Cargando…

Dosimetric evaluation of MobiusFX in the RapidArc delivery quality assurance comparing with 3DVH

The dosimetric characteristics of MobiusFX, which uses the treatment machine log file to calculate the dose inside the patient body, were analyzed for use in the RapidArc delivery quality assurance (DQA) process. The accuracy and usefulness of MobiusFX in clinical cases was evaluated by comparing th...

Descripción completa

Detalles Bibliográficos
Autores principales: Song, Ju-Young, Jeong, Jae-Uk, Yoon, Mee Sun, Ahn, Sung-Ja, Chung, Woong-Ki, Nam, Taek-Keun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5568283/
https://www.ncbi.nlm.nih.gov/pubmed/28832605
http://dx.doi.org/10.1371/journal.pone.0183165
_version_ 1783258828898304000
author Song, Ju-Young
Jeong, Jae-Uk
Yoon, Mee Sun
Ahn, Sung-Ja
Chung, Woong-Ki
Nam, Taek-Keun
author_facet Song, Ju-Young
Jeong, Jae-Uk
Yoon, Mee Sun
Ahn, Sung-Ja
Chung, Woong-Ki
Nam, Taek-Keun
author_sort Song, Ju-Young
collection PubMed
description The dosimetric characteristics of MobiusFX, which uses the treatment machine log file to calculate the dose inside the patient body, were analyzed for use in the RapidArc delivery quality assurance (DQA) process. The accuracy and usefulness of MobiusFX in clinical cases was evaluated by comparing the dose calculated by MobiusFX with that calculated by the conventional measurement dose based program, 3DVH. The results of gamma evaluation with three different criteria (3%–3 mm, 4%–3 mm, 5%–3 mm) were analyzed, and the dose changes were calculated while simulating variable position errors (6 mm, 3 mm) and dosimetric output increases (6%, 3%). Although the doses calculated by each tool were not identical due to differences in the calculation algorithms, the doses calculated by MobiusFX were generally similar to those calculated by 3DVH. Based on these results, MobiusFX exhibited the required accuracy for clinical application. However, it could not determine the dosimetric output variation. It should therefore be considered a supplementary DQA tool that can verify the error in the daily treatment process, but not an ideal DQA tool that can replace conventional measurement based DQA methods.
format Online
Article
Text
id pubmed-5568283
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-55682832017-09-09 Dosimetric evaluation of MobiusFX in the RapidArc delivery quality assurance comparing with 3DVH Song, Ju-Young Jeong, Jae-Uk Yoon, Mee Sun Ahn, Sung-Ja Chung, Woong-Ki Nam, Taek-Keun PLoS One Research Article The dosimetric characteristics of MobiusFX, which uses the treatment machine log file to calculate the dose inside the patient body, were analyzed for use in the RapidArc delivery quality assurance (DQA) process. The accuracy and usefulness of MobiusFX in clinical cases was evaluated by comparing the dose calculated by MobiusFX with that calculated by the conventional measurement dose based program, 3DVH. The results of gamma evaluation with three different criteria (3%–3 mm, 4%–3 mm, 5%–3 mm) were analyzed, and the dose changes were calculated while simulating variable position errors (6 mm, 3 mm) and dosimetric output increases (6%, 3%). Although the doses calculated by each tool were not identical due to differences in the calculation algorithms, the doses calculated by MobiusFX were generally similar to those calculated by 3DVH. Based on these results, MobiusFX exhibited the required accuracy for clinical application. However, it could not determine the dosimetric output variation. It should therefore be considered a supplementary DQA tool that can verify the error in the daily treatment process, but not an ideal DQA tool that can replace conventional measurement based DQA methods. Public Library of Science 2017-08-23 /pmc/articles/PMC5568283/ /pubmed/28832605 http://dx.doi.org/10.1371/journal.pone.0183165 Text en © 2017 Song et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Song, Ju-Young
Jeong, Jae-Uk
Yoon, Mee Sun
Ahn, Sung-Ja
Chung, Woong-Ki
Nam, Taek-Keun
Dosimetric evaluation of MobiusFX in the RapidArc delivery quality assurance comparing with 3DVH
title Dosimetric evaluation of MobiusFX in the RapidArc delivery quality assurance comparing with 3DVH
title_full Dosimetric evaluation of MobiusFX in the RapidArc delivery quality assurance comparing with 3DVH
title_fullStr Dosimetric evaluation of MobiusFX in the RapidArc delivery quality assurance comparing with 3DVH
title_full_unstemmed Dosimetric evaluation of MobiusFX in the RapidArc delivery quality assurance comparing with 3DVH
title_short Dosimetric evaluation of MobiusFX in the RapidArc delivery quality assurance comparing with 3DVH
title_sort dosimetric evaluation of mobiusfx in the rapidarc delivery quality assurance comparing with 3dvh
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5568283/
https://www.ncbi.nlm.nih.gov/pubmed/28832605
http://dx.doi.org/10.1371/journal.pone.0183165
work_keys_str_mv AT songjuyoung dosimetricevaluationofmobiusfxintherapidarcdeliveryqualityassurancecomparingwith3dvh
AT jeongjaeuk dosimetricevaluationofmobiusfxintherapidarcdeliveryqualityassurancecomparingwith3dvh
AT yoonmeesun dosimetricevaluationofmobiusfxintherapidarcdeliveryqualityassurancecomparingwith3dvh
AT ahnsungja dosimetricevaluationofmobiusfxintherapidarcdeliveryqualityassurancecomparingwith3dvh
AT chungwoongki dosimetricevaluationofmobiusfxintherapidarcdeliveryqualityassurancecomparingwith3dvh
AT namtaekkeun dosimetricevaluationofmobiusfxintherapidarcdeliveryqualityassurancecomparingwith3dvh