Measurement of Milwaukee Brace Pad Pressure in Adolescent Round Back Deformity Treatment

STUDY DESIGN: In this prospective study, we measured the pad pressures of the Milwaukee brace in adolescent hyperkyphosis treatment. PURPOSE: We evaluated the skin-brace interface forces exerted by the main pads of the Milwaukee brace. OVERVIEW OF LITERATURE: A fundamental factor associated with bra...

Descripción completa

Detalles Bibliográficos
Autores principales: Babaee, Taher, Kamyab, Mojtaba, Ahmadi, Amir, Sanjari, Mohammad Ali, Ganjavian, Mohammad Saleh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Spine Surgery 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5573858/
https://www.ncbi.nlm.nih.gov/pubmed/28874982
http://dx.doi.org/10.4184/asj.2017.11.4.627
_version_ 1783259726509768704
author Babaee, Taher
Kamyab, Mojtaba
Ahmadi, Amir
Sanjari, Mohammad Ali
Ganjavian, Mohammad Saleh
author_facet Babaee, Taher
Kamyab, Mojtaba
Ahmadi, Amir
Sanjari, Mohammad Ali
Ganjavian, Mohammad Saleh
author_sort Babaee, Taher
collection PubMed
description STUDY DESIGN: In this prospective study, we measured the pad pressures of the Milwaukee brace in adolescent hyperkyphosis treatment. PURPOSE: We evaluated the skin-brace interface forces exerted by the main pads of the Milwaukee brace. OVERVIEW OF LITERATURE: A fundamental factor associated with brace effectiveness in spinal deformity is pad force adjustment. However, few studies have evaluated the in-brace force magnitude and its effect on curve correction. METHODS: Interface forces at four pads of the Milwaukee brace were measured in 73 patients withround back deformity (mean age, 14.04±1.97 years [range, 10–18]; mean initial Cobb angle,67.70°±9.23° [range, 50°–86°]). We used a modified aneroid sphygmomanometer to measure the shoulder and kyphosis pad pressures. Each patient underwent measurement in the standing and sitting positions during inhalation/exhalation. RESULTS: The mean pad pressures were significantly higher in the standing than in thesitting position, and significantly higher pressures were observed during inhalation compared toexhalation (p=0.001).There were no statistically significant differences between right and left shoulder pad pressures (p>0.05); however, the pressure differences between the right and left kyphosis pads were statistically significant (p<0.05). In a comparison of corrective forces with bracing for less or more than 6 months, corrective force was larger with bracing for less than 6 months (p=0.02). In the standing position, there were no statistically significant correlations between pad pressures and kyphosis curve correction. CONCLUSIONS: In the sitting position, there was a trend toward lower forces at the skin-brace interface; therefore, brace adjustment in the standing position may be useful and more effective. There was no significant correlation between the magnitude of the pad pressures and the degree of in-brace curve correction.
format Online
Article
Text
id pubmed-5573858
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Korean Society of Spine Surgery
record_format MEDLINE/PubMed
spelling pubmed-55738582017-09-05 Measurement of Milwaukee Brace Pad Pressure in Adolescent Round Back Deformity Treatment Babaee, Taher Kamyab, Mojtaba Ahmadi, Amir Sanjari, Mohammad Ali Ganjavian, Mohammad Saleh Asian Spine J Clinical Study STUDY DESIGN: In this prospective study, we measured the pad pressures of the Milwaukee brace in adolescent hyperkyphosis treatment. PURPOSE: We evaluated the skin-brace interface forces exerted by the main pads of the Milwaukee brace. OVERVIEW OF LITERATURE: A fundamental factor associated with brace effectiveness in spinal deformity is pad force adjustment. However, few studies have evaluated the in-brace force magnitude and its effect on curve correction. METHODS: Interface forces at four pads of the Milwaukee brace were measured in 73 patients withround back deformity (mean age, 14.04±1.97 years [range, 10–18]; mean initial Cobb angle,67.70°±9.23° [range, 50°–86°]). We used a modified aneroid sphygmomanometer to measure the shoulder and kyphosis pad pressures. Each patient underwent measurement in the standing and sitting positions during inhalation/exhalation. RESULTS: The mean pad pressures were significantly higher in the standing than in thesitting position, and significantly higher pressures were observed during inhalation compared toexhalation (p=0.001).There were no statistically significant differences between right and left shoulder pad pressures (p>0.05); however, the pressure differences between the right and left kyphosis pads were statistically significant (p<0.05). In a comparison of corrective forces with bracing for less or more than 6 months, corrective force was larger with bracing for less than 6 months (p=0.02). In the standing position, there were no statistically significant correlations between pad pressures and kyphosis curve correction. CONCLUSIONS: In the sitting position, there was a trend toward lower forces at the skin-brace interface; therefore, brace adjustment in the standing position may be useful and more effective. There was no significant correlation between the magnitude of the pad pressures and the degree of in-brace curve correction. Korean Society of Spine Surgery 2017-08 2017-08-07 /pmc/articles/PMC5573858/ /pubmed/28874982 http://dx.doi.org/10.4184/asj.2017.11.4.627 Text en Copyright © 2017 by Korean Society of Spine Surgery http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Babaee, Taher
Kamyab, Mojtaba
Ahmadi, Amir
Sanjari, Mohammad Ali
Ganjavian, Mohammad Saleh
Measurement of Milwaukee Brace Pad Pressure in Adolescent Round Back Deformity Treatment
title Measurement of Milwaukee Brace Pad Pressure in Adolescent Round Back Deformity Treatment
title_full Measurement of Milwaukee Brace Pad Pressure in Adolescent Round Back Deformity Treatment
title_fullStr Measurement of Milwaukee Brace Pad Pressure in Adolescent Round Back Deformity Treatment
title_full_unstemmed Measurement of Milwaukee Brace Pad Pressure in Adolescent Round Back Deformity Treatment
title_short Measurement of Milwaukee Brace Pad Pressure in Adolescent Round Back Deformity Treatment
title_sort measurement of milwaukee brace pad pressure in adolescent round back deformity treatment
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5573858/
https://www.ncbi.nlm.nih.gov/pubmed/28874982
http://dx.doi.org/10.4184/asj.2017.11.4.627
work_keys_str_mv AT babaeetaher measurementofmilwaukeebracepadpressureinadolescentroundbackdeformitytreatment
AT kamyabmojtaba measurementofmilwaukeebracepadpressureinadolescentroundbackdeformitytreatment
AT ahmadiamir measurementofmilwaukeebracepadpressureinadolescentroundbackdeformitytreatment
AT sanjarimohammadali measurementofmilwaukeebracepadpressureinadolescentroundbackdeformitytreatment
AT ganjavianmohammadsaleh measurementofmilwaukeebracepadpressureinadolescentroundbackdeformitytreatment