Cargando…

Patterns of locoregional failure following post-operative intensity-modulated radiotherapy to oral cavity cancer: quantitative spatial and dosimetric analysis using a deformable image registration workflow

BACKGROUND: We sought to identify spatial/dosimetric patterns of failure for oral cavity cancer patients receiving post-operative IMRT (PO-IMRT). METHODS: Two hundred eighty-nine OCC patients receiving PO-IMRT were retrospectively reviewed from 2000 to 2012. Diagnostic CT documenting recurrence (rCT...

Descripción completa

Detalles Bibliográficos
Autores principales: Mohamed, Abdallah S. R., Wong, Andrew J., Fuller, Clifton D., Kamal, Mona, Gunn, Gary B., Phan, Jack, Morrison, William H., Beadle, Beth M., Skinner, Heath, Lai, Stephen Y., Quinlan-Davidson, Sean R., Belal, Abdelaziz M., El-Gowily, Ahmed G., Frank, Steven J., Rosenthal, David I., Garden, Adam S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5557312/
https://www.ncbi.nlm.nih.gov/pubmed/28806994
http://dx.doi.org/10.1186/s13014-017-0868-y
_version_ 1783257190187925504
author Mohamed, Abdallah S. R.
Wong, Andrew J.
Fuller, Clifton D.
Kamal, Mona
Gunn, Gary B.
Phan, Jack
Morrison, William H.
Beadle, Beth M.
Skinner, Heath
Lai, Stephen Y.
Quinlan-Davidson, Sean R.
Belal, Abdelaziz M.
El-Gowily, Ahmed G.
Frank, Steven J.
Rosenthal, David I.
Garden, Adam S.
author_facet Mohamed, Abdallah S. R.
Wong, Andrew J.
Fuller, Clifton D.
Kamal, Mona
Gunn, Gary B.
Phan, Jack
Morrison, William H.
Beadle, Beth M.
Skinner, Heath
Lai, Stephen Y.
Quinlan-Davidson, Sean R.
Belal, Abdelaziz M.
El-Gowily, Ahmed G.
Frank, Steven J.
Rosenthal, David I.
Garden, Adam S.
author_sort Mohamed, Abdallah S. R.
collection PubMed
description BACKGROUND: We sought to identify spatial/dosimetric patterns of failure for oral cavity cancer patients receiving post-operative IMRT (PO-IMRT). METHODS: Two hundred eighty-nine OCC patients receiving PO-IMRT were retrospectively reviewed from 2000 to 2012. Diagnostic CT documenting recurrence (rCT) was co-registered with planning CT (pCT) using a validated deformable image registration software. Manually segmented recurrent gross disease (rGTV) was deformed to co-registered pCTs. Mapped rGTVs were compared dosimetrically to planned dose and spatially to planning target volumes using centroid-based approaches. Failures types were classified using combined spatial/dosimetric criteria: A (central high-dose), B (peripheral high-dose), C (central intermediate/low-dose), D (peripheral intermediate/low-dose), and E (extraneous-dose). RESULTS: Fifty-four patients with recurrence were analyzed; 26 local recurrence, 19 regional recurrence, and 9 both local and regional recurrence. Median time to recurrence was 4 months (range 0–71). Median rGTVs volume was 3.7 cm(3) (IQR 1.4–10.6). For spatial and dosimetric analysis of the patterns of failure, 30 patients (55.5%) were classified as type A (central high-dose). Non-central high dose failures were distributed as follows: 2 (3.7%) type B, 10 (18.5%) type C, 1 (1.8%) type D, and 9 (16.7%) type E. Non-IMRT failure in the matching low-neck field was seen in two patients. No failures were noted at the IMRT-supraclavicular field match-line. CONCLUSIONS: Approximately half of patients with local/regional failure had non-central high dose recurrence. Peripheral high dose misses were uncommon reflecting adequate delineation and dose delivery. Future strategies are needed to reduce types C and E failures. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13014-017-0868-y) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-5557312
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-55573122017-08-16 Patterns of locoregional failure following post-operative intensity-modulated radiotherapy to oral cavity cancer: quantitative spatial and dosimetric analysis using a deformable image registration workflow Mohamed, Abdallah S. R. Wong, Andrew J. Fuller, Clifton D. Kamal, Mona Gunn, Gary B. Phan, Jack Morrison, William H. Beadle, Beth M. Skinner, Heath Lai, Stephen Y. Quinlan-Davidson, Sean R. Belal, Abdelaziz M. El-Gowily, Ahmed G. Frank, Steven J. Rosenthal, David I. Garden, Adam S. Radiat Oncol Research BACKGROUND: We sought to identify spatial/dosimetric patterns of failure for oral cavity cancer patients receiving post-operative IMRT (PO-IMRT). METHODS: Two hundred eighty-nine OCC patients receiving PO-IMRT were retrospectively reviewed from 2000 to 2012. Diagnostic CT documenting recurrence (rCT) was co-registered with planning CT (pCT) using a validated deformable image registration software. Manually segmented recurrent gross disease (rGTV) was deformed to co-registered pCTs. Mapped rGTVs were compared dosimetrically to planned dose and spatially to planning target volumes using centroid-based approaches. Failures types were classified using combined spatial/dosimetric criteria: A (central high-dose), B (peripheral high-dose), C (central intermediate/low-dose), D (peripheral intermediate/low-dose), and E (extraneous-dose). RESULTS: Fifty-four patients with recurrence were analyzed; 26 local recurrence, 19 regional recurrence, and 9 both local and regional recurrence. Median time to recurrence was 4 months (range 0–71). Median rGTVs volume was 3.7 cm(3) (IQR 1.4–10.6). For spatial and dosimetric analysis of the patterns of failure, 30 patients (55.5%) were classified as type A (central high-dose). Non-central high dose failures were distributed as follows: 2 (3.7%) type B, 10 (18.5%) type C, 1 (1.8%) type D, and 9 (16.7%) type E. Non-IMRT failure in the matching low-neck field was seen in two patients. No failures were noted at the IMRT-supraclavicular field match-line. CONCLUSIONS: Approximately half of patients with local/regional failure had non-central high dose recurrence. Peripheral high dose misses were uncommon reflecting adequate delineation and dose delivery. Future strategies are needed to reduce types C and E failures. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13014-017-0868-y) contains supplementary material, which is available to authorized users. BioMed Central 2017-08-15 /pmc/articles/PMC5557312/ /pubmed/28806994 http://dx.doi.org/10.1186/s13014-017-0868-y Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Mohamed, Abdallah S. R.
Wong, Andrew J.
Fuller, Clifton D.
Kamal, Mona
Gunn, Gary B.
Phan, Jack
Morrison, William H.
Beadle, Beth M.
Skinner, Heath
Lai, Stephen Y.
Quinlan-Davidson, Sean R.
Belal, Abdelaziz M.
El-Gowily, Ahmed G.
Frank, Steven J.
Rosenthal, David I.
Garden, Adam S.
Patterns of locoregional failure following post-operative intensity-modulated radiotherapy to oral cavity cancer: quantitative spatial and dosimetric analysis using a deformable image registration workflow
title Patterns of locoregional failure following post-operative intensity-modulated radiotherapy to oral cavity cancer: quantitative spatial and dosimetric analysis using a deformable image registration workflow
title_full Patterns of locoregional failure following post-operative intensity-modulated radiotherapy to oral cavity cancer: quantitative spatial and dosimetric analysis using a deformable image registration workflow
title_fullStr Patterns of locoregional failure following post-operative intensity-modulated radiotherapy to oral cavity cancer: quantitative spatial and dosimetric analysis using a deformable image registration workflow
title_full_unstemmed Patterns of locoregional failure following post-operative intensity-modulated radiotherapy to oral cavity cancer: quantitative spatial and dosimetric analysis using a deformable image registration workflow
title_short Patterns of locoregional failure following post-operative intensity-modulated radiotherapy to oral cavity cancer: quantitative spatial and dosimetric analysis using a deformable image registration workflow
title_sort patterns of locoregional failure following post-operative intensity-modulated radiotherapy to oral cavity cancer: quantitative spatial and dosimetric analysis using a deformable image registration workflow
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5557312/
https://www.ncbi.nlm.nih.gov/pubmed/28806994
http://dx.doi.org/10.1186/s13014-017-0868-y
work_keys_str_mv AT mohamedabdallahsr patternsoflocoregionalfailurefollowingpostoperativeintensitymodulatedradiotherapytooralcavitycancerquantitativespatialanddosimetricanalysisusingadeformableimageregistrationworkflow
AT wongandrewj patternsoflocoregionalfailurefollowingpostoperativeintensitymodulatedradiotherapytooralcavitycancerquantitativespatialanddosimetricanalysisusingadeformableimageregistrationworkflow
AT fullercliftond patternsoflocoregionalfailurefollowingpostoperativeintensitymodulatedradiotherapytooralcavitycancerquantitativespatialanddosimetricanalysisusingadeformableimageregistrationworkflow
AT kamalmona patternsoflocoregionalfailurefollowingpostoperativeintensitymodulatedradiotherapytooralcavitycancerquantitativespatialanddosimetricanalysisusingadeformableimageregistrationworkflow
AT gunngaryb patternsoflocoregionalfailurefollowingpostoperativeintensitymodulatedradiotherapytooralcavitycancerquantitativespatialanddosimetricanalysisusingadeformableimageregistrationworkflow
AT phanjack patternsoflocoregionalfailurefollowingpostoperativeintensitymodulatedradiotherapytooralcavitycancerquantitativespatialanddosimetricanalysisusingadeformableimageregistrationworkflow
AT morrisonwilliamh patternsoflocoregionalfailurefollowingpostoperativeintensitymodulatedradiotherapytooralcavitycancerquantitativespatialanddosimetricanalysisusingadeformableimageregistrationworkflow
AT beadlebethm patternsoflocoregionalfailurefollowingpostoperativeintensitymodulatedradiotherapytooralcavitycancerquantitativespatialanddosimetricanalysisusingadeformableimageregistrationworkflow
AT skinnerheath patternsoflocoregionalfailurefollowingpostoperativeintensitymodulatedradiotherapytooralcavitycancerquantitativespatialanddosimetricanalysisusingadeformableimageregistrationworkflow
AT laistepheny patternsoflocoregionalfailurefollowingpostoperativeintensitymodulatedradiotherapytooralcavitycancerquantitativespatialanddosimetricanalysisusingadeformableimageregistrationworkflow
AT quinlandavidsonseanr patternsoflocoregionalfailurefollowingpostoperativeintensitymodulatedradiotherapytooralcavitycancerquantitativespatialanddosimetricanalysisusingadeformableimageregistrationworkflow
AT belalabdelazizm patternsoflocoregionalfailurefollowingpostoperativeintensitymodulatedradiotherapytooralcavitycancerquantitativespatialanddosimetricanalysisusingadeformableimageregistrationworkflow
AT elgowilyahmedg patternsoflocoregionalfailurefollowingpostoperativeintensitymodulatedradiotherapytooralcavitycancerquantitativespatialanddosimetricanalysisusingadeformableimageregistrationworkflow
AT frankstevenj patternsoflocoregionalfailurefollowingpostoperativeintensitymodulatedradiotherapytooralcavitycancerquantitativespatialanddosimetricanalysisusingadeformableimageregistrationworkflow
AT rosenthaldavidi patternsoflocoregionalfailurefollowingpostoperativeintensitymodulatedradiotherapytooralcavitycancerquantitativespatialanddosimetricanalysisusingadeformableimageregistrationworkflow
AT gardenadams patternsoflocoregionalfailurefollowingpostoperativeintensitymodulatedradiotherapytooralcavitycancerquantitativespatialanddosimetricanalysisusingadeformableimageregistrationworkflow