Cargando…

Comparison of different laboratory tests in the evaluation of hemorrhagic risk of patients using rivaroxaban in the critical care setting: diagnostic accuracy study

BACKGROUND: Rivaroxaban is a direct oral anticoagulant designed to dispense with the necessity of laboratory monitoring. However, monitoring rivaroxaban levels is necessary in certain clinical conditions, especially in the critical care setting. METHODS: This is a diagnostic accuracy study evaluatin...

Descripción completa

Detalles Bibliográficos
Autores principales: Colombini, Marjorie Paris, Derogis, Priscilla Bento Matos Cruz, de Aranda, Valdir Fernandes, de Campos Guerra, João Carlos, Hamerschlak, Nelson, Mangueira, Cristóvão Luis Pitangueiras
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5557535/
https://www.ncbi.nlm.nih.gov/pubmed/28814943
http://dx.doi.org/10.1186/s12959-017-0140-6
_version_ 1783257225114943488
author Colombini, Marjorie Paris
Derogis, Priscilla Bento Matos Cruz
de Aranda, Valdir Fernandes
de Campos Guerra, João Carlos
Hamerschlak, Nelson
Mangueira, Cristóvão Luis Pitangueiras
author_facet Colombini, Marjorie Paris
Derogis, Priscilla Bento Matos Cruz
de Aranda, Valdir Fernandes
de Campos Guerra, João Carlos
Hamerschlak, Nelson
Mangueira, Cristóvão Luis Pitangueiras
author_sort Colombini, Marjorie Paris
collection PubMed
description BACKGROUND: Rivaroxaban is a direct oral anticoagulant designed to dispense with the necessity of laboratory monitoring. However, monitoring rivaroxaban levels is necessary in certain clinical conditions, especially in the critical care setting. METHODS: This is a diagnostic accuracy study evaluating sensitivity and specificity of prothrombin time (PT), activated partial thromboplastin time (aPTT), and Dilute Russell viper venom time (dRVVT), to evaluate the hemorrhagic risk in patients taking rivaroxaban. The study used a convenience sample of 40 clinically stable patients using rivaroxaban to treat deep vein thrombosis or atrial fibrillation admitted in a private hospital in Brazil, compared to a group of 60 healthy controls. The samples from patients were collected two hours after the use of the medication (peak) and two hours before the next dose (trough). RESULTS: The correlation with the plasmatic concentration measured by anti-FXa assay was higher for PT and dRVVTS. The PT and aPTT tests presented higher specificity, while dRVVT was 100% sensible. CONCLUSIONS: There was a strong correlation between the tests and the plasma concentration of the drug. Additionally, our results demonstrated the potential use of dRVVT as a screening test in the emergency room and the need of a second test to improve specificity.
format Online
Article
Text
id pubmed-5557535
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-55575352017-08-16 Comparison of different laboratory tests in the evaluation of hemorrhagic risk of patients using rivaroxaban in the critical care setting: diagnostic accuracy study Colombini, Marjorie Paris Derogis, Priscilla Bento Matos Cruz de Aranda, Valdir Fernandes de Campos Guerra, João Carlos Hamerschlak, Nelson Mangueira, Cristóvão Luis Pitangueiras Thromb J Research BACKGROUND: Rivaroxaban is a direct oral anticoagulant designed to dispense with the necessity of laboratory monitoring. However, monitoring rivaroxaban levels is necessary in certain clinical conditions, especially in the critical care setting. METHODS: This is a diagnostic accuracy study evaluating sensitivity and specificity of prothrombin time (PT), activated partial thromboplastin time (aPTT), and Dilute Russell viper venom time (dRVVT), to evaluate the hemorrhagic risk in patients taking rivaroxaban. The study used a convenience sample of 40 clinically stable patients using rivaroxaban to treat deep vein thrombosis or atrial fibrillation admitted in a private hospital in Brazil, compared to a group of 60 healthy controls. The samples from patients were collected two hours after the use of the medication (peak) and two hours before the next dose (trough). RESULTS: The correlation with the plasmatic concentration measured by anti-FXa assay was higher for PT and dRVVTS. The PT and aPTT tests presented higher specificity, while dRVVT was 100% sensible. CONCLUSIONS: There was a strong correlation between the tests and the plasma concentration of the drug. Additionally, our results demonstrated the potential use of dRVVT as a screening test in the emergency room and the need of a second test to improve specificity. BioMed Central 2017-08-15 /pmc/articles/PMC5557535/ /pubmed/28814943 http://dx.doi.org/10.1186/s12959-017-0140-6 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Colombini, Marjorie Paris
Derogis, Priscilla Bento Matos Cruz
de Aranda, Valdir Fernandes
de Campos Guerra, João Carlos
Hamerschlak, Nelson
Mangueira, Cristóvão Luis Pitangueiras
Comparison of different laboratory tests in the evaluation of hemorrhagic risk of patients using rivaroxaban in the critical care setting: diagnostic accuracy study
title Comparison of different laboratory tests in the evaluation of hemorrhagic risk of patients using rivaroxaban in the critical care setting: diagnostic accuracy study
title_full Comparison of different laboratory tests in the evaluation of hemorrhagic risk of patients using rivaroxaban in the critical care setting: diagnostic accuracy study
title_fullStr Comparison of different laboratory tests in the evaluation of hemorrhagic risk of patients using rivaroxaban in the critical care setting: diagnostic accuracy study
title_full_unstemmed Comparison of different laboratory tests in the evaluation of hemorrhagic risk of patients using rivaroxaban in the critical care setting: diagnostic accuracy study
title_short Comparison of different laboratory tests in the evaluation of hemorrhagic risk of patients using rivaroxaban in the critical care setting: diagnostic accuracy study
title_sort comparison of different laboratory tests in the evaluation of hemorrhagic risk of patients using rivaroxaban in the critical care setting: diagnostic accuracy study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5557535/
https://www.ncbi.nlm.nih.gov/pubmed/28814943
http://dx.doi.org/10.1186/s12959-017-0140-6
work_keys_str_mv AT colombinimarjorieparis comparisonofdifferentlaboratorytestsintheevaluationofhemorrhagicriskofpatientsusingrivaroxabaninthecriticalcaresettingdiagnosticaccuracystudy
AT derogispriscillabentomatoscruz comparisonofdifferentlaboratorytestsintheevaluationofhemorrhagicriskofpatientsusingrivaroxabaninthecriticalcaresettingdiagnosticaccuracystudy
AT dearandavaldirfernandes comparisonofdifferentlaboratorytestsintheevaluationofhemorrhagicriskofpatientsusingrivaroxabaninthecriticalcaresettingdiagnosticaccuracystudy
AT decamposguerrajoaocarlos comparisonofdifferentlaboratorytestsintheevaluationofhemorrhagicriskofpatientsusingrivaroxabaninthecriticalcaresettingdiagnosticaccuracystudy
AT hamerschlaknelson comparisonofdifferentlaboratorytestsintheevaluationofhemorrhagicriskofpatientsusingrivaroxabaninthecriticalcaresettingdiagnosticaccuracystudy
AT mangueiracristovaoluispitangueiras comparisonofdifferentlaboratorytestsintheevaluationofhemorrhagicriskofpatientsusingrivaroxabaninthecriticalcaresettingdiagnosticaccuracystudy