Cargando…
Solving the jitter problem in microwave compressed ultrafast electron diffraction instruments: Robust sub-50 fs cavity-laser phase stabilization
We demonstrate the compression of electron pulses in a high-brightness ultrafast electron diffraction instrument using phase-locked microwave signals directly generated from a mode-locked femtosecond oscillator. Additionally, a continuous-wave phase stabilization system that accurately corrects for...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Crystallographic Association
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5552402/ https://www.ncbi.nlm.nih.gov/pubmed/28852686 http://dx.doi.org/10.1063/1.4989960 |
_version_ | 1783256467201064960 |
---|---|
author | Otto, M. R. René de Cotret, L. P. Stern, M. J. Siwick, B. J. |
author_facet | Otto, M. R. René de Cotret, L. P. Stern, M. J. Siwick, B. J. |
author_sort | Otto, M. R. |
collection | PubMed |
description | We demonstrate the compression of electron pulses in a high-brightness ultrafast electron diffraction instrument using phase-locked microwave signals directly generated from a mode-locked femtosecond oscillator. Additionally, a continuous-wave phase stabilization system that accurately corrects for phase fluctuations arising in the compression cavity from both power amplification and thermal drift induced detuning was designed and implemented. An improvement in the microwave timing stability from 100 fs to 5 fs RMS is measured electronically, and the long-term arrival time stability ([Formula: see text] 10 h) of the electron pulses improves to below our measurement resolution of 50 fs. These results demonstrate sub-relativistic ultrafast electron diffraction with compressed pulses that is no longer limited by laser-microwave synchronization. |
format | Online Article Text |
id | pubmed-5552402 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | American Crystallographic Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-55524022017-08-29 Solving the jitter problem in microwave compressed ultrafast electron diffraction instruments: Robust sub-50 fs cavity-laser phase stabilization Otto, M. R. René de Cotret, L. P. Stern, M. J. Siwick, B. J. Struct Dyn Communications We demonstrate the compression of electron pulses in a high-brightness ultrafast electron diffraction instrument using phase-locked microwave signals directly generated from a mode-locked femtosecond oscillator. Additionally, a continuous-wave phase stabilization system that accurately corrects for phase fluctuations arising in the compression cavity from both power amplification and thermal drift induced detuning was designed and implemented. An improvement in the microwave timing stability from 100 fs to 5 fs RMS is measured electronically, and the long-term arrival time stability ([Formula: see text] 10 h) of the electron pulses improves to below our measurement resolution of 50 fs. These results demonstrate sub-relativistic ultrafast electron diffraction with compressed pulses that is no longer limited by laser-microwave synchronization. American Crystallographic Association 2017-08-02 /pmc/articles/PMC5552402/ /pubmed/28852686 http://dx.doi.org/10.1063/1.4989960 Text en © 2017 Author(s). 2329-7778/2017/4(5)/051101/7 All article content, except where otherwise noted, is licensed under a Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Communications Otto, M. R. René de Cotret, L. P. Stern, M. J. Siwick, B. J. Solving the jitter problem in microwave compressed ultrafast electron diffraction instruments: Robust sub-50 fs cavity-laser phase stabilization |
title | Solving the jitter problem in microwave compressed ultrafast electron diffraction instruments: Robust sub-50 fs cavity-laser phase stabilization |
title_full | Solving the jitter problem in microwave compressed ultrafast electron diffraction instruments: Robust sub-50 fs cavity-laser phase stabilization |
title_fullStr | Solving the jitter problem in microwave compressed ultrafast electron diffraction instruments: Robust sub-50 fs cavity-laser phase stabilization |
title_full_unstemmed | Solving the jitter problem in microwave compressed ultrafast electron diffraction instruments: Robust sub-50 fs cavity-laser phase stabilization |
title_short | Solving the jitter problem in microwave compressed ultrafast electron diffraction instruments: Robust sub-50 fs cavity-laser phase stabilization |
title_sort | solving the jitter problem in microwave compressed ultrafast electron diffraction instruments: robust sub-50 fs cavity-laser phase stabilization |
topic | Communications |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5552402/ https://www.ncbi.nlm.nih.gov/pubmed/28852686 http://dx.doi.org/10.1063/1.4989960 |
work_keys_str_mv | AT ottomr solvingthejitterprobleminmicrowavecompressedultrafastelectrondiffractioninstrumentsrobustsub50fscavitylaserphasestabilization AT renedecotretlp solvingthejitterprobleminmicrowavecompressedultrafastelectrondiffractioninstrumentsrobustsub50fscavitylaserphasestabilization AT sternmj solvingthejitterprobleminmicrowavecompressedultrafastelectrondiffractioninstrumentsrobustsub50fscavitylaserphasestabilization AT siwickbj solvingthejitterprobleminmicrowavecompressedultrafastelectrondiffractioninstrumentsrobustsub50fscavitylaserphasestabilization |