Cargando…
DVH- and NTCP-based dosimetric comparison of different longitudinal margins for VMAT-IMRT of esophageal cancer
PURPOSE: To cover the microscopic tumor spread in squamous cell carcinoma of the esophagus (SCC), longitudinal margins of 3–4 cm are used for radiotherapy (RT) protocols. However, smaller margins of 2–3 cm might be reasonable when advanced diagnostic imaging is integrated into target volume delineat...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5557554/ https://www.ncbi.nlm.nih.gov/pubmed/28806990 http://dx.doi.org/10.1186/s13014-017-0871-3 |
Sumario: | PURPOSE: To cover the microscopic tumor spread in squamous cell carcinoma of the esophagus (SCC), longitudinal margins of 3–4 cm are used for radiotherapy (RT) protocols. However, smaller margins of 2–3 cm might be reasonable when advanced diagnostic imaging is integrated into target volume delineation. Purpose of this study was to compare the dose distribution and deposition to the organs at risk (OAR) for different longitudinal margins using a DVH- and NTCP-based approach. METHODS: Ten patients with SCC of the middle or lower third were retrospectively selected. Three planning target volumes (PTV) with longitudinal margins of 4 cm, 3 cm and 2 cm and an axial margin of 1.5 cm to the gross target volume (GTV) were defined for each patient. For each PTV two treatment plans with total doses of 41.4 Gy (neoadjuvant treatment) and 50.4 Gy (definite treatment) were calculated. Dose to the lungs, heart, myelon and liver were then evaluated and compared between different PTVs. RESULTS: When using a longitudinal margin of 3 cm instead of 4 cm, all dose parameters (Dmin, Dmean, Dmedian and V5-V35), except Dmax could be significantly reduced for the lungs. Regarding the heart, a significant reduction was seen for Dmean and V5, but not for Dmin, Dmax, Dmedian and V10-V35. When comparing a longitudinal margin of 4 cm to a longitudinal margin of 2 cm, a significant difference was calculated for Dmin, Dmean, Dmedian and V5-V35 of the lungs and for Dmax, Dmean and V5-V35 of the heart. Nevertheless, no difference was seen for median heart dose. An additional dose reduction for V10 of the heart was achieved for definite treatment plans when using a longitudinal margin of 3 cm. The NTCP-based risk of pneumonitis was significantly reduced by a margin reduction to 2 cm for neoadjuvant and definite treatment plans. CONCLUSION: Reduction of longitudinal margins from 4 cm to 3 cm can significantly reduce the dose to lungs and Dmean of the heart. Despite clinical benefit and oncologic outcome remain unclear, reduction of the longitudinal margins might provide the opportunity to reduce side effects of chemoradiation (CRT) for SCC in upcoming studies. |
---|