The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis
OBJECTIVES: Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microsc...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5574505/ https://www.ncbi.nlm.nih.gov/pubmed/28856199 http://dx.doi.org/10.1016/j.plabm.2016.03.002 |
_version_ | 1783259853294141440 |
---|---|
author | İnce, Fatma Demet Ellidağ, Hamit Yaşar Koseoğlu, Mehmet Şimşek, Neşe Yalçın, Hülya Zengin, Mustafa Osman |
author_facet | İnce, Fatma Demet Ellidağ, Hamit Yaşar Koseoğlu, Mehmet Şimşek, Neşe Yalçın, Hülya Zengin, Mustafa Osman |
author_sort | İnce, Fatma Demet |
collection | PubMed |
description | OBJECTIVES: Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. DESIGN AND METHODS: 209 urine samples were analyzed by the Iris iQ200 ELITE (İris Diagnostics, USA), Dirui FUS-200 (DIRUI Industrial Co., China) automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient) and the rates within the same grading were evaluated. RESULTS: For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. CONCLUSION: The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals) have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization. |
format | Online Article Text |
id | pubmed-5574505 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-55745052017-08-30 The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis İnce, Fatma Demet Ellidağ, Hamit Yaşar Koseoğlu, Mehmet Şimşek, Neşe Yalçın, Hülya Zengin, Mustafa Osman Pract Lab Med Article OBJECTIVES: Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. DESIGN AND METHODS: 209 urine samples were analyzed by the Iris iQ200 ELITE (İris Diagnostics, USA), Dirui FUS-200 (DIRUI Industrial Co., China) automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient) and the rates within the same grading were evaluated. RESULTS: For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. CONCLUSION: The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals) have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization. Elsevier 2016-03-11 /pmc/articles/PMC5574505/ /pubmed/28856199 http://dx.doi.org/10.1016/j.plabm.2016.03.002 Text en © 2016 Published by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Article İnce, Fatma Demet Ellidağ, Hamit Yaşar Koseoğlu, Mehmet Şimşek, Neşe Yalçın, Hülya Zengin, Mustafa Osman The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis |
title | The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis |
title_full | The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis |
title_fullStr | The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis |
title_full_unstemmed | The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis |
title_short | The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis |
title_sort | comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5574505/ https://www.ncbi.nlm.nih.gov/pubmed/28856199 http://dx.doi.org/10.1016/j.plabm.2016.03.002 |
work_keys_str_mv | AT incefatmademet thecomparisonofautomatedurineanalyzerswithmanualmicroscopicexaminationforurinalysisautomatedurineanalyzersandmanualurinalysis AT ellidaghamityasar thecomparisonofautomatedurineanalyzerswithmanualmicroscopicexaminationforurinalysisautomatedurineanalyzersandmanualurinalysis AT koseoglumehmet thecomparisonofautomatedurineanalyzerswithmanualmicroscopicexaminationforurinalysisautomatedurineanalyzersandmanualurinalysis AT simseknese thecomparisonofautomatedurineanalyzerswithmanualmicroscopicexaminationforurinalysisautomatedurineanalyzersandmanualurinalysis AT yalcınhulya thecomparisonofautomatedurineanalyzerswithmanualmicroscopicexaminationforurinalysisautomatedurineanalyzersandmanualurinalysis AT zenginmustafaosman thecomparisonofautomatedurineanalyzerswithmanualmicroscopicexaminationforurinalysisautomatedurineanalyzersandmanualurinalysis AT incefatmademet comparisonofautomatedurineanalyzerswithmanualmicroscopicexaminationforurinalysisautomatedurineanalyzersandmanualurinalysis AT ellidaghamityasar comparisonofautomatedurineanalyzerswithmanualmicroscopicexaminationforurinalysisautomatedurineanalyzersandmanualurinalysis AT koseoglumehmet comparisonofautomatedurineanalyzerswithmanualmicroscopicexaminationforurinalysisautomatedurineanalyzersandmanualurinalysis AT simseknese comparisonofautomatedurineanalyzerswithmanualmicroscopicexaminationforurinalysisautomatedurineanalyzersandmanualurinalysis AT yalcınhulya comparisonofautomatedurineanalyzerswithmanualmicroscopicexaminationforurinalysisautomatedurineanalyzersandmanualurinalysis AT zenginmustafaosman comparisonofautomatedurineanalyzerswithmanualmicroscopicexaminationforurinalysisautomatedurineanalyzersandmanualurinalysis |