Cargando…
Clinical factors related to false-positive rates of patency capsule examination
BACKGROUND: Retention is the most common complication of capsule endoscopy (CE), and is reported to occur in 0–13% of cases. To avoid retention, a PillCam patency capsule (PC) is used in patients with suspected intestinal stenosis. However, a relatively low positive predictive value of the PC examin...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5557191/ https://www.ncbi.nlm.nih.gov/pubmed/28835773 http://dx.doi.org/10.1177/1756283X17722744 |
_version_ | 1783257179260715008 |
---|---|
author | Sawada, Tsunaki Nakamura, Masanao Watanabe, Osamu Yamamura, Takeshi Ishikawa, Takuya Furukawa, Kazuhiro Funasaka, Kohei Ohno, Eizaburo Kawashima, Hiroki Miyahara, Ryoji Goto, Hidemi Hirooka, Yoshiki |
author_facet | Sawada, Tsunaki Nakamura, Masanao Watanabe, Osamu Yamamura, Takeshi Ishikawa, Takuya Furukawa, Kazuhiro Funasaka, Kohei Ohno, Eizaburo Kawashima, Hiroki Miyahara, Ryoji Goto, Hidemi Hirooka, Yoshiki |
author_sort | Sawada, Tsunaki |
collection | PubMed |
description | BACKGROUND: Retention is the most common complication of capsule endoscopy (CE), and is reported to occur in 0–13% of cases. To avoid retention, a PillCam patency capsule (PC) is used in patients with suspected intestinal stenosis. However, a relatively low positive predictive value of the PC examination has been reported previously. The aims of this study were to clarify the accuracy of PC examination and to evaluate clinical factors related to cases of false-positive detection. METHODS: We performed a retrospective single-center study of 282 consecutive patients referred for PC examination. Patients in which the PC could not pass through the small bowel within 33 h were classified into the ‘no patency’ group. The ‘no patency’ group was investigated for evidence of significant stenosis upon further examinations, including CE, double-balloon endoscopy, and small bowel follow-through after PC examination. Clinical factors related to small bowel patency and false-positive cases were evaluated. RESULTS: We included 161 male (57.1%) and 121 female (42.9%) patients with a mean age of 47.5 ± 17.7 years. Of the 282 patients enrolled, 27 patients exhibited ‘no patency’ upon PC examination. Multivariate analysis showed that clinical factors related to ‘no patency’ included Crohn’s disease, abdominal symptoms, stenosis upon imaging, and previous abdominal surgery. Upon further examination, nine cases in the ‘no patency’ group had significant stenosis. Sensitivity, specificity, and negative and positive predictive values of PC examination for detecting small bowel stenosis were 93.8%, 96.6%, 99.6%, and 62.5%, respectively, and the only clinical factor related to false-positive cases was constipation (p < 0.05). CONCLUSION: We found a relatively low positive predictive value of PC examination and that constipation was related to false-positive results. To extend the implications of CE indications, clinical study focusing on these results is expected. |
format | Online Article Text |
id | pubmed-5557191 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-55571912017-08-23 Clinical factors related to false-positive rates of patency capsule examination Sawada, Tsunaki Nakamura, Masanao Watanabe, Osamu Yamamura, Takeshi Ishikawa, Takuya Furukawa, Kazuhiro Funasaka, Kohei Ohno, Eizaburo Kawashima, Hiroki Miyahara, Ryoji Goto, Hidemi Hirooka, Yoshiki Therap Adv Gastroenterol Original Research BACKGROUND: Retention is the most common complication of capsule endoscopy (CE), and is reported to occur in 0–13% of cases. To avoid retention, a PillCam patency capsule (PC) is used in patients with suspected intestinal stenosis. However, a relatively low positive predictive value of the PC examination has been reported previously. The aims of this study were to clarify the accuracy of PC examination and to evaluate clinical factors related to cases of false-positive detection. METHODS: We performed a retrospective single-center study of 282 consecutive patients referred for PC examination. Patients in which the PC could not pass through the small bowel within 33 h were classified into the ‘no patency’ group. The ‘no patency’ group was investigated for evidence of significant stenosis upon further examinations, including CE, double-balloon endoscopy, and small bowel follow-through after PC examination. Clinical factors related to small bowel patency and false-positive cases were evaluated. RESULTS: We included 161 male (57.1%) and 121 female (42.9%) patients with a mean age of 47.5 ± 17.7 years. Of the 282 patients enrolled, 27 patients exhibited ‘no patency’ upon PC examination. Multivariate analysis showed that clinical factors related to ‘no patency’ included Crohn’s disease, abdominal symptoms, stenosis upon imaging, and previous abdominal surgery. Upon further examination, nine cases in the ‘no patency’ group had significant stenosis. Sensitivity, specificity, and negative and positive predictive values of PC examination for detecting small bowel stenosis were 93.8%, 96.6%, 99.6%, and 62.5%, respectively, and the only clinical factor related to false-positive cases was constipation (p < 0.05). CONCLUSION: We found a relatively low positive predictive value of PC examination and that constipation was related to false-positive results. To extend the implications of CE indications, clinical study focusing on these results is expected. SAGE Publications 2017-08-07 2017-08 /pmc/articles/PMC5557191/ /pubmed/28835773 http://dx.doi.org/10.1177/1756283X17722744 Text en © The Author(s), 2017 http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Research Sawada, Tsunaki Nakamura, Masanao Watanabe, Osamu Yamamura, Takeshi Ishikawa, Takuya Furukawa, Kazuhiro Funasaka, Kohei Ohno, Eizaburo Kawashima, Hiroki Miyahara, Ryoji Goto, Hidemi Hirooka, Yoshiki Clinical factors related to false-positive rates of patency capsule examination |
title | Clinical factors related to false-positive rates of patency capsule examination |
title_full | Clinical factors related to false-positive rates of patency capsule examination |
title_fullStr | Clinical factors related to false-positive rates of patency capsule examination |
title_full_unstemmed | Clinical factors related to false-positive rates of patency capsule examination |
title_short | Clinical factors related to false-positive rates of patency capsule examination |
title_sort | clinical factors related to false-positive rates of patency capsule examination |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5557191/ https://www.ncbi.nlm.nih.gov/pubmed/28835773 http://dx.doi.org/10.1177/1756283X17722744 |
work_keys_str_mv | AT sawadatsunaki clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination AT nakamuramasanao clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination AT watanabeosamu clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination AT yamamuratakeshi clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination AT ishikawatakuya clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination AT furukawakazuhiro clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination AT funasakakohei clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination AT ohnoeizaburo clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination AT kawashimahiroki clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination AT miyahararyoji clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination AT gotohidemi clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination AT hirookayoshiki clinicalfactorsrelatedtofalsepositiveratesofpatencycapsuleexamination |