Cargando…

Repeatability and Reproducibility of Retinal Neuronal and Axonal Measures on Spectral-Domain Optical Coherence Tomography in Patients with Cognitive Impairment

BACKGROUND: With increasing interest in determining if measurement of retinal neuronal structure with spectral-domain optical coherence tomography (SD-OCT) is useful in accessing neurodegenerative process in cognitive decline and development of dementia, it is important to evaluate whether the SD-OC...

Descripción completa

Detalles Bibliográficos
Autores principales: Loh, Edwin Hong-Teck, Ong, Yi-Ting, Venketasubramanian, Narayanaswamy, Hilal, Saima, Thet, Naing, Wong, Tien Yin, Chen, Christopher P. L., Cheung, Carol Yim-lui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5559462/
https://www.ncbi.nlm.nih.gov/pubmed/28861029
http://dx.doi.org/10.3389/fneur.2017.00359
_version_ 1783257519485878272
author Loh, Edwin Hong-Teck
Ong, Yi-Ting
Venketasubramanian, Narayanaswamy
Hilal, Saima
Thet, Naing
Wong, Tien Yin
Chen, Christopher P. L.
Cheung, Carol Yim-lui
author_facet Loh, Edwin Hong-Teck
Ong, Yi-Ting
Venketasubramanian, Narayanaswamy
Hilal, Saima
Thet, Naing
Wong, Tien Yin
Chen, Christopher P. L.
Cheung, Carol Yim-lui
author_sort Loh, Edwin Hong-Teck
collection PubMed
description BACKGROUND: With increasing interest in determining if measurement of retinal neuronal structure with spectral-domain optical coherence tomography (SD-OCT) is useful in accessing neurodegenerative process in cognitive decline and development of dementia, it is important to evaluate whether the SD-OCT measurements are repeatable and reproducible in these patients. METHODS: This is a retrospective cohort study. Patients with Alzheimer’s disease (AD) or mild cognitive impairment (MCI) with no change in global clinical dementia rating (CDR) score at 1-year follow-up were eligible to be included. Ganglion cell-inner plexiform layer (GC-IPL) and retinal nerve fiber layer (RNFL) parameters were measured with SD-OCT at baseline, 6-month, and 1-year follow-up visits. At baseline, SD-OCT scans were repeated to access intra-visit repeatability of the SD-OCT measurement. SD-OCT measurement over three visits was used to access inter-visit reproducibility. We calculated intraclass correlation coefficients (ICC) and coefficients of variation (CoVs). RESULTS: We included 32 patients with stable AD and 29 patients with stable MCI in the final analysis. For GC-IPL measures, the average intra-visit ICC was 0.969 (range: 0.948–0.985), and CoV was 1.81% (range: 1.14–2.40); while the average inter-visit ICC was 0.968 (0.941–0.985), and CoV was 1.91% (range: 1.24–2.32). The average ICC and CoV of intra-visit RNFL measured were 0.965 (range: 0.937–0.986) and 2.32% (range: 1.34–2.90%), respectively. The average ICC and CoV of inter-visit RNFL measures were 0.927 (range: 0.845–0.961) and 3.83% (range: 2.71–5.25%), respectively. CONCLUSION: Both GC-IPL and RNFL measurements had good intra-visit repeatability and inter-visit reproducibility over 1 year in elderly patients with no decline in cognitive function, suggesting that SD-OCT is a reliable tool to assess neurodegenerative process over time.
format Online
Article
Text
id pubmed-5559462
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-55594622017-08-31 Repeatability and Reproducibility of Retinal Neuronal and Axonal Measures on Spectral-Domain Optical Coherence Tomography in Patients with Cognitive Impairment Loh, Edwin Hong-Teck Ong, Yi-Ting Venketasubramanian, Narayanaswamy Hilal, Saima Thet, Naing Wong, Tien Yin Chen, Christopher P. L. Cheung, Carol Yim-lui Front Neurol Neuroscience BACKGROUND: With increasing interest in determining if measurement of retinal neuronal structure with spectral-domain optical coherence tomography (SD-OCT) is useful in accessing neurodegenerative process in cognitive decline and development of dementia, it is important to evaluate whether the SD-OCT measurements are repeatable and reproducible in these patients. METHODS: This is a retrospective cohort study. Patients with Alzheimer’s disease (AD) or mild cognitive impairment (MCI) with no change in global clinical dementia rating (CDR) score at 1-year follow-up were eligible to be included. Ganglion cell-inner plexiform layer (GC-IPL) and retinal nerve fiber layer (RNFL) parameters were measured with SD-OCT at baseline, 6-month, and 1-year follow-up visits. At baseline, SD-OCT scans were repeated to access intra-visit repeatability of the SD-OCT measurement. SD-OCT measurement over three visits was used to access inter-visit reproducibility. We calculated intraclass correlation coefficients (ICC) and coefficients of variation (CoVs). RESULTS: We included 32 patients with stable AD and 29 patients with stable MCI in the final analysis. For GC-IPL measures, the average intra-visit ICC was 0.969 (range: 0.948–0.985), and CoV was 1.81% (range: 1.14–2.40); while the average inter-visit ICC was 0.968 (0.941–0.985), and CoV was 1.91% (range: 1.24–2.32). The average ICC and CoV of intra-visit RNFL measured were 0.965 (range: 0.937–0.986) and 2.32% (range: 1.34–2.90%), respectively. The average ICC and CoV of inter-visit RNFL measures were 0.927 (range: 0.845–0.961) and 3.83% (range: 2.71–5.25%), respectively. CONCLUSION: Both GC-IPL and RNFL measurements had good intra-visit repeatability and inter-visit reproducibility over 1 year in elderly patients with no decline in cognitive function, suggesting that SD-OCT is a reliable tool to assess neurodegenerative process over time. Frontiers Media S.A. 2017-08-15 /pmc/articles/PMC5559462/ /pubmed/28861029 http://dx.doi.org/10.3389/fneur.2017.00359 Text en Copyright © 2017 Loh, Ong, Venketasubramanian, Hilal, Thet, Wong, Chen and Cheung. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Loh, Edwin Hong-Teck
Ong, Yi-Ting
Venketasubramanian, Narayanaswamy
Hilal, Saima
Thet, Naing
Wong, Tien Yin
Chen, Christopher P. L.
Cheung, Carol Yim-lui
Repeatability and Reproducibility of Retinal Neuronal and Axonal Measures on Spectral-Domain Optical Coherence Tomography in Patients with Cognitive Impairment
title Repeatability and Reproducibility of Retinal Neuronal and Axonal Measures on Spectral-Domain Optical Coherence Tomography in Patients with Cognitive Impairment
title_full Repeatability and Reproducibility of Retinal Neuronal and Axonal Measures on Spectral-Domain Optical Coherence Tomography in Patients with Cognitive Impairment
title_fullStr Repeatability and Reproducibility of Retinal Neuronal and Axonal Measures on Spectral-Domain Optical Coherence Tomography in Patients with Cognitive Impairment
title_full_unstemmed Repeatability and Reproducibility of Retinal Neuronal and Axonal Measures on Spectral-Domain Optical Coherence Tomography in Patients with Cognitive Impairment
title_short Repeatability and Reproducibility of Retinal Neuronal and Axonal Measures on Spectral-Domain Optical Coherence Tomography in Patients with Cognitive Impairment
title_sort repeatability and reproducibility of retinal neuronal and axonal measures on spectral-domain optical coherence tomography in patients with cognitive impairment
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5559462/
https://www.ncbi.nlm.nih.gov/pubmed/28861029
http://dx.doi.org/10.3389/fneur.2017.00359
work_keys_str_mv AT lohedwinhongteck repeatabilityandreproducibilityofretinalneuronalandaxonalmeasuresonspectraldomainopticalcoherencetomographyinpatientswithcognitiveimpairment
AT ongyiting repeatabilityandreproducibilityofretinalneuronalandaxonalmeasuresonspectraldomainopticalcoherencetomographyinpatientswithcognitiveimpairment
AT venketasubramaniannarayanaswamy repeatabilityandreproducibilityofretinalneuronalandaxonalmeasuresonspectraldomainopticalcoherencetomographyinpatientswithcognitiveimpairment
AT hilalsaima repeatabilityandreproducibilityofretinalneuronalandaxonalmeasuresonspectraldomainopticalcoherencetomographyinpatientswithcognitiveimpairment
AT thetnaing repeatabilityandreproducibilityofretinalneuronalandaxonalmeasuresonspectraldomainopticalcoherencetomographyinpatientswithcognitiveimpairment
AT wongtienyin repeatabilityandreproducibilityofretinalneuronalandaxonalmeasuresonspectraldomainopticalcoherencetomographyinpatientswithcognitiveimpairment
AT chenchristopherpl repeatabilityandreproducibilityofretinalneuronalandaxonalmeasuresonspectraldomainopticalcoherencetomographyinpatientswithcognitiveimpairment
AT cheungcarolyimlui repeatabilityandreproducibilityofretinalneuronalandaxonalmeasuresonspectraldomainopticalcoherencetomographyinpatientswithcognitiveimpairment