Cargando…

Validation of a new 2-D technique for radiographic wear measurement of cemented, highly cross-linked polyethylene acetabular cups

A new 2-D radiographic wear measurement system has been developed which enables the low wear of highly cross-linked polyethylene acetabular cups to be accurately and precisely measured from standard, pelvis radiographs. The software was validated using radiographic images of a measurement jig which...

Descripción completa

Detalles Bibliográficos
Autores principales: Derbyshire, Brian, Barkatali, Bilal
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Butterworth-Heinemann 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5566276/
https://www.ncbi.nlm.nih.gov/pubmed/28684212
http://dx.doi.org/10.1016/j.medengphy.2017.06.005
_version_ 1783258522433093632
author Derbyshire, Brian
Barkatali, Bilal
author_facet Derbyshire, Brian
Barkatali, Bilal
author_sort Derbyshire, Brian
collection PubMed
description A new 2-D radiographic wear measurement system has been developed which enables the low wear of highly cross-linked polyethylene acetabular cups to be accurately and precisely measured from standard, pelvis radiographs. The software was validated using radiographic images of a measurement jig which could vary the cup orientation and simulate the effect of pelvic tilt/rotation. Wear was simulated using accurately measured plastic shims to vary the position of the femoral head relative to the cup. The effects of varying “wear” penetration, “wear” direction, cup orientation and X-ray focus position were assessed. Further direct comparison tests were also carried out using radiostereometric analysis. Inter/intra-observer repeatability of the new system was assessed using clinical radiographs. The mean (SD) “wear” penetration error was -0.002 mm (0.028 mm). The “wear” penetration precision was 0.055 mm. Changing the position of the X-ray focus point made no difference to the measurement error. Inter/intra-observer repeatability and limits of agreement had similar low values. Comparison tests with RSA showed the accuracy was similar.
format Online
Article
Text
id pubmed-5566276
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Butterworth-Heinemann
record_format MEDLINE/PubMed
spelling pubmed-55662762017-09-01 Validation of a new 2-D technique for radiographic wear measurement of cemented, highly cross-linked polyethylene acetabular cups Derbyshire, Brian Barkatali, Bilal Med Eng Phys Article A new 2-D radiographic wear measurement system has been developed which enables the low wear of highly cross-linked polyethylene acetabular cups to be accurately and precisely measured from standard, pelvis radiographs. The software was validated using radiographic images of a measurement jig which could vary the cup orientation and simulate the effect of pelvic tilt/rotation. Wear was simulated using accurately measured plastic shims to vary the position of the femoral head relative to the cup. The effects of varying “wear” penetration, “wear” direction, cup orientation and X-ray focus position were assessed. Further direct comparison tests were also carried out using radiostereometric analysis. Inter/intra-observer repeatability of the new system was assessed using clinical radiographs. The mean (SD) “wear” penetration error was -0.002 mm (0.028 mm). The “wear” penetration precision was 0.055 mm. Changing the position of the X-ray focus point made no difference to the measurement error. Inter/intra-observer repeatability and limits of agreement had similar low values. Comparison tests with RSA showed the accuracy was similar. Butterworth-Heinemann 2017-09 /pmc/articles/PMC5566276/ /pubmed/28684212 http://dx.doi.org/10.1016/j.medengphy.2017.06.005 Text en © 2017 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Derbyshire, Brian
Barkatali, Bilal
Validation of a new 2-D technique for radiographic wear measurement of cemented, highly cross-linked polyethylene acetabular cups
title Validation of a new 2-D technique for radiographic wear measurement of cemented, highly cross-linked polyethylene acetabular cups
title_full Validation of a new 2-D technique for radiographic wear measurement of cemented, highly cross-linked polyethylene acetabular cups
title_fullStr Validation of a new 2-D technique for radiographic wear measurement of cemented, highly cross-linked polyethylene acetabular cups
title_full_unstemmed Validation of a new 2-D technique for radiographic wear measurement of cemented, highly cross-linked polyethylene acetabular cups
title_short Validation of a new 2-D technique for radiographic wear measurement of cemented, highly cross-linked polyethylene acetabular cups
title_sort validation of a new 2-d technique for radiographic wear measurement of cemented, highly cross-linked polyethylene acetabular cups
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5566276/
https://www.ncbi.nlm.nih.gov/pubmed/28684212
http://dx.doi.org/10.1016/j.medengphy.2017.06.005
work_keys_str_mv AT derbyshirebrian validationofanew2dtechniqueforradiographicwearmeasurementofcementedhighlycrosslinkedpolyethyleneacetabularcups
AT barkatalibilal validationofanew2dtechniqueforradiographicwearmeasurementofcementedhighlycrosslinkedpolyethyleneacetabularcups