Cargando…

Intraocular Pressure and Retinal Nerve Fibre Layer Thickness Changes After Carotid Artery Stenting

OBJECTIVES: The aim of this study was to evaluate intraocular pressure (IOP) and retinal nerve fiber layer (RNFL) changes in patients with carotid artery stenosis (CAS) after carotid artery stenting. MATERIALS AND METHODS: This study was conducted as a cross-sectional, non-randomised clinical case s...

Descripción completa

Detalles Bibliográficos
Autores principales: Biberoğlu, Esra, Eraslan, Muhsin, Baltacıoğlu, Feyyaz, Midi, İpek
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Galenos Publishing 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5563546/
https://www.ncbi.nlm.nih.gov/pubmed/28845322
http://dx.doi.org/10.4274/tjo.67809
_version_ 1783258147296641024
author Biberoğlu, Esra
Eraslan, Muhsin
Baltacıoğlu, Feyyaz
Midi, İpek
author_facet Biberoğlu, Esra
Eraslan, Muhsin
Baltacıoğlu, Feyyaz
Midi, İpek
author_sort Biberoğlu, Esra
collection PubMed
description OBJECTIVES: The aim of this study was to evaluate intraocular pressure (IOP) and retinal nerve fiber layer (RNFL) changes in patients with carotid artery stenosis (CAS) after carotid artery stenting. MATERIALS AND METHODS: This study was conducted as a cross-sectional, non-randomised clinical case series. Fifteen male patients (mean age: 63.6±9.1) with CAS and more than 70% carotid artery narrowing were included. All of the patients were followed in the department of neurology and were operated in the interventional radiology division. Eighteen healthy male subjects (mean age: 63.7±5.3) were included in the control group. All of the healthy subjects had a detailed ophthalmological examination and subjects with any chronic eye disease were excluded from the study. All of the participants had a detailed ophthalmological examination including tonometry using Goldmann applanation tonometry and RNFL analysis using optical coherence tomography (RTVue-100 5.1). RESULTS: There were no ocular ischemic symptoms in any of the participants. The mean IOP value was 15.1±2.1 mmHg in the control group and 16.6±2.4 mmHg before stent implantation, 16.4±2.2 mmHg at 1 week after implantation, 16.6±2.5 mmHg at 1 month after implantation, and 16.7±2.9 mmHg at 3 months after implantation in the CAS group. Mean RNFL thickness was 105±6 µm in the control group; in the CAS group, mean RNFL thickness values were 98±27 µm before stent implantation and 103±11 µm, 101±10 µm, and 101±11 µm at 1 week, 1 month, and 3 months after stenting. There were no significant differences between the CAS group and control group regarding IOP and RNFL thickness values (p>0.05). IOP and RNFL thickness also did not show any statistically significant changes from preoperative measurements in 3 months postoperative follow-up in the CAS group (p>0.05). CONCLUSION: IOP and RNFL thickness remained unchanged after carotid stent implantation in carotid artery stenosis patients with no signs of ocular ischemic syndrome.
format Online
Article
Text
id pubmed-5563546
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Galenos Publishing
record_format MEDLINE/PubMed
spelling pubmed-55635462017-08-25 Intraocular Pressure and Retinal Nerve Fibre Layer Thickness Changes After Carotid Artery Stenting Biberoğlu, Esra Eraslan, Muhsin Baltacıoğlu, Feyyaz Midi, İpek Turk J Ophthalmol Original Article OBJECTIVES: The aim of this study was to evaluate intraocular pressure (IOP) and retinal nerve fiber layer (RNFL) changes in patients with carotid artery stenosis (CAS) after carotid artery stenting. MATERIALS AND METHODS: This study was conducted as a cross-sectional, non-randomised clinical case series. Fifteen male patients (mean age: 63.6±9.1) with CAS and more than 70% carotid artery narrowing were included. All of the patients were followed in the department of neurology and were operated in the interventional radiology division. Eighteen healthy male subjects (mean age: 63.7±5.3) were included in the control group. All of the healthy subjects had a detailed ophthalmological examination and subjects with any chronic eye disease were excluded from the study. All of the participants had a detailed ophthalmological examination including tonometry using Goldmann applanation tonometry and RNFL analysis using optical coherence tomography (RTVue-100 5.1). RESULTS: There were no ocular ischemic symptoms in any of the participants. The mean IOP value was 15.1±2.1 mmHg in the control group and 16.6±2.4 mmHg before stent implantation, 16.4±2.2 mmHg at 1 week after implantation, 16.6±2.5 mmHg at 1 month after implantation, and 16.7±2.9 mmHg at 3 months after implantation in the CAS group. Mean RNFL thickness was 105±6 µm in the control group; in the CAS group, mean RNFL thickness values were 98±27 µm before stent implantation and 103±11 µm, 101±10 µm, and 101±11 µm at 1 week, 1 month, and 3 months after stenting. There were no significant differences between the CAS group and control group regarding IOP and RNFL thickness values (p>0.05). IOP and RNFL thickness also did not show any statistically significant changes from preoperative measurements in 3 months postoperative follow-up in the CAS group (p>0.05). CONCLUSION: IOP and RNFL thickness remained unchanged after carotid stent implantation in carotid artery stenosis patients with no signs of ocular ischemic syndrome. Galenos Publishing 2017-08 2017-08-15 /pmc/articles/PMC5563546/ /pubmed/28845322 http://dx.doi.org/10.4274/tjo.67809 Text en ©Copyright 2017 by Turkish Ophthalmological Association Turkish Journal of Ophthalmology, published by Galenos Publishing House. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Biberoğlu, Esra
Eraslan, Muhsin
Baltacıoğlu, Feyyaz
Midi, İpek
Intraocular Pressure and Retinal Nerve Fibre Layer Thickness Changes After Carotid Artery Stenting
title Intraocular Pressure and Retinal Nerve Fibre Layer Thickness Changes After Carotid Artery Stenting
title_full Intraocular Pressure and Retinal Nerve Fibre Layer Thickness Changes After Carotid Artery Stenting
title_fullStr Intraocular Pressure and Retinal Nerve Fibre Layer Thickness Changes After Carotid Artery Stenting
title_full_unstemmed Intraocular Pressure and Retinal Nerve Fibre Layer Thickness Changes After Carotid Artery Stenting
title_short Intraocular Pressure and Retinal Nerve Fibre Layer Thickness Changes After Carotid Artery Stenting
title_sort intraocular pressure and retinal nerve fibre layer thickness changes after carotid artery stenting
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5563546/
https://www.ncbi.nlm.nih.gov/pubmed/28845322
http://dx.doi.org/10.4274/tjo.67809
work_keys_str_mv AT biberogluesra intraocularpressureandretinalnervefibrelayerthicknesschangesaftercarotidarterystenting
AT eraslanmuhsin intraocularpressureandretinalnervefibrelayerthicknesschangesaftercarotidarterystenting
AT baltacıoglufeyyaz intraocularpressureandretinalnervefibrelayerthicknesschangesaftercarotidarterystenting
AT midiipek intraocularpressureandretinalnervefibrelayerthicknesschangesaftercarotidarterystenting