Cargando…
Evaluation of the Elecsys syphilis immunoassay for routine screening of serum samples in China
We compared the performance of the Roche Diagnostics Elecsys immunoassay for the detection of Treponema pallidum specific antibodies in patient serum samples with that of the Abbott Laboratories Architect chemiluminescent microparticle immunoassay and the InTec and KHB enzyme-linked immunosorbent as...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5572731/ https://www.ncbi.nlm.nih.gov/pubmed/28842664 http://dx.doi.org/10.1038/s41598-017-10103-9 |
_version_ | 1783259564731269120 |
---|---|
author | Tao, Chuanmin Hao, Xiaoke Xu, Wei Zhang, Jie Pan, Shiyang Tao, Zhihua Li, Xiaofei Chen, Junmei Zhang, Bingchang Qiu, Yurong Wu, Yanan Ou, Qishui Huang, Xianzhang Wang, Lanlan |
author_facet | Tao, Chuanmin Hao, Xiaoke Xu, Wei Zhang, Jie Pan, Shiyang Tao, Zhihua Li, Xiaofei Chen, Junmei Zhang, Bingchang Qiu, Yurong Wu, Yanan Ou, Qishui Huang, Xianzhang Wang, Lanlan |
author_sort | Tao, Chuanmin |
collection | PubMed |
description | We compared the performance of the Roche Diagnostics Elecsys immunoassay for the detection of Treponema pallidum specific antibodies in patient serum samples with that of the Abbott Laboratories Architect chemiluminescent microparticle immunoassay and the InTec and KHB enzyme-linked immunosorbent assays, which are commonly used in China. We tested 13,767 serum samples collected from 13 independent laboratories throughout China, which included samples from 999 previously confirmed syphilis cases and 158 ‘borderline’ samples previously identified using the Architect, InTec, and KHB tests. The Mikrogen Syphilis Immunoblot was used to confirm positive test results. The consistency between the four different assays was 100%. The sensitivity of Elecsys immunoassay was 100% versus 98.26% for Architect, 99.11% for InTec; and 98.56% for KHB. The specificity of the Elecsys immunoassay was 99.81% versus 99.74% for Architect; 99.93% versus 99.80% for InTec; and 99.85% versus 99.77% for KHB. For borderline samples, the Elecsys immunoassay yielded no false-negative results and fewer false-positive results, compared to the other tests. Considering the ease-of-use, automation, high speed, and high throughput capacity of the Elecsys assay, the higher sensitivity and specificity indicate it is superior for routine screening of serum samples for syphilis diagnosis. |
format | Online Article Text |
id | pubmed-5572731 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-55727312017-09-01 Evaluation of the Elecsys syphilis immunoassay for routine screening of serum samples in China Tao, Chuanmin Hao, Xiaoke Xu, Wei Zhang, Jie Pan, Shiyang Tao, Zhihua Li, Xiaofei Chen, Junmei Zhang, Bingchang Qiu, Yurong Wu, Yanan Ou, Qishui Huang, Xianzhang Wang, Lanlan Sci Rep Article We compared the performance of the Roche Diagnostics Elecsys immunoassay for the detection of Treponema pallidum specific antibodies in patient serum samples with that of the Abbott Laboratories Architect chemiluminescent microparticle immunoassay and the InTec and KHB enzyme-linked immunosorbent assays, which are commonly used in China. We tested 13,767 serum samples collected from 13 independent laboratories throughout China, which included samples from 999 previously confirmed syphilis cases and 158 ‘borderline’ samples previously identified using the Architect, InTec, and KHB tests. The Mikrogen Syphilis Immunoblot was used to confirm positive test results. The consistency between the four different assays was 100%. The sensitivity of Elecsys immunoassay was 100% versus 98.26% for Architect, 99.11% for InTec; and 98.56% for KHB. The specificity of the Elecsys immunoassay was 99.81% versus 99.74% for Architect; 99.93% versus 99.80% for InTec; and 99.85% versus 99.77% for KHB. For borderline samples, the Elecsys immunoassay yielded no false-negative results and fewer false-positive results, compared to the other tests. Considering the ease-of-use, automation, high speed, and high throughput capacity of the Elecsys assay, the higher sensitivity and specificity indicate it is superior for routine screening of serum samples for syphilis diagnosis. Nature Publishing Group UK 2017-08-25 /pmc/articles/PMC5572731/ /pubmed/28842664 http://dx.doi.org/10.1038/s41598-017-10103-9 Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Tao, Chuanmin Hao, Xiaoke Xu, Wei Zhang, Jie Pan, Shiyang Tao, Zhihua Li, Xiaofei Chen, Junmei Zhang, Bingchang Qiu, Yurong Wu, Yanan Ou, Qishui Huang, Xianzhang Wang, Lanlan Evaluation of the Elecsys syphilis immunoassay for routine screening of serum samples in China |
title | Evaluation of the Elecsys syphilis immunoassay for routine screening of serum samples in China |
title_full | Evaluation of the Elecsys syphilis immunoassay for routine screening of serum samples in China |
title_fullStr | Evaluation of the Elecsys syphilis immunoassay for routine screening of serum samples in China |
title_full_unstemmed | Evaluation of the Elecsys syphilis immunoassay for routine screening of serum samples in China |
title_short | Evaluation of the Elecsys syphilis immunoassay for routine screening of serum samples in China |
title_sort | evaluation of the elecsys syphilis immunoassay for routine screening of serum samples in china |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5572731/ https://www.ncbi.nlm.nih.gov/pubmed/28842664 http://dx.doi.org/10.1038/s41598-017-10103-9 |
work_keys_str_mv | AT taochuanmin evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina AT haoxiaoke evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina AT xuwei evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina AT zhangjie evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina AT panshiyang evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina AT taozhihua evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina AT lixiaofei evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina AT chenjunmei evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina AT zhangbingchang evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina AT qiuyurong evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina AT wuyanan evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina AT ouqishui evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina AT huangxianzhang evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina AT wanglanlan evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina |