Cargando…

Evaluation of the Elecsys syphilis immunoassay for routine screening of serum samples in China

We compared the performance of the Roche Diagnostics Elecsys immunoassay for the detection of Treponema pallidum specific antibodies in patient serum samples with that of the Abbott Laboratories Architect chemiluminescent microparticle immunoassay and the InTec and KHB enzyme-linked immunosorbent as...

Descripción completa

Detalles Bibliográficos
Autores principales: Tao, Chuanmin, Hao, Xiaoke, Xu, Wei, Zhang, Jie, Pan, Shiyang, Tao, Zhihua, Li, Xiaofei, Chen, Junmei, Zhang, Bingchang, Qiu, Yurong, Wu, Yanan, Ou, Qishui, Huang, Xianzhang, Wang, Lanlan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5572731/
https://www.ncbi.nlm.nih.gov/pubmed/28842664
http://dx.doi.org/10.1038/s41598-017-10103-9
_version_ 1783259564731269120
author Tao, Chuanmin
Hao, Xiaoke
Xu, Wei
Zhang, Jie
Pan, Shiyang
Tao, Zhihua
Li, Xiaofei
Chen, Junmei
Zhang, Bingchang
Qiu, Yurong
Wu, Yanan
Ou, Qishui
Huang, Xianzhang
Wang, Lanlan
author_facet Tao, Chuanmin
Hao, Xiaoke
Xu, Wei
Zhang, Jie
Pan, Shiyang
Tao, Zhihua
Li, Xiaofei
Chen, Junmei
Zhang, Bingchang
Qiu, Yurong
Wu, Yanan
Ou, Qishui
Huang, Xianzhang
Wang, Lanlan
author_sort Tao, Chuanmin
collection PubMed
description We compared the performance of the Roche Diagnostics Elecsys immunoassay for the detection of Treponema pallidum specific antibodies in patient serum samples with that of the Abbott Laboratories Architect chemiluminescent microparticle immunoassay and the InTec and KHB enzyme-linked immunosorbent assays, which are commonly used in China. We tested 13,767 serum samples collected from 13 independent laboratories throughout China, which included samples from 999 previously confirmed syphilis cases and 158 ‘borderline’ samples previously identified using the Architect, InTec, and KHB tests. The Mikrogen Syphilis Immunoblot was used to confirm positive test results. The consistency between the four different assays was 100%. The sensitivity of Elecsys immunoassay was 100% versus 98.26% for Architect, 99.11% for InTec; and 98.56% for KHB. The specificity of the Elecsys immunoassay was 99.81% versus 99.74% for Architect; 99.93% versus 99.80% for InTec; and 99.85% versus 99.77% for KHB. For borderline samples, the Elecsys immunoassay yielded no false-negative results and fewer false-positive results, compared to the other tests. Considering the ease-of-use, automation, high speed, and high throughput capacity of the Elecsys assay, the higher sensitivity and specificity indicate it is superior for routine screening of serum samples for syphilis diagnosis.
format Online
Article
Text
id pubmed-5572731
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-55727312017-09-01 Evaluation of the Elecsys syphilis immunoassay for routine screening of serum samples in China Tao, Chuanmin Hao, Xiaoke Xu, Wei Zhang, Jie Pan, Shiyang Tao, Zhihua Li, Xiaofei Chen, Junmei Zhang, Bingchang Qiu, Yurong Wu, Yanan Ou, Qishui Huang, Xianzhang Wang, Lanlan Sci Rep Article We compared the performance of the Roche Diagnostics Elecsys immunoassay for the detection of Treponema pallidum specific antibodies in patient serum samples with that of the Abbott Laboratories Architect chemiluminescent microparticle immunoassay and the InTec and KHB enzyme-linked immunosorbent assays, which are commonly used in China. We tested 13,767 serum samples collected from 13 independent laboratories throughout China, which included samples from 999 previously confirmed syphilis cases and 158 ‘borderline’ samples previously identified using the Architect, InTec, and KHB tests. The Mikrogen Syphilis Immunoblot was used to confirm positive test results. The consistency between the four different assays was 100%. The sensitivity of Elecsys immunoassay was 100% versus 98.26% for Architect, 99.11% for InTec; and 98.56% for KHB. The specificity of the Elecsys immunoassay was 99.81% versus 99.74% for Architect; 99.93% versus 99.80% for InTec; and 99.85% versus 99.77% for KHB. For borderline samples, the Elecsys immunoassay yielded no false-negative results and fewer false-positive results, compared to the other tests. Considering the ease-of-use, automation, high speed, and high throughput capacity of the Elecsys assay, the higher sensitivity and specificity indicate it is superior for routine screening of serum samples for syphilis diagnosis. Nature Publishing Group UK 2017-08-25 /pmc/articles/PMC5572731/ /pubmed/28842664 http://dx.doi.org/10.1038/s41598-017-10103-9 Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Tao, Chuanmin
Hao, Xiaoke
Xu, Wei
Zhang, Jie
Pan, Shiyang
Tao, Zhihua
Li, Xiaofei
Chen, Junmei
Zhang, Bingchang
Qiu, Yurong
Wu, Yanan
Ou, Qishui
Huang, Xianzhang
Wang, Lanlan
Evaluation of the Elecsys syphilis immunoassay for routine screening of serum samples in China
title Evaluation of the Elecsys syphilis immunoassay for routine screening of serum samples in China
title_full Evaluation of the Elecsys syphilis immunoassay for routine screening of serum samples in China
title_fullStr Evaluation of the Elecsys syphilis immunoassay for routine screening of serum samples in China
title_full_unstemmed Evaluation of the Elecsys syphilis immunoassay for routine screening of serum samples in China
title_short Evaluation of the Elecsys syphilis immunoassay for routine screening of serum samples in China
title_sort evaluation of the elecsys syphilis immunoassay for routine screening of serum samples in china
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5572731/
https://www.ncbi.nlm.nih.gov/pubmed/28842664
http://dx.doi.org/10.1038/s41598-017-10103-9
work_keys_str_mv AT taochuanmin evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina
AT haoxiaoke evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina
AT xuwei evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina
AT zhangjie evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina
AT panshiyang evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina
AT taozhihua evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina
AT lixiaofei evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina
AT chenjunmei evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina
AT zhangbingchang evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina
AT qiuyurong evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina
AT wuyanan evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina
AT ouqishui evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina
AT huangxianzhang evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina
AT wanglanlan evaluationoftheelecsyssyphilisimmunoassayforroutinescreeningofserumsamplesinchina