Cargando…

Physiological Responses to Firefighting in Extreme Temperatures Do Not Compare to Firefighting in Temperate Conditions

Purpose: The aim of this study was to examine physiological responses to two different simulated firefighting exercises: a firefighting exercise with flashovers, smoke, poor visibility and extreme temperatures (300°) in a burning container and a standard firefighting exercise in temperate conditions...

Descripción completa

Detalles Bibliográficos
Autores principales: Windisch, Stephanie, Seiberl, Wolfgang, Hahn, Daniel, Schwirtz, Ansgar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5572164/
https://www.ncbi.nlm.nih.gov/pubmed/28878694
http://dx.doi.org/10.3389/fphys.2017.00619
_version_ 1783259474675367936
author Windisch, Stephanie
Seiberl, Wolfgang
Hahn, Daniel
Schwirtz, Ansgar
author_facet Windisch, Stephanie
Seiberl, Wolfgang
Hahn, Daniel
Schwirtz, Ansgar
author_sort Windisch, Stephanie
collection PubMed
description Purpose: The aim of this study was to examine physiological responses to two different simulated firefighting exercises: a firefighting exercise with flashovers, smoke, poor visibility and extreme temperatures (300°) in a burning container and a standard firefighting exercise in temperate conditions. Furthermore, a second purpose of the study was to find out if the contribution of strength and endurance capacities to firefighting performance changes when the demands of the firefighting exercise change. Methods: Sixteen professional firefighters performed a maximum treadmill test, strength testing, a standard simulated firefighting exercise (SFE) without heat and flashovers and a firefighting exercise with a simulation of the flashover phenomenon in a burning container (FOT). The treadmill testing was used to determine peak oxygen uptake (VO(2peak)), ventilatory threshold (VT1) and respiratory compensation point (RCP). Three intensity zones were identified according to heart rate (HR) values corresponding to VT1 and RCP: zone 1–HR below VT1, zone 2-HR between VT1 and RCP, zone 3–HR above RCP. Firefighting performance was determined by a simple time-strain-air depletion model (TSA) taking the sum of z-transformed parameters of time to finish the exercise, strain in terms of mean heart rate, and air depletion from the breathing apparatus. Correlations were then established between TSA based firefighting performance parameters and fitness variables representing strength and endurance. Results: HR was significantly lower during SFE (79.9 ± 6.9%HR(max)) compared to FOT (85.4 ± 5.2%HR(max)). During SFE subjects spent 24.6 ± 30.2% of time in zone 1, 65.8 ± 28.1% in zone 2 and 9.7 ± 16.6% in zone 3. During FOT subjects spent 16.3 ± 12.8% in zone 1, 50.4 ± 13.2% in zone 2 and 33.3 ± 16.6% in zone 3. Out of all correlations, relative VO(2peak) showed the highest relation to mean HR during SFE (−0.593) as well as FOT (−0.693). Conclusions: Endurance in terms of VO(2peak) is an important prerequisite for both firefighting exercises. However, for standard simulated firefighting exercises it is important to work below VT1. For firefighting exercises in extreme temperatures with smoke, poor visibility and unexpected flashovers a high fitness level is required in order to keep the time spent above RCP as short as possible.
format Online
Article
Text
id pubmed-5572164
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-55721642017-09-06 Physiological Responses to Firefighting in Extreme Temperatures Do Not Compare to Firefighting in Temperate Conditions Windisch, Stephanie Seiberl, Wolfgang Hahn, Daniel Schwirtz, Ansgar Front Physiol Physiology Purpose: The aim of this study was to examine physiological responses to two different simulated firefighting exercises: a firefighting exercise with flashovers, smoke, poor visibility and extreme temperatures (300°) in a burning container and a standard firefighting exercise in temperate conditions. Furthermore, a second purpose of the study was to find out if the contribution of strength and endurance capacities to firefighting performance changes when the demands of the firefighting exercise change. Methods: Sixteen professional firefighters performed a maximum treadmill test, strength testing, a standard simulated firefighting exercise (SFE) without heat and flashovers and a firefighting exercise with a simulation of the flashover phenomenon in a burning container (FOT). The treadmill testing was used to determine peak oxygen uptake (VO(2peak)), ventilatory threshold (VT1) and respiratory compensation point (RCP). Three intensity zones were identified according to heart rate (HR) values corresponding to VT1 and RCP: zone 1–HR below VT1, zone 2-HR between VT1 and RCP, zone 3–HR above RCP. Firefighting performance was determined by a simple time-strain-air depletion model (TSA) taking the sum of z-transformed parameters of time to finish the exercise, strain in terms of mean heart rate, and air depletion from the breathing apparatus. Correlations were then established between TSA based firefighting performance parameters and fitness variables representing strength and endurance. Results: HR was significantly lower during SFE (79.9 ± 6.9%HR(max)) compared to FOT (85.4 ± 5.2%HR(max)). During SFE subjects spent 24.6 ± 30.2% of time in zone 1, 65.8 ± 28.1% in zone 2 and 9.7 ± 16.6% in zone 3. During FOT subjects spent 16.3 ± 12.8% in zone 1, 50.4 ± 13.2% in zone 2 and 33.3 ± 16.6% in zone 3. Out of all correlations, relative VO(2peak) showed the highest relation to mean HR during SFE (−0.593) as well as FOT (−0.693). Conclusions: Endurance in terms of VO(2peak) is an important prerequisite for both firefighting exercises. However, for standard simulated firefighting exercises it is important to work below VT1. For firefighting exercises in extreme temperatures with smoke, poor visibility and unexpected flashovers a high fitness level is required in order to keep the time spent above RCP as short as possible. Frontiers Media S.A. 2017-08-23 /pmc/articles/PMC5572164/ /pubmed/28878694 http://dx.doi.org/10.3389/fphys.2017.00619 Text en Copyright © 2017 Windisch, Seiberl, Hahn and Schwirtz. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Windisch, Stephanie
Seiberl, Wolfgang
Hahn, Daniel
Schwirtz, Ansgar
Physiological Responses to Firefighting in Extreme Temperatures Do Not Compare to Firefighting in Temperate Conditions
title Physiological Responses to Firefighting in Extreme Temperatures Do Not Compare to Firefighting in Temperate Conditions
title_full Physiological Responses to Firefighting in Extreme Temperatures Do Not Compare to Firefighting in Temperate Conditions
title_fullStr Physiological Responses to Firefighting in Extreme Temperatures Do Not Compare to Firefighting in Temperate Conditions
title_full_unstemmed Physiological Responses to Firefighting in Extreme Temperatures Do Not Compare to Firefighting in Temperate Conditions
title_short Physiological Responses to Firefighting in Extreme Temperatures Do Not Compare to Firefighting in Temperate Conditions
title_sort physiological responses to firefighting in extreme temperatures do not compare to firefighting in temperate conditions
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5572164/
https://www.ncbi.nlm.nih.gov/pubmed/28878694
http://dx.doi.org/10.3389/fphys.2017.00619
work_keys_str_mv AT windischstephanie physiologicalresponsestofirefightinginextremetemperaturesdonotcomparetofirefightingintemperateconditions
AT seiberlwolfgang physiologicalresponsestofirefightinginextremetemperaturesdonotcomparetofirefightingintemperateconditions
AT hahndaniel physiologicalresponsestofirefightinginextremetemperaturesdonotcomparetofirefightingintemperateconditions
AT schwirtzansgar physiologicalresponsestofirefightinginextremetemperaturesdonotcomparetofirefightingintemperateconditions