Cargando…

Open Sub-pectoral Biceps Tenodesis: A Biomechanics Comparison Of Interference Screw And Various Fixation Techniques

OBJECTIVES: The purpose of this study was to biomechanically compare six techniques for biceps tenodesis to evaluate the potential difference of anchor size, type and configuration (single- versus double-loaded). The six techniques were interference screws (IS), endobutton (EB), double-loaded 2.9mm...

Descripción completa

Detalles Bibliográficos
Autores principales: Diaz, Miguel, Shi, Brendan, Belkoff, Stephen, Srikumaran, Umasuthan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5565036/
http://dx.doi.org/10.1177/2325967117S00401
_version_ 1783258350739259392
author Diaz, Miguel
Shi, Brendan
Belkoff, Stephen
Srikumaran, Umasuthan
author_facet Diaz, Miguel
Shi, Brendan
Belkoff, Stephen
Srikumaran, Umasuthan
author_sort Diaz, Miguel
collection PubMed
description OBJECTIVES: The purpose of this study was to biomechanically compare six techniques for biceps tenodesis to evaluate the potential difference of anchor size, type and configuration (single- versus double-loaded). The six techniques were interference screws (IS), endobutton (EB), double-loaded 2.9mm PEEK anchor (DL-2.9), double-loaded 1.9mm all-suture anchor (DL-1.9), single-loaded 1.7mm all-suture anchor (SL-1.7), and soft tissue tenodesis (ST) (Smith and Nephew, Memphis, TN, USA). METHODS: 42 fresh-frozen cadaver shoulders (mean age, 72 years [range 54 to 89 years; SD, 9.8 years]; 71% male specimens) were dissected leaving the proximal humerus, proximal biceps tendon, and pectorals major insertion. Specimens were randomized 1 to 6 groups and a sub-pectoral biceps tenodesis was performed. The specimens underwent load to failure axial traction on a materials testing machine. RESULTS: The mean failure loads with the 95%Cl are as follows: IS (78.6N, 58.1-99.1 N), ST (100.3 N, 77.7-122.9 N), DL-1.9 (120.6 N, 101.3-139.8 N), EB (136.7 N, 104.5-168.9 N), DL-2.9 (141.0 N, 111.3-170.7 N), and SL-1.7 (142.0 N, 107.9-176.1 N). Failure occurred at the tendon in almost all specimens, however 5 specimens sustained anchor failure during mechanical loading (IS, n=2; DL-2.9, n=1; DL-1.9, n=1; SL-1.7, n=1). CONCLUSION: The load to failure testing of the interference screw group demonstrated statistically significant lower results than the endobutton and anchor techniques. The endobutton and anchor techniques were not significantly different. The endobutton, double-loaded 2.9mm PEEK anchor, and single-loaded 1.7mm all-suture anchor attained the largest ultimate failure loads at approximately 140 N. These results may be taken into consideration when the orthopedic surgeon selects the appropriate fixation technique.
format Online
Article
Text
id pubmed-5565036
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-55650362017-08-24 Open Sub-pectoral Biceps Tenodesis: A Biomechanics Comparison Of Interference Screw And Various Fixation Techniques Diaz, Miguel Shi, Brendan Belkoff, Stephen Srikumaran, Umasuthan Orthop J Sports Med Article OBJECTIVES: The purpose of this study was to biomechanically compare six techniques for biceps tenodesis to evaluate the potential difference of anchor size, type and configuration (single- versus double-loaded). The six techniques were interference screws (IS), endobutton (EB), double-loaded 2.9mm PEEK anchor (DL-2.9), double-loaded 1.9mm all-suture anchor (DL-1.9), single-loaded 1.7mm all-suture anchor (SL-1.7), and soft tissue tenodesis (ST) (Smith and Nephew, Memphis, TN, USA). METHODS: 42 fresh-frozen cadaver shoulders (mean age, 72 years [range 54 to 89 years; SD, 9.8 years]; 71% male specimens) were dissected leaving the proximal humerus, proximal biceps tendon, and pectorals major insertion. Specimens were randomized 1 to 6 groups and a sub-pectoral biceps tenodesis was performed. The specimens underwent load to failure axial traction on a materials testing machine. RESULTS: The mean failure loads with the 95%Cl are as follows: IS (78.6N, 58.1-99.1 N), ST (100.3 N, 77.7-122.9 N), DL-1.9 (120.6 N, 101.3-139.8 N), EB (136.7 N, 104.5-168.9 N), DL-2.9 (141.0 N, 111.3-170.7 N), and SL-1.7 (142.0 N, 107.9-176.1 N). Failure occurred at the tendon in almost all specimens, however 5 specimens sustained anchor failure during mechanical loading (IS, n=2; DL-2.9, n=1; DL-1.9, n=1; SL-1.7, n=1). CONCLUSION: The load to failure testing of the interference screw group demonstrated statistically significant lower results than the endobutton and anchor techniques. The endobutton and anchor techniques were not significantly different. The endobutton, double-loaded 2.9mm PEEK anchor, and single-loaded 1.7mm all-suture anchor attained the largest ultimate failure loads at approximately 140 N. These results may be taken into consideration when the orthopedic surgeon selects the appropriate fixation technique. SAGE Publications 2017-07-31 /pmc/articles/PMC5565036/ http://dx.doi.org/10.1177/2325967117S00401 Text en © The Author(s) 2017 http://creativecommons.org/licenses/by-nc-nd/3.0/ This open-access article is published and distributed under the Creative Commons Attribution - NonCommercial - No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article without the permission of the Author(s). For reprints and permission queries, please visit SAGE’s Web site at http://www.sagepub.com/journalsPermissions.nav.
spellingShingle Article
Diaz, Miguel
Shi, Brendan
Belkoff, Stephen
Srikumaran, Umasuthan
Open Sub-pectoral Biceps Tenodesis: A Biomechanics Comparison Of Interference Screw And Various Fixation Techniques
title Open Sub-pectoral Biceps Tenodesis: A Biomechanics Comparison Of Interference Screw And Various Fixation Techniques
title_full Open Sub-pectoral Biceps Tenodesis: A Biomechanics Comparison Of Interference Screw And Various Fixation Techniques
title_fullStr Open Sub-pectoral Biceps Tenodesis: A Biomechanics Comparison Of Interference Screw And Various Fixation Techniques
title_full_unstemmed Open Sub-pectoral Biceps Tenodesis: A Biomechanics Comparison Of Interference Screw And Various Fixation Techniques
title_short Open Sub-pectoral Biceps Tenodesis: A Biomechanics Comparison Of Interference Screw And Various Fixation Techniques
title_sort open sub-pectoral biceps tenodesis: a biomechanics comparison of interference screw and various fixation techniques
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5565036/
http://dx.doi.org/10.1177/2325967117S00401
work_keys_str_mv AT diazmiguel opensubpectoralbicepstenodesisabiomechanicscomparisonofinterferencescrewandvariousfixationtechniques
AT shibrendan opensubpectoralbicepstenodesisabiomechanicscomparisonofinterferencescrewandvariousfixationtechniques
AT belkoffstephen opensubpectoralbicepstenodesisabiomechanicscomparisonofinterferencescrewandvariousfixationtechniques
AT srikumaranumasuthan opensubpectoralbicepstenodesisabiomechanicscomparisonofinterferencescrewandvariousfixationtechniques