Cargando…

ASIAN EUS CUP: Asian EUS Cup-03: Endoscopic ultrasound-guided biliary drainage with misplaced antegrade stent-repositioned with forceps through obstetric anal sphincter injuries

A 70-year-old woman presented with features of extrahepatic biliary obstruction. Evaluation was suggestive of a locally advanced carcinoma head of the pancreas. Endoscopic retrograde cholangiopancreatography was attempted for relief of cholestatic symptoms; however, the lumen of duodenum in the junc...

Descripción completa

Detalles Bibliográficos
Autores principales: Chowdhury, Sudipta Dhar, Joseph, A. J., Kurien, Reuben Thomas, Dutta, Amit Kumar, David, Deepu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5569850/
http://dx.doi.org/10.4103/2303-9027.212286
_version_ 1783259070184030208
author Chowdhury, Sudipta Dhar
Joseph, A. J.
Kurien, Reuben Thomas
Dutta, Amit Kumar
David, Deepu
author_facet Chowdhury, Sudipta Dhar
Joseph, A. J.
Kurien, Reuben Thomas
Dutta, Amit Kumar
David, Deepu
author_sort Chowdhury, Sudipta Dhar
collection PubMed
description A 70-year-old woman presented with features of extrahepatic biliary obstruction. Evaluation was suggestive of a locally advanced carcinoma head of the pancreas. Endoscopic retrograde cholangiopancreatography was attempted for relief of cholestatic symptoms; however, the lumen of duodenum in the junction between its first and second part was narrowed. This hindered the passage of a side viewing endoscope. Standard forward viewing scope could be passed across and it showed a normal papilla. Endoscopic ultrasound-guided access of the bile duct was planned. The dilated intrahepatic biliary radicle was punctured from the stomach with a 19-gauge needle (Expect – Boston Scientific) and contrast injected. A 0.035 inch guidewire (Visiglide-Olympus Corp., Japan) was then negotiated across the papilla. Over the wire, dilatation of the stricture and the hepaticogastrostomy access point was done using a 4 mm biliary balloon (Hurricane Rx – Boston Scientific). Following this, a fully covered self-expandable metallic stents (WallFlex – Boston Scientific) was placed across the papilla. However, postdeployment, we noted that the proximal flange of the stent had not opened fully and was partly within the stricture segment. OASIS (10 Fr) (Cook Medical) was inserted over the wire inside the bile duct. The guiding catheter was removed and a forceps was inserted through the OASIS, a forceps was inserted. Using the forceps, gentle traction was deployed to pull the stent proximally. The technique illustrates risk of distal deployment of fully covered self-expandable metallic stents during antegrade stenting and the use of OASIS to pass a forceps for pulling the stent proximally.
format Online
Article
Text
id pubmed-5569850
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-55698502017-09-01 ASIAN EUS CUP: Asian EUS Cup-03: Endoscopic ultrasound-guided biliary drainage with misplaced antegrade stent-repositioned with forceps through obstetric anal sphincter injuries Chowdhury, Sudipta Dhar Joseph, A. J. Kurien, Reuben Thomas Dutta, Amit Kumar David, Deepu Endosc Ultrasound Abstract A 70-year-old woman presented with features of extrahepatic biliary obstruction. Evaluation was suggestive of a locally advanced carcinoma head of the pancreas. Endoscopic retrograde cholangiopancreatography was attempted for relief of cholestatic symptoms; however, the lumen of duodenum in the junction between its first and second part was narrowed. This hindered the passage of a side viewing endoscope. Standard forward viewing scope could be passed across and it showed a normal papilla. Endoscopic ultrasound-guided access of the bile duct was planned. The dilated intrahepatic biliary radicle was punctured from the stomach with a 19-gauge needle (Expect – Boston Scientific) and contrast injected. A 0.035 inch guidewire (Visiglide-Olympus Corp., Japan) was then negotiated across the papilla. Over the wire, dilatation of the stricture and the hepaticogastrostomy access point was done using a 4 mm biliary balloon (Hurricane Rx – Boston Scientific). Following this, a fully covered self-expandable metallic stents (WallFlex – Boston Scientific) was placed across the papilla. However, postdeployment, we noted that the proximal flange of the stent had not opened fully and was partly within the stricture segment. OASIS (10 Fr) (Cook Medical) was inserted over the wire inside the bile duct. The guiding catheter was removed and a forceps was inserted through the OASIS, a forceps was inserted. Using the forceps, gentle traction was deployed to pull the stent proximally. The technique illustrates risk of distal deployment of fully covered self-expandable metallic stents during antegrade stenting and the use of OASIS to pass a forceps for pulling the stent proximally. Medknow Publications & Media Pvt Ltd 2017-08 /pmc/articles/PMC5569850/ http://dx.doi.org/10.4103/2303-9027.212286 Text en Copyright: © 2017 Endoscopic Ultrasound http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Abstract
Chowdhury, Sudipta Dhar
Joseph, A. J.
Kurien, Reuben Thomas
Dutta, Amit Kumar
David, Deepu
ASIAN EUS CUP: Asian EUS Cup-03: Endoscopic ultrasound-guided biliary drainage with misplaced antegrade stent-repositioned with forceps through obstetric anal sphincter injuries
title ASIAN EUS CUP: Asian EUS Cup-03: Endoscopic ultrasound-guided biliary drainage with misplaced antegrade stent-repositioned with forceps through obstetric anal sphincter injuries
title_full ASIAN EUS CUP: Asian EUS Cup-03: Endoscopic ultrasound-guided biliary drainage with misplaced antegrade stent-repositioned with forceps through obstetric anal sphincter injuries
title_fullStr ASIAN EUS CUP: Asian EUS Cup-03: Endoscopic ultrasound-guided biliary drainage with misplaced antegrade stent-repositioned with forceps through obstetric anal sphincter injuries
title_full_unstemmed ASIAN EUS CUP: Asian EUS Cup-03: Endoscopic ultrasound-guided biliary drainage with misplaced antegrade stent-repositioned with forceps through obstetric anal sphincter injuries
title_short ASIAN EUS CUP: Asian EUS Cup-03: Endoscopic ultrasound-guided biliary drainage with misplaced antegrade stent-repositioned with forceps through obstetric anal sphincter injuries
title_sort asian eus cup: asian eus cup-03: endoscopic ultrasound-guided biliary drainage with misplaced antegrade stent-repositioned with forceps through obstetric anal sphincter injuries
topic Abstract
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5569850/
http://dx.doi.org/10.4103/2303-9027.212286
work_keys_str_mv AT chowdhurysudiptadhar asianeuscupasianeuscup03endoscopicultrasoundguidedbiliarydrainagewithmisplacedantegradestentrepositionedwithforcepsthroughobstetricanalsphincterinjuries
AT josephaj asianeuscupasianeuscup03endoscopicultrasoundguidedbiliarydrainagewithmisplacedantegradestentrepositionedwithforcepsthroughobstetricanalsphincterinjuries
AT kurienreubenthomas asianeuscupasianeuscup03endoscopicultrasoundguidedbiliarydrainagewithmisplacedantegradestentrepositionedwithforcepsthroughobstetricanalsphincterinjuries
AT duttaamitkumar asianeuscupasianeuscup03endoscopicultrasoundguidedbiliarydrainagewithmisplacedantegradestentrepositionedwithforcepsthroughobstetricanalsphincterinjuries
AT daviddeepu asianeuscupasianeuscup03endoscopicultrasoundguidedbiliarydrainagewithmisplacedantegradestentrepositionedwithforcepsthroughobstetricanalsphincterinjuries