Cargando…

Biodegradation of Biocomposite Suture Anchor Implants 2,2 years after Rotator Cuff Repair

OBJECTIVES: Arthroscopic rotator cuff repair is one of the most frequently performed operations in orthopaedic surgery. Resorbable PLLA or PGA implants have been reported to be associated with osteolysis. Biocomposite implants, composed of PLLA and/or PGA and ceramics, have gained popularity due to...

Descripción completa

Detalles Bibliográficos
Autores principales: Sgroi, Mirco, Friesz, Theresa, Reichel, Heiko, Kappe, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5564958/
http://dx.doi.org/10.1177/2325967117S00368
_version_ 1783258337482113024
author Sgroi, Mirco
Friesz, Theresa
Reichel, Heiko
Kappe, Thomas
author_facet Sgroi, Mirco
Friesz, Theresa
Reichel, Heiko
Kappe, Thomas
author_sort Sgroi, Mirco
collection PubMed
description OBJECTIVES: Arthroscopic rotator cuff repair is one of the most frequently performed operations in orthopaedic surgery. Resorbable PLLA or PGA implants have been reported to be associated with osteolysis. Biocomposite implants, composed of PLLA and/or PGA and ceramics, have gained popularity due to their biocompatibility and lack of osteolysis. The aim of the present study was to investigate the biodegradation progression of biocomposites suture anchor implants 2 years after rotator cuff repair. METHODS: Twenty-five consecutive patients (84 implants) with arthroscopically repaired rotator cuff tears using screw-in biocomposite implants with a 5,5 mm diameter and a minimum of 2 years (range, 16,3 to 32,0 months) follow-up were included into the present study. To analyse the biodegradation process of the suture anchors, an MRI of the operated shoulder was performed. The peri-implant fluid, the degradation of the suture anchors and the widening of the bone beds were assessed. RESULTS: In the present study, the structure of the suture anchor implants was clearly visible in 23.8%, visible in 42.9%, partially visible in 23.8%, and not visible in 9.5%. No peri-implant fluid was observed in 26,2%. Slight peri-implant fluid was seen in 34,5%, a continuous fringe of fluid at least 1 mm thick in 23,8% and more than 1mm thick in 13,1%. The mean width of the bone beds was 4,38 ± 1,28 mm (apex), 5,41± 1,12 mm (middle) and 5,88 ± 1,39 mm (basis), indicating a widening of 0.33 mm of the basis. The mean length of the bone beds was 19,09 ± 2,38 mm. No significant difference was found between the lateral and medial row or between knotted and knotless implants. No case of gross osteolysis was observed. CONCLUSION: The results of the present study show that biocomposite suture anchors are frequently still visible on MRI 2 years after a rotator cuff reconstruction. No gross osteolysis was observed in the present study, indicating good biocompatibility of the implants.
format Online
Article
Text
id pubmed-5564958
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-55649582017-08-24 Biodegradation of Biocomposite Suture Anchor Implants 2,2 years after Rotator Cuff Repair Sgroi, Mirco Friesz, Theresa Reichel, Heiko Kappe, Thomas Orthop J Sports Med Article OBJECTIVES: Arthroscopic rotator cuff repair is one of the most frequently performed operations in orthopaedic surgery. Resorbable PLLA or PGA implants have been reported to be associated with osteolysis. Biocomposite implants, composed of PLLA and/or PGA and ceramics, have gained popularity due to their biocompatibility and lack of osteolysis. The aim of the present study was to investigate the biodegradation progression of biocomposites suture anchor implants 2 years after rotator cuff repair. METHODS: Twenty-five consecutive patients (84 implants) with arthroscopically repaired rotator cuff tears using screw-in biocomposite implants with a 5,5 mm diameter and a minimum of 2 years (range, 16,3 to 32,0 months) follow-up were included into the present study. To analyse the biodegradation process of the suture anchors, an MRI of the operated shoulder was performed. The peri-implant fluid, the degradation of the suture anchors and the widening of the bone beds were assessed. RESULTS: In the present study, the structure of the suture anchor implants was clearly visible in 23.8%, visible in 42.9%, partially visible in 23.8%, and not visible in 9.5%. No peri-implant fluid was observed in 26,2%. Slight peri-implant fluid was seen in 34,5%, a continuous fringe of fluid at least 1 mm thick in 23,8% and more than 1mm thick in 13,1%. The mean width of the bone beds was 4,38 ± 1,28 mm (apex), 5,41± 1,12 mm (middle) and 5,88 ± 1,39 mm (basis), indicating a widening of 0.33 mm of the basis. The mean length of the bone beds was 19,09 ± 2,38 mm. No significant difference was found between the lateral and medial row or between knotted and knotless implants. No case of gross osteolysis was observed. CONCLUSION: The results of the present study show that biocomposite suture anchors are frequently still visible on MRI 2 years after a rotator cuff reconstruction. No gross osteolysis was observed in the present study, indicating good biocompatibility of the implants. SAGE Publications 2017-07-31 /pmc/articles/PMC5564958/ http://dx.doi.org/10.1177/2325967117S00368 Text en © The Author(s) 2017 http://creativecommons.org/licenses/by-nc-nd/3.0/ This open-access article is published and distributed under the Creative Commons Attribution - NonCommercial - No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article without the permission of the Author(s). For reprints and permission queries, please visit SAGE’s Web site at http://www.sagepub.com/journalsPermissions.nav.
spellingShingle Article
Sgroi, Mirco
Friesz, Theresa
Reichel, Heiko
Kappe, Thomas
Biodegradation of Biocomposite Suture Anchor Implants 2,2 years after Rotator Cuff Repair
title Biodegradation of Biocomposite Suture Anchor Implants 2,2 years after Rotator Cuff Repair
title_full Biodegradation of Biocomposite Suture Anchor Implants 2,2 years after Rotator Cuff Repair
title_fullStr Biodegradation of Biocomposite Suture Anchor Implants 2,2 years after Rotator Cuff Repair
title_full_unstemmed Biodegradation of Biocomposite Suture Anchor Implants 2,2 years after Rotator Cuff Repair
title_short Biodegradation of Biocomposite Suture Anchor Implants 2,2 years after Rotator Cuff Repair
title_sort biodegradation of biocomposite suture anchor implants 2,2 years after rotator cuff repair
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5564958/
http://dx.doi.org/10.1177/2325967117S00368
work_keys_str_mv AT sgroimirco biodegradationofbiocompositesutureanchorimplants22yearsafterrotatorcuffrepair
AT friesztheresa biodegradationofbiocompositesutureanchorimplants22yearsafterrotatorcuffrepair
AT reichelheiko biodegradationofbiocompositesutureanchorimplants22yearsafterrotatorcuffrepair
AT kappethomas biodegradationofbiocompositesutureanchorimplants22yearsafterrotatorcuffrepair