Avoiding Misdiagnosis Due to Antibody Interference with Serum Free Thyroxin
INTRODUCTION: Interfering antibodies are capable of causing potentially misleading results in automated thyroid hormone immunoassays. CASE PRESENTATION: We report the case of a 46- year-old female patient with autoimmune hypothyroidism in chronic replacement treatment with levothyroxine who was pres...
Autores principales: | Beato-Víbora, Pilar I, Alejo-González, S |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Kowsar
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5554610/ https://www.ncbi.nlm.nih.gov/pubmed/28835757 http://dx.doi.org/10.5812/ijem.37792 |
Ejemplares similares
-
Measurement of Serum Free Thyroxine Index May Provide Additional Case Detection Compared to Free Thyroxine in the Diagnosis of Central Hypothyroidism
por: Pantalone, Kevin M., et al.
Publicado: (2015) -
Ureteral carcinoma metastasizing to the testicle: Can misdiagnosis of orchiepididymitis be avoided?
por: Gazouli, Ioanna, et al.
Publicado: (2021) -
New uses and formulations of glucagon for hypoglycaemia
por: Beato-Víbora, Pilar I, et al.
Publicado: (2019) -
False elevation of serum thyroxine in myxoedema due to thyroxine-binding autoantibodies. A diagnostic pitfall.
por: Archbold, G. P., et al.
Publicado: (1986) -
Falsely elevated serum estradiol due to heterophile antibody interference: a case report
por: Atkins, Paul, et al.
Publicado: (2021)