Cargando…

Maternal detection of neonatal jaundice during birth hospitalization using a novel two-color icterometer

BACKGROUND: Mothers are frequently the first to observe the onset of jaundice in their newborn infants before the decision to seek treatment. However, simple-to-use tools that could facilitate early detection of jaundice and assist mothers to seek professional care, especially after hospital dischar...

Descripción completa

Detalles Bibliográficos
Autores principales: Olusanya, Bolajoko O., Slusher, Tina M., Imosemi, Donald O., Emokpae, Abieyuwa A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5570328/
https://www.ncbi.nlm.nih.gov/pubmed/28837635
http://dx.doi.org/10.1371/journal.pone.0183882
_version_ 1783259160640487424
author Olusanya, Bolajoko O.
Slusher, Tina M.
Imosemi, Donald O.
Emokpae, Abieyuwa A.
author_facet Olusanya, Bolajoko O.
Slusher, Tina M.
Imosemi, Donald O.
Emokpae, Abieyuwa A.
author_sort Olusanya, Bolajoko O.
collection PubMed
description BACKGROUND: Mothers are frequently the first to observe the onset of jaundice in their newborn infants before the decision to seek treatment. However, simple-to-use tools that could facilitate early detection of jaundice and assist mothers to seek professional care, especially after hospital discharge, are rare. This study therefore, set out to evaluate the performance of a -two-color icterometer (Bilistrip™) as a possible screening tool for detecting significant jaundice by mothers or care-givers in the first week of life. METHODS: Prior to discharge, mothers in a maternity hospital were trained to use the Bilistrip™ on the blanched skin of their baby’s nose to ascertain absence (Light Yellow) or presence (Dark Yellow) of significant jaundice. Their babies had transcutaneous bilirubin (TcB) measurements independently, along with total serum bilirubin (TSB) if indicated. The reliability of Bilistrip™ as a screening test for significant jaundice was determined at different TcB and TSB thresholds. The predictive performance of Bilistrip™ was also evaluated with multivariable logistic regression. RESULTS: Some 2492 mother-infant pairs were enrolled over 15 months, of which 347 (13.9%) chose Dark Yellow. The mean TcB for Dark Yellow (10mg/dL) was significantly higher (p<0.001) than for Light Yellow (6.1mg/dL). Bilistrip™ showed increasing sensitivity (47.0% - 92.6%) and negative predictive value (NPV) (91.4% - 99.9%) for selected TcB thresholds (≥10mg/dL, ≥12mg/dL, ≥15mg/dL, and ≥17mg/dL). Among neonates with TSB measurements (n = 124), Bilistrip™ was associated also with increasing sensitivity (86.8% - 100%) and NPV (62.5% - 100%). The sensitivity and NPV for detecting neonates requiring phototherapy were 95.8% respectively. Only one of the 24 neonates who required phototherapy was missed by the Bilistrip™. CONCLUSIONS: Bilistrip™ is a potential decision-making tool for empowering mothers to detect neonates with clinically significant jaundice that may require close monitoring or treatment, and neonates not requiring treatment for jaundice in the first week of life.
format Online
Article
Text
id pubmed-5570328
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-55703282017-09-09 Maternal detection of neonatal jaundice during birth hospitalization using a novel two-color icterometer Olusanya, Bolajoko O. Slusher, Tina M. Imosemi, Donald O. Emokpae, Abieyuwa A. PLoS One Research Article BACKGROUND: Mothers are frequently the first to observe the onset of jaundice in their newborn infants before the decision to seek treatment. However, simple-to-use tools that could facilitate early detection of jaundice and assist mothers to seek professional care, especially after hospital discharge, are rare. This study therefore, set out to evaluate the performance of a -two-color icterometer (Bilistrip™) as a possible screening tool for detecting significant jaundice by mothers or care-givers in the first week of life. METHODS: Prior to discharge, mothers in a maternity hospital were trained to use the Bilistrip™ on the blanched skin of their baby’s nose to ascertain absence (Light Yellow) or presence (Dark Yellow) of significant jaundice. Their babies had transcutaneous bilirubin (TcB) measurements independently, along with total serum bilirubin (TSB) if indicated. The reliability of Bilistrip™ as a screening test for significant jaundice was determined at different TcB and TSB thresholds. The predictive performance of Bilistrip™ was also evaluated with multivariable logistic regression. RESULTS: Some 2492 mother-infant pairs were enrolled over 15 months, of which 347 (13.9%) chose Dark Yellow. The mean TcB for Dark Yellow (10mg/dL) was significantly higher (p<0.001) than for Light Yellow (6.1mg/dL). Bilistrip™ showed increasing sensitivity (47.0% - 92.6%) and negative predictive value (NPV) (91.4% - 99.9%) for selected TcB thresholds (≥10mg/dL, ≥12mg/dL, ≥15mg/dL, and ≥17mg/dL). Among neonates with TSB measurements (n = 124), Bilistrip™ was associated also with increasing sensitivity (86.8% - 100%) and NPV (62.5% - 100%). The sensitivity and NPV for detecting neonates requiring phototherapy were 95.8% respectively. Only one of the 24 neonates who required phototherapy was missed by the Bilistrip™. CONCLUSIONS: Bilistrip™ is a potential decision-making tool for empowering mothers to detect neonates with clinically significant jaundice that may require close monitoring or treatment, and neonates not requiring treatment for jaundice in the first week of life. Public Library of Science 2017-08-24 /pmc/articles/PMC5570328/ /pubmed/28837635 http://dx.doi.org/10.1371/journal.pone.0183882 Text en © 2017 Olusanya et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Olusanya, Bolajoko O.
Slusher, Tina M.
Imosemi, Donald O.
Emokpae, Abieyuwa A.
Maternal detection of neonatal jaundice during birth hospitalization using a novel two-color icterometer
title Maternal detection of neonatal jaundice during birth hospitalization using a novel two-color icterometer
title_full Maternal detection of neonatal jaundice during birth hospitalization using a novel two-color icterometer
title_fullStr Maternal detection of neonatal jaundice during birth hospitalization using a novel two-color icterometer
title_full_unstemmed Maternal detection of neonatal jaundice during birth hospitalization using a novel two-color icterometer
title_short Maternal detection of neonatal jaundice during birth hospitalization using a novel two-color icterometer
title_sort maternal detection of neonatal jaundice during birth hospitalization using a novel two-color icterometer
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5570328/
https://www.ncbi.nlm.nih.gov/pubmed/28837635
http://dx.doi.org/10.1371/journal.pone.0183882
work_keys_str_mv AT olusanyabolajokoo maternaldetectionofneonataljaundiceduringbirthhospitalizationusinganoveltwocoloricterometer
AT slushertinam maternaldetectionofneonataljaundiceduringbirthhospitalizationusinganoveltwocoloricterometer
AT imosemidonaldo maternaldetectionofneonataljaundiceduringbirthhospitalizationusinganoveltwocoloricterometer
AT emokpaeabieyuwaa maternaldetectionofneonataljaundiceduringbirthhospitalizationusinganoveltwocoloricterometer