Cargando…
The Spanish version of the Patient-Rated Wrist Evaluation outcome measure: cross-cultural adaptation process, reliability, measurement error and construct validity
BACKGROUND: The Patient-Rated Wrist Evaluation (PRWE) is a widely used measure of patient-reported disability and pain related to wrist disorders. We performed cross-cultural adaptation of the PRWE into Spanish (Spain) and assessed reliability and construct validity in patients with distal radius fr...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5571511/ https://www.ncbi.nlm.nih.gov/pubmed/28836994 http://dx.doi.org/10.1186/s12955-017-0745-2 |
_version_ | 1783259354330300416 |
---|---|
author | Rosales, Roberto S. García-Gutierrez, Rayco Reboso-Morales, Luis Atroshi, Isam |
author_facet | Rosales, Roberto S. García-Gutierrez, Rayco Reboso-Morales, Luis Atroshi, Isam |
author_sort | Rosales, Roberto S. |
collection | PubMed |
description | BACKGROUND: The Patient-Rated Wrist Evaluation (PRWE) is a widely used measure of patient-reported disability and pain related to wrist disorders. We performed cross-cultural adaptation of the PRWE into Spanish (Spain) and assessed reliability and construct validity in patients with distal radius fracture. METHODS: Adaptation of the English version to Spanish (Spain) was performed using translation/back translation methodology. The measurement properties of the PRWE-Spanish were assessed in a sample of 40 consecutive patients (31 women), mean age 58 (SD 19) years, with extra-articular distal radius fractures treated with closed reduction and cast. The patients completed the PRWE-Spanish and the standard Spanish versions of the 11-item Disabilities of the Arm, Shoulder and Hand (QuickDASH) and EQ-5D questionnaires at baseline (health status before fracture) and at 8, 9, 12, and 13 weeks after treatment. Internal-consistency reliability was assessed with the Cronbach alpha coefficient and test-retest reliability with the intraclass correlation coefficient (ICC) comparing responses at 8 and 9 weeks and responses at 12 and 13 weeks. Cross-sectional precision was analyzed with the Standard Error of the Measurement (SEM). Longitudinal precision for test-retest reliability coefficient was analyzed with the Standard Error of the Measurement difference (SEMdiff) and the Minimal Detectable Change at 90% (MDC(90)) and 95% (MDC(95)) confidence levels. For assessing construct validity we hypothesized that the PRWE-Spanish (lower score indicates less disability and pain) would have strong positive correlation with the QuickDASH (lower score indicates less disability) and moderate negative correlation with the EQ-5D Index (higher score indicates better health); Spearman correlation coefficient (r) was used. RESULTS: For the PRWE total score, Cronbach alpha was 0.98 (SEM = 2.67) at baseline and 0.96 (SEM = 4.37) at 8 weeks. For test-retest reliability ICC was 0.94 (8 and 9 weeks) and 0.96 (12 and 13 weeks) with SEMdiff 7.61 and 6.18 and MDC(95) 13.74 and 12.11, respectively. The PRWE-Spanish scores had strong positive correlation with the QuickDASH scores at baseline (r = 0.71) and at 8 weeks (r = 0.79) and moderate negative correlation with the EQ-5D Index (r = −0.44 and r = −0.40, respectively). CONCLUSIONS: The PRWE-Spanish showed high internal-consistency and test-retest reliability and good construct validity in patients with distal radius fracture. |
format | Online Article Text |
id | pubmed-5571511 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-55715112017-08-29 The Spanish version of the Patient-Rated Wrist Evaluation outcome measure: cross-cultural adaptation process, reliability, measurement error and construct validity Rosales, Roberto S. García-Gutierrez, Rayco Reboso-Morales, Luis Atroshi, Isam Health Qual Life Outcomes Research BACKGROUND: The Patient-Rated Wrist Evaluation (PRWE) is a widely used measure of patient-reported disability and pain related to wrist disorders. We performed cross-cultural adaptation of the PRWE into Spanish (Spain) and assessed reliability and construct validity in patients with distal radius fracture. METHODS: Adaptation of the English version to Spanish (Spain) was performed using translation/back translation methodology. The measurement properties of the PRWE-Spanish were assessed in a sample of 40 consecutive patients (31 women), mean age 58 (SD 19) years, with extra-articular distal radius fractures treated with closed reduction and cast. The patients completed the PRWE-Spanish and the standard Spanish versions of the 11-item Disabilities of the Arm, Shoulder and Hand (QuickDASH) and EQ-5D questionnaires at baseline (health status before fracture) and at 8, 9, 12, and 13 weeks after treatment. Internal-consistency reliability was assessed with the Cronbach alpha coefficient and test-retest reliability with the intraclass correlation coefficient (ICC) comparing responses at 8 and 9 weeks and responses at 12 and 13 weeks. Cross-sectional precision was analyzed with the Standard Error of the Measurement (SEM). Longitudinal precision for test-retest reliability coefficient was analyzed with the Standard Error of the Measurement difference (SEMdiff) and the Minimal Detectable Change at 90% (MDC(90)) and 95% (MDC(95)) confidence levels. For assessing construct validity we hypothesized that the PRWE-Spanish (lower score indicates less disability and pain) would have strong positive correlation with the QuickDASH (lower score indicates less disability) and moderate negative correlation with the EQ-5D Index (higher score indicates better health); Spearman correlation coefficient (r) was used. RESULTS: For the PRWE total score, Cronbach alpha was 0.98 (SEM = 2.67) at baseline and 0.96 (SEM = 4.37) at 8 weeks. For test-retest reliability ICC was 0.94 (8 and 9 weeks) and 0.96 (12 and 13 weeks) with SEMdiff 7.61 and 6.18 and MDC(95) 13.74 and 12.11, respectively. The PRWE-Spanish scores had strong positive correlation with the QuickDASH scores at baseline (r = 0.71) and at 8 weeks (r = 0.79) and moderate negative correlation with the EQ-5D Index (r = −0.44 and r = −0.40, respectively). CONCLUSIONS: The PRWE-Spanish showed high internal-consistency and test-retest reliability and good construct validity in patients with distal radius fracture. BioMed Central 2017-08-24 /pmc/articles/PMC5571511/ /pubmed/28836994 http://dx.doi.org/10.1186/s12955-017-0745-2 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Rosales, Roberto S. García-Gutierrez, Rayco Reboso-Morales, Luis Atroshi, Isam The Spanish version of the Patient-Rated Wrist Evaluation outcome measure: cross-cultural adaptation process, reliability, measurement error and construct validity |
title | The Spanish version of the Patient-Rated Wrist Evaluation outcome measure: cross-cultural adaptation process, reliability, measurement error and construct validity |
title_full | The Spanish version of the Patient-Rated Wrist Evaluation outcome measure: cross-cultural adaptation process, reliability, measurement error and construct validity |
title_fullStr | The Spanish version of the Patient-Rated Wrist Evaluation outcome measure: cross-cultural adaptation process, reliability, measurement error and construct validity |
title_full_unstemmed | The Spanish version of the Patient-Rated Wrist Evaluation outcome measure: cross-cultural adaptation process, reliability, measurement error and construct validity |
title_short | The Spanish version of the Patient-Rated Wrist Evaluation outcome measure: cross-cultural adaptation process, reliability, measurement error and construct validity |
title_sort | spanish version of the patient-rated wrist evaluation outcome measure: cross-cultural adaptation process, reliability, measurement error and construct validity |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5571511/ https://www.ncbi.nlm.nih.gov/pubmed/28836994 http://dx.doi.org/10.1186/s12955-017-0745-2 |
work_keys_str_mv | AT rosalesrobertos thespanishversionofthepatientratedwristevaluationoutcomemeasurecrossculturaladaptationprocessreliabilitymeasurementerrorandconstructvalidity AT garciagutierrezrayco thespanishversionofthepatientratedwristevaluationoutcomemeasurecrossculturaladaptationprocessreliabilitymeasurementerrorandconstructvalidity AT rebosomoralesluis thespanishversionofthepatientratedwristevaluationoutcomemeasurecrossculturaladaptationprocessreliabilitymeasurementerrorandconstructvalidity AT atroshiisam thespanishversionofthepatientratedwristevaluationoutcomemeasurecrossculturaladaptationprocessreliabilitymeasurementerrorandconstructvalidity AT rosalesrobertos spanishversionofthepatientratedwristevaluationoutcomemeasurecrossculturaladaptationprocessreliabilitymeasurementerrorandconstructvalidity AT garciagutierrezrayco spanishversionofthepatientratedwristevaluationoutcomemeasurecrossculturaladaptationprocessreliabilitymeasurementerrorandconstructvalidity AT rebosomoralesluis spanishversionofthepatientratedwristevaluationoutcomemeasurecrossculturaladaptationprocessreliabilitymeasurementerrorandconstructvalidity AT atroshiisam spanishversionofthepatientratedwristevaluationoutcomemeasurecrossculturaladaptationprocessreliabilitymeasurementerrorandconstructvalidity |