Cargando…
Urine flow rate monitoring in hypovolemic multiple trauma patients
BACKGROUND: The urine output is an important clinical parameter of renal function and blood volume status, especially in critically ill multiple trauma patients. In the present study, the minute-to-minute urine flow rate and its variability were analyzed in hypotensive multiple trauma patients durin...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5563012/ https://www.ncbi.nlm.nih.gov/pubmed/28828035 http://dx.doi.org/10.1186/s13017-017-0152-3 |
Sumario: | BACKGROUND: The urine output is an important clinical parameter of renal function and blood volume status, especially in critically ill multiple trauma patients. In the present study, the minute-to-minute urine flow rate and its variability were analyzed in hypotensive multiple trauma patients during the first 6 h of their ICU (intensive care unit) stay. These parameters have not been previously reported. METHODS: The study was retrospective and observational. Demographic and clinical data were extracted from the computerized Register Information Systems. A total of 59 patients were included in the study. The patients were divided into two study groups. Group 1 consisted of 29 multiple trauma patients whose systolic blood pressure was greater than 90 mmHg on admission to the ICU and who were consequently deemed to be hemodynamically compromised. Group 2 consisted of 30 patients whose systolic blood pressure was less than 90 mmHg on admission to the ICU and who were therefore regarded as hemodynamically uncompromised. RESULTS: The urine output and urine flow rate variability during the first 6 h of the patients’ ICU stay was significantly lower in group 2 than in group 1 (p < 0.001 and 0.006 respectively). Statistical analysis by the Pearson method demonstrated a strong direct correlation between decreased urine flow rate variability and decreased urine output per hour (R = 0.17; P = 0.009), decreased mean arterial blood pressure (R = 0.24; p = 0.001), and increased heart rate (R = 0.205; p = 0.001). CONCLUSION: These findings suggest that minute-to-minute urine flow rate variability is a reliable incipient marker of hypovolemia and that it should therefore take its place among the parameters used to monitor the hemodynamic status of critically ill multiple trauma patients. |
---|