Cargando…
Dark-blood late gadolinium enhancement without additional magnetization preparation
BACKGROUND: This study evaluates a novel dark-blood late gadolinium enhancement (LGE) cardiovascular magnetic resonance imaging (CMR) method, without using additional magnetization preparation, and compares it to conventional bright-blood LGE, for the detection of ischaemic myocardial scar. LGE is a...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5568308/ https://www.ncbi.nlm.nih.gov/pubmed/28835250 http://dx.doi.org/10.1186/s12968-017-0372-4 |
_version_ | 1783258834774523904 |
---|---|
author | Holtackers, Robert J. Chiribiri, Amedeo Schneider, Torben Higgins, David M. Botnar, René M. |
author_facet | Holtackers, Robert J. Chiribiri, Amedeo Schneider, Torben Higgins, David M. Botnar, René M. |
author_sort | Holtackers, Robert J. |
collection | PubMed |
description | BACKGROUND: This study evaluates a novel dark-blood late gadolinium enhancement (LGE) cardiovascular magnetic resonance imaging (CMR) method, without using additional magnetization preparation, and compares it to conventional bright-blood LGE, for the detection of ischaemic myocardial scar. LGE is able to clearly depict myocardial infarction and macroscopic scarring from viable myocardium. However, due to the bright signal of adjacent left ventricular blood, the apparent volume of scar tissue can be significantly reduced, or even completely obscured. In addition, blood pool signal can mimic scar tissue and lead to false positive observations. Simply nulling the blood magnetization by choosing shorter inversion times, leads to a negative viable myocardium signal that appears equally as bright as scar due to the magnitude image reconstruction. However, by combining blood magnetization nulling with the extended grayscale range of phase-sensitive inversion-recovery (PSIR), a darker blood signal can be achieved whilst a dark myocardium and bright scar signal is preserved. METHODS: LGE was performed in nine male patients (63 ± 11y) using a PSIR pulse sequence, with both conventional viable myocardium nulling and left ventricular blood nulling, in a randomized order. Regions of interest were drawn in the left ventricular blood, viable myocardium, and scar tissue, to assess contrast-to-noise ratios. Maximum scar transmurality, scar size, circumferential scar angle, and a confidence score for scar detection and maximum transmurality were also assessed. Bloch simulations were performed to simulate the magnetization levels of the left ventricular blood, viable myocardium, and scar tissue. RESULTS: Average scar-to-blood contrast was significantly (p < 0.001) increased by 99% when nulling left ventricular blood instead of viable myocardium, while scar-to-myocardium contrast was maintained. Nulling left ventricular blood also led to significantly (p = 0.038) higher expert confidence in scar detection and maximum transmurality. No significant changes were found in scar transmurality (p = 0.317), normalized scar size (p = 0.054), and circumferential scar angle (p = 0.117). CONCLUSIONS: Nulling left ventricular blood magnetization for PSIR LGE leads to improved scar-to-blood contrast and increased expert confidence in scar detection and scar transmurality. As no additional magnetization preparation is used, clinical application on current MR systems is readily available without the need for extensive optimizations, software modifications, and/or additional training. |
format | Online Article Text |
id | pubmed-5568308 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-55683082017-08-29 Dark-blood late gadolinium enhancement without additional magnetization preparation Holtackers, Robert J. Chiribiri, Amedeo Schneider, Torben Higgins, David M. Botnar, René M. J Cardiovasc Magn Reson Technical Notes BACKGROUND: This study evaluates a novel dark-blood late gadolinium enhancement (LGE) cardiovascular magnetic resonance imaging (CMR) method, without using additional magnetization preparation, and compares it to conventional bright-blood LGE, for the detection of ischaemic myocardial scar. LGE is able to clearly depict myocardial infarction and macroscopic scarring from viable myocardium. However, due to the bright signal of adjacent left ventricular blood, the apparent volume of scar tissue can be significantly reduced, or even completely obscured. In addition, blood pool signal can mimic scar tissue and lead to false positive observations. Simply nulling the blood magnetization by choosing shorter inversion times, leads to a negative viable myocardium signal that appears equally as bright as scar due to the magnitude image reconstruction. However, by combining blood magnetization nulling with the extended grayscale range of phase-sensitive inversion-recovery (PSIR), a darker blood signal can be achieved whilst a dark myocardium and bright scar signal is preserved. METHODS: LGE was performed in nine male patients (63 ± 11y) using a PSIR pulse sequence, with both conventional viable myocardium nulling and left ventricular blood nulling, in a randomized order. Regions of interest were drawn in the left ventricular blood, viable myocardium, and scar tissue, to assess contrast-to-noise ratios. Maximum scar transmurality, scar size, circumferential scar angle, and a confidence score for scar detection and maximum transmurality were also assessed. Bloch simulations were performed to simulate the magnetization levels of the left ventricular blood, viable myocardium, and scar tissue. RESULTS: Average scar-to-blood contrast was significantly (p < 0.001) increased by 99% when nulling left ventricular blood instead of viable myocardium, while scar-to-myocardium contrast was maintained. Nulling left ventricular blood also led to significantly (p = 0.038) higher expert confidence in scar detection and maximum transmurality. No significant changes were found in scar transmurality (p = 0.317), normalized scar size (p = 0.054), and circumferential scar angle (p = 0.117). CONCLUSIONS: Nulling left ventricular blood magnetization for PSIR LGE leads to improved scar-to-blood contrast and increased expert confidence in scar detection and scar transmurality. As no additional magnetization preparation is used, clinical application on current MR systems is readily available without the need for extensive optimizations, software modifications, and/or additional training. BioMed Central 2017-08-23 /pmc/articles/PMC5568308/ /pubmed/28835250 http://dx.doi.org/10.1186/s12968-017-0372-4 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Technical Notes Holtackers, Robert J. Chiribiri, Amedeo Schneider, Torben Higgins, David M. Botnar, René M. Dark-blood late gadolinium enhancement without additional magnetization preparation |
title | Dark-blood late gadolinium enhancement without additional magnetization preparation |
title_full | Dark-blood late gadolinium enhancement without additional magnetization preparation |
title_fullStr | Dark-blood late gadolinium enhancement without additional magnetization preparation |
title_full_unstemmed | Dark-blood late gadolinium enhancement without additional magnetization preparation |
title_short | Dark-blood late gadolinium enhancement without additional magnetization preparation |
title_sort | dark-blood late gadolinium enhancement without additional magnetization preparation |
topic | Technical Notes |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5568308/ https://www.ncbi.nlm.nih.gov/pubmed/28835250 http://dx.doi.org/10.1186/s12968-017-0372-4 |
work_keys_str_mv | AT holtackersrobertj darkbloodlategadoliniumenhancementwithoutadditionalmagnetizationpreparation AT chiribiriamedeo darkbloodlategadoliniumenhancementwithoutadditionalmagnetizationpreparation AT schneidertorben darkbloodlategadoliniumenhancementwithoutadditionalmagnetizationpreparation AT higginsdavidm darkbloodlategadoliniumenhancementwithoutadditionalmagnetizationpreparation AT botnarrenem darkbloodlategadoliniumenhancementwithoutadditionalmagnetizationpreparation |