Cargando…

Clinical factors related to false-positive rates of patency capsule examination

BACKGROUND: Retention is the most common complication of capsule endoscopy (CE), and is reported to occur in 0–13% of cases. To avoid retention, a PillCam patency capsule (PC) is used in patients with suspected intestinal stenosis. However, a relatively low positive predictive value of the PC examin...

Descripción completa

Detalles Bibliográficos
Autores principales: Sawada, Tsunaki, Nakamura, Masanao, Watanabe, Osamu, Yamamura, Takeshi, Ishikawa, Takuya, Furukawa, Kazuhiro, Funasaka, Kohei, Ohno, Eizaburo, Kawashima, Hiroki, Miyahara, Ryoji, Goto, Hidemi, Hirooka, Yoshiki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5557191/
https://www.ncbi.nlm.nih.gov/pubmed/28835773
http://dx.doi.org/10.1177/1756283X17722744
_version_ 1783257179260715008
author Sawada, Tsunaki
Nakamura, Masanao
Watanabe, Osamu
Yamamura, Takeshi
Ishikawa, Takuya
Furukawa, Kazuhiro
Funasaka, Kohei
Ohno, Eizaburo
Kawashima, Hiroki
Miyahara, Ryoji
Goto, Hidemi
Hirooka, Yoshiki
author_facet Sawada, Tsunaki
Nakamura, Masanao
Watanabe, Osamu
Yamamura, Takeshi
Ishikawa, Takuya
Furukawa, Kazuhiro
Funasaka, Kohei
Ohno, Eizaburo
Kawashima, Hiroki
Miyahara, Ryoji
Goto, Hidemi
Hirooka, Yoshiki
author_sort Sawada, Tsunaki
collection PubMed
description BACKGROUND: Retention is the most common complication of capsule endoscopy (CE), and is reported to occur in 0–13% of cases. To avoid retention, a PillCam patency capsule (PC) is used in patients with suspected intestinal stenosis. However, a relatively low positive predictive value of the PC examination has been reported previously. The aims of this study were to clarify the accuracy of PC examination and to evaluate clinical factors related to cases of false-positive detection. METHODS: We performed a retrospective single-center study of 282 consecutive patients referred for PC examination. Patients in which the PC could not pass through the small bowel within 33 h were classified into the ‘no patency’ group. The ‘no patency’ group was investigated for evidence of significant stenosis upon further examinations, including CE, double-balloon endoscopy, and small bowel follow-through after PC examination. Clinical factors related to small bowel patency and false-positive cases were evaluated. RESULTS: We included 161 male (57.1%) and 121 female (42.9%) patients with a mean age of 47.5 ± 17.7 years. Of the 282 patients enrolled, 27 patients exhibited ‘no patency’ upon PC examination. Multivariate analysis showed that clinical factors related to ‘no patency’ included Crohn’s disease, abdominal symptoms, stenosis upon imaging, and previous abdominal surgery. Upon further examination, nine cases in the ‘no patency’ group had significant stenosis. Sensitivity, specificity, and negative and positive predictive values of PC examination for detecting small bowel stenosis were 93.8%, 96.6%, 99.6%, and 62.5%, respectively, and the only clinical factor related to false-positive cases was constipation (p < 0.05). CONCLUSION: We found a relatively low positive predictive value of PC examination and that constipation was related to false-positive results. To extend the implications of CE indications, clinical study focusing on these results is expected.
format Online
Article
Text
id pubmed-5557191
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-55571912017-08-23 Clinical factors related to false-positive rates of patency capsule examination Sawada, Tsunaki Nakamura, Masanao Watanabe, Osamu Yamamura, Takeshi Ishikawa, Takuya Furukawa, Kazuhiro Funasaka, Kohei Ohno, Eizaburo Kawashima, Hiroki Miyahara, Ryoji Goto, Hidemi Hirooka, Yoshiki Therap Adv Gastroenterol Original Research BACKGROUND: Retention is the most common complication of capsule endoscopy (CE), and is reported to occur in 0–13% of cases. To avoid retention, a PillCam patency capsule (PC) is used in patients with suspected intestinal stenosis. However, a relatively low positive predictive value of the PC examination has been reported previously. The aims of this study were to clarify the accuracy of PC examination and to evaluate clinical factors related to cases of false-positive detection. METHODS: We performed a retrospective single-center study of 282 consecutive patients referred for PC examination. Patients in which the PC could not pass through the small bowel within 33 h were classified into the ‘no patency’ group. The ‘no patency’ group was investigated for evidence of significant stenosis upon further examinations, including CE, double-balloon endoscopy, and small bowel follow-through after PC examination. Clinical factors related to small bowel patency and false-positive cases were evaluated. RESULTS: We included 161 male (57.1%) and 121 female (42.9%) patients with a mean age of 47.5 ± 17.7 years. Of the 282 patients enrolled, 27 patients exhibited ‘no patency’ upon PC examination. Multivariate analysis showed that clinical factors related to ‘no patency’ included Crohn’s disease, abdominal symptoms, stenosis upon imaging, and previous abdominal surgery. Upon further examination, nine cases in the ‘no patency’ group had significant stenosis. Sensitivity, specificity, and negative and positive predictive values of PC examination for detecting small bowel stenosis were 93.8%, 96.6%, 99.6%, and 62.5%, respectively, and the only clinical factor related to false-positive cases was constipation (p < 0.05). CONCLUSION: We found a relatively low positive predictive value of PC examination and that constipation was related to false-positive results. To extend the implications of CE indications, clinical study focusing on these results is expected. SAGE Publications 2017-08-07 2017-08 /pmc/articles/PMC5557191/ /pubmed/28835773 http://dx.doi.org/10.1177/1756283X17722744 Text en © The Author(s), 2017 http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Research
Sawada, Tsunaki
Nakamura, Masanao
Watanabe, Osamu
Yamamura, Takeshi
Ishikawa, Takuya
Furukawa, Kazuhiro
Funasaka, Kohei
Ohno, Eizaburo
Kawashima, Hiroki
Miyahara, Ryoji
Goto, Hidemi
Hirooka, Yoshiki
Clinical factors related to false-positive rates of patency capsule examination
title Clinical factors related to false-positive rates of patency capsule examination
title_full Clinical factors related to false-positive rates of patency capsule examination
title_fullStr Clinical factors related to false-positive rates of patency capsule examination
title_full_unstemmed Clinical factors related to false-positive rates of patency capsule examination
title_short Clinical factors related to false-positive rates of patency capsule examination
title_sort clinical factors related to false-positive rates of patency capsule examination
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5557191/
https://www.ncbi.nlm.nih.gov/pubmed/28835773
http://dx.doi.org/10.1177/1756283X17722744
work_keys_str_mv AT sawadatsunaki clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination
AT nakamuramasanao clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination
AT watanabeosamu clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination
AT yamamuratakeshi clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination
AT ishikawatakuya clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination
AT furukawakazuhiro clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination
AT funasakakohei clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination
AT ohnoeizaburo clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination
AT kawashimahiroki clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination
AT miyahararyoji clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination
AT gotohidemi clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination
AT hirookayoshiki clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination