Cargando…
Impact of sheath diameter of different sheath types on vascular complications and mortality in transfemoral TAVI approaches using the Proglide closure device
OBJECTIVE: Evaluation of the impact of the sheath diameter on vascular complications and mortality in transfemoral aortic valve implantation. METHOD: Between 2012 and 2014, 183 patients underwent the procedure using a sheath diameter of 18–24 F. This collective was divided into two groups: group 1,...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5570351/ https://www.ncbi.nlm.nih.gov/pubmed/28837613 http://dx.doi.org/10.1371/journal.pone.0183658 |
_version_ | 1783259166228348928 |
---|---|
author | Dimitriadis, Zisis Scholtz, Werner Ensminger, Stephan M. Piper, Cornelia Bitter, Thomas Wiemer, Marcus Vlachojannis, Marios Börgermann, Jochen Faber, Lothar Horstkotte, Dieter Gummert, Jan Scholtz, Smita |
author_facet | Dimitriadis, Zisis Scholtz, Werner Ensminger, Stephan M. Piper, Cornelia Bitter, Thomas Wiemer, Marcus Vlachojannis, Marios Börgermann, Jochen Faber, Lothar Horstkotte, Dieter Gummert, Jan Scholtz, Smita |
author_sort | Dimitriadis, Zisis |
collection | PubMed |
description | OBJECTIVE: Evaluation of the impact of the sheath diameter on vascular complications and mortality in transfemoral aortic valve implantation. METHOD: Between 2012 and 2014, 183 patients underwent the procedure using a sheath diameter of 18–24 F. This collective was divided into two groups: group 1, with a sheath diameter of 18F (G1, n = 94), consisted of patients with 18F Medtronic Sentrant and 18 F Direct Flow sheaths, and group 2 with a sheath diameter of 19–24 F (G2, n = 89) consisted of patients with Edwards expandable e-sheath and Solopath sheaths. Perclose-Proglide(®) was used as a closure device in all patients. RESULTS: G1 had significantly more female patients (64.9% vs. 46.1% in G2, p = 0.01) and the average BMI was lower (26 ± 4.5% vs. 27.4 ± 4.7%, p = 0.03). There was no significant difference in the incidence of major and minor vascular complications (G1: 12.8% vs. G2: 12.4%, p = 0.9). 30-day mortality was similar in both groups (G1: 6.4 ± 2.5% [95% CI: 0.88–0.98], G2: 3.7 ± 1.9% [95% CI: 0.92–0.99]. The Kaplan Meier analysis of survival revealed no significant differences either. CONCLUSION: The difference in sheath diameter had no effect on either incidence or severity of vascular complications. There was no impact on mortality either. |
format | Online Article Text |
id | pubmed-5570351 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-55703512017-09-09 Impact of sheath diameter of different sheath types on vascular complications and mortality in transfemoral TAVI approaches using the Proglide closure device Dimitriadis, Zisis Scholtz, Werner Ensminger, Stephan M. Piper, Cornelia Bitter, Thomas Wiemer, Marcus Vlachojannis, Marios Börgermann, Jochen Faber, Lothar Horstkotte, Dieter Gummert, Jan Scholtz, Smita PLoS One Research Article OBJECTIVE: Evaluation of the impact of the sheath diameter on vascular complications and mortality in transfemoral aortic valve implantation. METHOD: Between 2012 and 2014, 183 patients underwent the procedure using a sheath diameter of 18–24 F. This collective was divided into two groups: group 1, with a sheath diameter of 18F (G1, n = 94), consisted of patients with 18F Medtronic Sentrant and 18 F Direct Flow sheaths, and group 2 with a sheath diameter of 19–24 F (G2, n = 89) consisted of patients with Edwards expandable e-sheath and Solopath sheaths. Perclose-Proglide(®) was used as a closure device in all patients. RESULTS: G1 had significantly more female patients (64.9% vs. 46.1% in G2, p = 0.01) and the average BMI was lower (26 ± 4.5% vs. 27.4 ± 4.7%, p = 0.03). There was no significant difference in the incidence of major and minor vascular complications (G1: 12.8% vs. G2: 12.4%, p = 0.9). 30-day mortality was similar in both groups (G1: 6.4 ± 2.5% [95% CI: 0.88–0.98], G2: 3.7 ± 1.9% [95% CI: 0.92–0.99]. The Kaplan Meier analysis of survival revealed no significant differences either. CONCLUSION: The difference in sheath diameter had no effect on either incidence or severity of vascular complications. There was no impact on mortality either. Public Library of Science 2017-08-24 /pmc/articles/PMC5570351/ /pubmed/28837613 http://dx.doi.org/10.1371/journal.pone.0183658 Text en © 2017 Dimitriadis et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Dimitriadis, Zisis Scholtz, Werner Ensminger, Stephan M. Piper, Cornelia Bitter, Thomas Wiemer, Marcus Vlachojannis, Marios Börgermann, Jochen Faber, Lothar Horstkotte, Dieter Gummert, Jan Scholtz, Smita Impact of sheath diameter of different sheath types on vascular complications and mortality in transfemoral TAVI approaches using the Proglide closure device |
title | Impact of sheath diameter of different sheath types on vascular complications and mortality in transfemoral TAVI approaches using the Proglide closure device |
title_full | Impact of sheath diameter of different sheath types on vascular complications and mortality in transfemoral TAVI approaches using the Proglide closure device |
title_fullStr | Impact of sheath diameter of different sheath types on vascular complications and mortality in transfemoral TAVI approaches using the Proglide closure device |
title_full_unstemmed | Impact of sheath diameter of different sheath types on vascular complications and mortality in transfemoral TAVI approaches using the Proglide closure device |
title_short | Impact of sheath diameter of different sheath types on vascular complications and mortality in transfemoral TAVI approaches using the Proglide closure device |
title_sort | impact of sheath diameter of different sheath types on vascular complications and mortality in transfemoral tavi approaches using the proglide closure device |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5570351/ https://www.ncbi.nlm.nih.gov/pubmed/28837613 http://dx.doi.org/10.1371/journal.pone.0183658 |
work_keys_str_mv | AT dimitriadiszisis impactofsheathdiameterofdifferentsheathtypesonvascularcomplicationsandmortalityintransfemoraltaviapproachesusingtheproglideclosuredevice AT scholtzwerner impactofsheathdiameterofdifferentsheathtypesonvascularcomplicationsandmortalityintransfemoraltaviapproachesusingtheproglideclosuredevice AT ensmingerstephanm impactofsheathdiameterofdifferentsheathtypesonvascularcomplicationsandmortalityintransfemoraltaviapproachesusingtheproglideclosuredevice AT pipercornelia impactofsheathdiameterofdifferentsheathtypesonvascularcomplicationsandmortalityintransfemoraltaviapproachesusingtheproglideclosuredevice AT bitterthomas impactofsheathdiameterofdifferentsheathtypesonvascularcomplicationsandmortalityintransfemoraltaviapproachesusingtheproglideclosuredevice AT wiemermarcus impactofsheathdiameterofdifferentsheathtypesonvascularcomplicationsandmortalityintransfemoraltaviapproachesusingtheproglideclosuredevice AT vlachojannismarios impactofsheathdiameterofdifferentsheathtypesonvascularcomplicationsandmortalityintransfemoraltaviapproachesusingtheproglideclosuredevice AT borgermannjochen impactofsheathdiameterofdifferentsheathtypesonvascularcomplicationsandmortalityintransfemoraltaviapproachesusingtheproglideclosuredevice AT faberlothar impactofsheathdiameterofdifferentsheathtypesonvascularcomplicationsandmortalityintransfemoraltaviapproachesusingtheproglideclosuredevice AT horstkottedieter impactofsheathdiameterofdifferentsheathtypesonvascularcomplicationsandmortalityintransfemoraltaviapproachesusingtheproglideclosuredevice AT gummertjan impactofsheathdiameterofdifferentsheathtypesonvascularcomplicationsandmortalityintransfemoraltaviapproachesusingtheproglideclosuredevice AT scholtzsmita impactofsheathdiameterofdifferentsheathtypesonvascularcomplicationsandmortalityintransfemoraltaviapproachesusingtheproglideclosuredevice |