Filling in the gaps with non-standard body fluids()

OBJECTIVES: Body fluid specimens other than serum, plasma or urine are generally not validated by manufacturers, but analysis of these non-standard fluids can be important for clinical diagnosis and management. Laboratories, therefore, rely on the published literature to better understand the valida...

Descripción completa

Detalles Bibliográficos
Autores principales: Lo, Sheng-Ying, Saifee, Nabiha H., Mason, Brook O., Greene, Dina N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5574517/
https://www.ncbi.nlm.nih.gov/pubmed/28856201
http://dx.doi.org/10.1016/j.plabm.2016.03.003
_version_ 1783259856153608192
author Lo, Sheng-Ying
Saifee, Nabiha H.
Mason, Brook O.
Greene, Dina N.
author_facet Lo, Sheng-Ying
Saifee, Nabiha H.
Mason, Brook O.
Greene, Dina N.
author_sort Lo, Sheng-Ying
collection PubMed
description OBJECTIVES: Body fluid specimens other than serum, plasma or urine are generally not validated by manufacturers, but analysis of these non-standard fluids can be important for clinical diagnosis and management. Laboratories, therefore, rely on the published literature to better understand the validation and implementation of such tests. This study utilized a data-driven approach to determine the clinical reportable range for 11 analytes, evaluated a total bilirubin assay, and assessed interferences from hemolysis, icterus, and lipemia in non-standard fluids. DESIGN AND METHODS: Historical measurements in non-standard body fluids run on a Beckman Coulter DxC800 were used to optimize population-specific clinical reportable ranges for albumin, amylase, creatinine, glucose, lactate dehydrogenase, lipase, total bilirubin, total cholesterol, total protein, triglyceride and urea nitrogen run on the Beckman Coulter AU680. For these 11 analytes, interference studies were performed by spiking hemolysate, bilirubin, or Intralipid® into abnormal serous fluids. Precision, accuracy, linearity, and stability of total bilirubin in non-standard fluids was evaluated on the Beckman Coulter AU680 analyzer. RESULTS: The historical non-standard fluid results indicated that in order to report a numeric result, 4 assays required no dilution, 5 assays required onboard dilutions and 2 assays required both onboard and manual dilutions. The AU680 total bilirubin assay is suitable for clinical testing of non-standard fluids. Interference studies revealed that of the 11 total AU680 analyte measurements on non-standard fluids, lipemia affected 1, icterus affected 3, and hemolysis affected 5. CONCLUSIONS: Chemistry analytes measured on the AU680 demonstrate acceptable analytical performance for non-standard fluids. Common endogenous interference from lipemia, icterus, and hemolysis (LIH) are observed and flagging rules based on LIH indices were developed to help improve the clinical interpretation of results.
format Online
Article
Text
id pubmed-5574517
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-55745172017-08-30 Filling in the gaps with non-standard body fluids() Lo, Sheng-Ying Saifee, Nabiha H. Mason, Brook O. Greene, Dina N. Pract Lab Med Article OBJECTIVES: Body fluid specimens other than serum, plasma or urine are generally not validated by manufacturers, but analysis of these non-standard fluids can be important for clinical diagnosis and management. Laboratories, therefore, rely on the published literature to better understand the validation and implementation of such tests. This study utilized a data-driven approach to determine the clinical reportable range for 11 analytes, evaluated a total bilirubin assay, and assessed interferences from hemolysis, icterus, and lipemia in non-standard fluids. DESIGN AND METHODS: Historical measurements in non-standard body fluids run on a Beckman Coulter DxC800 were used to optimize population-specific clinical reportable ranges for albumin, amylase, creatinine, glucose, lactate dehydrogenase, lipase, total bilirubin, total cholesterol, total protein, triglyceride and urea nitrogen run on the Beckman Coulter AU680. For these 11 analytes, interference studies were performed by spiking hemolysate, bilirubin, or Intralipid® into abnormal serous fluids. Precision, accuracy, linearity, and stability of total bilirubin in non-standard fluids was evaluated on the Beckman Coulter AU680 analyzer. RESULTS: The historical non-standard fluid results indicated that in order to report a numeric result, 4 assays required no dilution, 5 assays required onboard dilutions and 2 assays required both onboard and manual dilutions. The AU680 total bilirubin assay is suitable for clinical testing of non-standard fluids. Interference studies revealed that of the 11 total AU680 analyte measurements on non-standard fluids, lipemia affected 1, icterus affected 3, and hemolysis affected 5. CONCLUSIONS: Chemistry analytes measured on the AU680 demonstrate acceptable analytical performance for non-standard fluids. Common endogenous interference from lipemia, icterus, and hemolysis (LIH) are observed and flagging rules based on LIH indices were developed to help improve the clinical interpretation of results. Elsevier 2016-03-16 /pmc/articles/PMC5574517/ /pubmed/28856201 http://dx.doi.org/10.1016/j.plabm.2016.03.003 Text en © 2016 Published by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Lo, Sheng-Ying
Saifee, Nabiha H.
Mason, Brook O.
Greene, Dina N.
Filling in the gaps with non-standard body fluids()
title Filling in the gaps with non-standard body fluids()
title_full Filling in the gaps with non-standard body fluids()
title_fullStr Filling in the gaps with non-standard body fluids()
title_full_unstemmed Filling in the gaps with non-standard body fluids()
title_short Filling in the gaps with non-standard body fluids()
title_sort filling in the gaps with non-standard body fluids()
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5574517/
https://www.ncbi.nlm.nih.gov/pubmed/28856201
http://dx.doi.org/10.1016/j.plabm.2016.03.003
work_keys_str_mv AT loshengying fillinginthegapswithnonstandardbodyfluids
AT saifeenabihah fillinginthegapswithnonstandardbodyfluids
AT masonbrooko fillinginthegapswithnonstandardbodyfluids
AT greenedinan fillinginthegapswithnonstandardbodyfluids