared the diagnostic accuracy of MRI with magnetic field intensities (MFI) greater than or equal to 1.5T with those below 1.5T, in addition to different MRI sequences. Studies relevant to the diagnosis of ACL injury by MRI and arthroscopy were analyzed. Computer and manual retrieval were carried out on studies published between January 1, 2006 and May 31, 2016. Twenty-one papers were included. Neither threshold nor non-threshold effects were present (p = 0.40, p = 0.06). The pooled sensitivity (SE), specificity (SP), positive likelihood ratio (LR+), negative likelihood ratio (LR−) and diagnostic odds ratio (DOR) with 95% confidence interval (CI) were 87% (84–90%), 90% (88–92%), 6.78 (4.87–9.44), 0.16 (0.13–0.20) and 44.70 (32.34–61.79), respectively. The area under the curve (AUC) was 0.93. The risk of publication bias was negligible (p = 0.75). In conclusion, examination by MRI is able to provide appreciable diagnostic performance. However, the principle, which states that the higher the MFI, the better the diagnostic accuracy, could not be verified. Additionally, conventional sequences (CSs) associated with proton density-weighted imaging (PDWI) are only slightly better than CSs alone, but not statistically different. Nature Publishing Group UK 2017-08-08 /pmc/articles/PMC5548790/ /pubmed/28790406 http://dx.doi.org/10.1038/s41598-017-08133-4 Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Li, Kun
Du, Jun
Huang, Li-Xin
Ni, Li
Liu, Tao
Yang, Hui-Lin
The diagnostic accuracy of magnetic resonance imaging for anterior cruciate ligament injury in comparison to arthroscopy: a meta-analysis
title The diagnostic accuracy of magnetic resonance imaging for anterior cruciate ligament injury in comparison to arthroscopy: a meta-analysis
title_full The diagnostic accuracy of magnetic resonance imaging for anterior cruciate ligament injury in comparison to arthroscopy: a meta-analysis
title_fullStr The diagnostic accuracy of magnetic resonance imaging for anterior cruciate ligament injury in comparison to arthroscopy: a meta-analysis
title_full_unstemmed The diagnostic accuracy of magnetic resonance imaging for anterior cruciate ligament injury in comparison to arthroscopy: a meta-analysis
title_short The diagnostic accuracy of magnetic resonance imaging for anterior cruciate ligament injury in comparison to arthroscopy: a meta-analysis
title_sort diagnostic accuracy of magnetic resonance imaging for anterior cruciate ligament injury in comparison to arthroscopy: a meta-analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5548790/
https://www.ncbi.nlm.nih.gov/pubmed/28790406
http://dx.doi.org/10.1038/s41598-017-08133-4
work_keys_str_mv AT likun thediagnosticaccuracyofmagneticresonanceimagingforanteriorcruciateligamentinjuryincomparisontoarthroscopyametaanalysis
AT dujun thediagnosticaccuracyofmagneticresonanceimagingforanteriorcruciateligamentinjuryincomparisontoarthroscopyametaanalysis
AT huanglixin thediagnosticaccuracyofmagneticresonanceimagingforanteriorcruciateligamentinjuryincomparisontoarthroscopyametaanalysis
AT nili thediagnosticaccuracyofmagneticresonanceimagingforanteriorcruciateligamentinjuryincomparisontoarthroscopyametaanalysis
AT liutao thediagnosticaccuracyofmagneticresonanceimagingforanteriorcruciateligamentinjuryincomparisontoarthroscopyametaanalysis
AT yanghuilin thediagnosticaccuracyofmagneticresonanceimagingforanteriorcruciateligamentinjuryincomparisontoarthroscopyametaanalysis
AT likun diagnosticaccuracyofmagneticresonanceimagingforanteriorcruciateligamentinjuryincomparisontoarthroscopyametaanalysis
AT dujun diagnosticaccuracyofmagneticresonanceimagingforanteriorcruciateligamentinjuryincomparisontoarthroscopyametaanalysis
AT huanglixin diagnosticaccuracyofmagneticresonanceimagingforanteriorcruciateligamentinjuryincomparisontoarthroscopyametaanalysis
AT nili diagnosticaccuracyofmagneticresonanceimagingforanteriorcruciateligamentinjuryincomparisontoarthroscopyametaanalysis
AT liutao diagnosticaccuracyofmagneticresonanceimagingforanteriorcruciateligamentinjuryincomparisontoarthroscopyametaanalysis
AT yanghuilin diagnosticaccuracyofmagneticresonanceimagingforanteriorcruciateligamentinjuryincomparisontoarthroscopyametaanalysis