One visualization simulation operation system for distal femoral fracture
A computer-aided 3-dimensional (3D) visualization operation simulation system based on computer-aided design (CAD) Unigraphics NX and Mimics software was established to provide orthopedic surgeons with an actual and reliable system in treating of distal femoral fracture. According to the preoperativ...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5556238/ https://www.ncbi.nlm.nih.gov/pubmed/28796072 http://dx.doi.org/10.1097/MD.0000000000007770 |
_version_ | 1783257031754383360 |
---|---|
author | Wang, Dan Li, Ning Luo, Ming Chen, Yao-kun |
author_facet | Wang, Dan Li, Ning Luo, Ming Chen, Yao-kun |
author_sort | Wang, Dan |
collection | PubMed |
description | A computer-aided 3-dimensional (3D) visualization operation simulation system based on computer-aided design (CAD) Unigraphics NX and Mimics software was established to provide orthopedic surgeons with an actual and reliable system in treating of distal femoral fracture. According to the preoperative CT data, 3D reconstruction of the distal femoral fracture could be achieved by the Mimics software. Then, the CAD Unigraphics NX software was used to measure the model function of all the related surgical instruments, including less invasive stabilization system (LISS) and retrograde intramedullary nail fixation. The function of CAD Unigraphics NX and Mimics software was successful in assisting in the treatment of distal femoral fracture with LISS and retrograde intramedullary nail fixation. The operation procedure was actual, visualized, and lifelike. Moreover, the operation effect could be estimated before surgery. The virtual surgery system may improve the reliability and safety of the operative care of distal femoral fracture. |
format | Online Article Text |
id | pubmed-5556238 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-55562382017-08-25 One visualization simulation operation system for distal femoral fracture Wang, Dan Li, Ning Luo, Ming Chen, Yao-kun Medicine (Baltimore) 7100 A computer-aided 3-dimensional (3D) visualization operation simulation system based on computer-aided design (CAD) Unigraphics NX and Mimics software was established to provide orthopedic surgeons with an actual and reliable system in treating of distal femoral fracture. According to the preoperative CT data, 3D reconstruction of the distal femoral fracture could be achieved by the Mimics software. Then, the CAD Unigraphics NX software was used to measure the model function of all the related surgical instruments, including less invasive stabilization system (LISS) and retrograde intramedullary nail fixation. The function of CAD Unigraphics NX and Mimics software was successful in assisting in the treatment of distal femoral fracture with LISS and retrograde intramedullary nail fixation. The operation procedure was actual, visualized, and lifelike. Moreover, the operation effect could be estimated before surgery. The virtual surgery system may improve the reliability and safety of the operative care of distal femoral fracture. Wolters Kluwer Health 2017-08-11 /pmc/articles/PMC5556238/ /pubmed/28796072 http://dx.doi.org/10.1097/MD.0000000000007770 Text en Copyright © 2017 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0 |
spellingShingle | 7100 Wang, Dan Li, Ning Luo, Ming Chen, Yao-kun One visualization simulation operation system for distal femoral fracture |
title | One visualization simulation operation system for distal femoral fracture |
title_full | One visualization simulation operation system for distal femoral fracture |
title_fullStr | One visualization simulation operation system for distal femoral fracture |
title_full_unstemmed | One visualization simulation operation system for distal femoral fracture |
title_short | One visualization simulation operation system for distal femoral fracture |
title_sort | one visualization simulation operation system for distal femoral fracture |
topic | 7100 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5556238/ https://www.ncbi.nlm.nih.gov/pubmed/28796072 http://dx.doi.org/10.1097/MD.0000000000007770 |
work_keys_str_mv | AT wangdan onevisualizationsimulationoperationsystemfordistalfemoralfracture AT lining onevisualizationsimulationoperationsystemfordistalfemoralfracture AT luoming onevisualizationsimulationoperationsystemfordistalfemoralfracture AT chenyaokun onevisualizationsimulationoperationsystemfordistalfemoralfracture |