Cargando…

Minimally-invasive glaucoma surgeries (MIGS) for open angle glaucoma: A systematic review and meta-analysis

BACKGROUND: MIGS have been developed as a surgical alternative for glaucomatous patients. PURPOSE: To analyze the change in intraocular pressure (IOP) and glaucoma medications using different MIGS devices (Trabectome, iStent, Excimer Laser Trabeculotomy (ELT), iStent Supra, CyPass, XEN, Hydrus, Fugo...

Descripción completa

Detalles Bibliográficos
Autores principales: Lavia, Carlo, Dallorto, Laura, Maule, Milena, Ceccarelli, Manuela, Fea, Antonio Maria
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5574616/
https://www.ncbi.nlm.nih.gov/pubmed/28850575
http://dx.doi.org/10.1371/journal.pone.0183142
_version_ 1783259877090525184
author Lavia, Carlo
Dallorto, Laura
Maule, Milena
Ceccarelli, Manuela
Fea, Antonio Maria
author_facet Lavia, Carlo
Dallorto, Laura
Maule, Milena
Ceccarelli, Manuela
Fea, Antonio Maria
author_sort Lavia, Carlo
collection PubMed
description BACKGROUND: MIGS have been developed as a surgical alternative for glaucomatous patients. PURPOSE: To analyze the change in intraocular pressure (IOP) and glaucoma medications using different MIGS devices (Trabectome, iStent, Excimer Laser Trabeculotomy (ELT), iStent Supra, CyPass, XEN, Hydrus, Fugo Blade, Ab interno canaloplasty, Goniscopy-assisted transluminal trabeculotomy) as a solo procedure or in association with phacoemulsification. METHODS: Randomized control trials (RCT) and non-RCT (non randomized comparative studies, NRS, and before-after studies) were included. Studies with at least one year of follow-up in patients affected by primary open angle glaucoma, pseudoexfoliative glaucoma or pigmentary glaucoma were considered. Risk of Bias assessment was performed using the Cochrane Risk of Bias and the ROBINS-I tools. The main outcome was the effect of MIGS devices compared to medical therapy, cataract surgery, other glaucoma surgeries and other MIGS on both IOP and use of glaucoma medications 12 months after surgery. Outcomes measures were the mean difference in the change of IOP and glaucoma medication compared to baseline at one and two years and all ocular adverse events. The current meta-analysis is registered on PROSPERO (reference n° CRD42016037280). RESULTS: Over a total of 3,069 studies, nine RCT and 21 case series with a total of 2.928 eyes were included. Main concerns about risk of bias in RCTs were lack of blinding, allocation concealment and attrition bias while in non-RCTs they were represented by patients’ selection, masking of participants and co-intervention management. Limited evidence was found based on both RCTs and non RCTs that compared MIGS surgery with medical therapy or other MIGS. In before-after series, MIGS surgery seemed effective in lowering both IOP and glaucoma drug use. MIGS showed a good safety profile: IOP spikes were the most frequent complications and no cases of infection or BCVA loss due to glaucoma were reported. CONCLUSIONS: Although MIGS seem efficient in the reduction of the IOP and glaucoma medication and show good safety profile, this evidence is mainly derived from non-comparative studies and further, good quality RCTs are warranted.
format Online
Article
Text
id pubmed-5574616
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-55746162017-09-15 Minimally-invasive glaucoma surgeries (MIGS) for open angle glaucoma: A systematic review and meta-analysis Lavia, Carlo Dallorto, Laura Maule, Milena Ceccarelli, Manuela Fea, Antonio Maria PLoS One Research Article BACKGROUND: MIGS have been developed as a surgical alternative for glaucomatous patients. PURPOSE: To analyze the change in intraocular pressure (IOP) and glaucoma medications using different MIGS devices (Trabectome, iStent, Excimer Laser Trabeculotomy (ELT), iStent Supra, CyPass, XEN, Hydrus, Fugo Blade, Ab interno canaloplasty, Goniscopy-assisted transluminal trabeculotomy) as a solo procedure or in association with phacoemulsification. METHODS: Randomized control trials (RCT) and non-RCT (non randomized comparative studies, NRS, and before-after studies) were included. Studies with at least one year of follow-up in patients affected by primary open angle glaucoma, pseudoexfoliative glaucoma or pigmentary glaucoma were considered. Risk of Bias assessment was performed using the Cochrane Risk of Bias and the ROBINS-I tools. The main outcome was the effect of MIGS devices compared to medical therapy, cataract surgery, other glaucoma surgeries and other MIGS on both IOP and use of glaucoma medications 12 months after surgery. Outcomes measures were the mean difference in the change of IOP and glaucoma medication compared to baseline at one and two years and all ocular adverse events. The current meta-analysis is registered on PROSPERO (reference n° CRD42016037280). RESULTS: Over a total of 3,069 studies, nine RCT and 21 case series with a total of 2.928 eyes were included. Main concerns about risk of bias in RCTs were lack of blinding, allocation concealment and attrition bias while in non-RCTs they were represented by patients’ selection, masking of participants and co-intervention management. Limited evidence was found based on both RCTs and non RCTs that compared MIGS surgery with medical therapy or other MIGS. In before-after series, MIGS surgery seemed effective in lowering both IOP and glaucoma drug use. MIGS showed a good safety profile: IOP spikes were the most frequent complications and no cases of infection or BCVA loss due to glaucoma were reported. CONCLUSIONS: Although MIGS seem efficient in the reduction of the IOP and glaucoma medication and show good safety profile, this evidence is mainly derived from non-comparative studies and further, good quality RCTs are warranted. Public Library of Science 2017-08-29 /pmc/articles/PMC5574616/ /pubmed/28850575 http://dx.doi.org/10.1371/journal.pone.0183142 Text en © 2017 Lavia et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Lavia, Carlo
Dallorto, Laura
Maule, Milena
Ceccarelli, Manuela
Fea, Antonio Maria
Minimally-invasive glaucoma surgeries (MIGS) for open angle glaucoma: A systematic review and meta-analysis
title Minimally-invasive glaucoma surgeries (MIGS) for open angle glaucoma: A systematic review and meta-analysis
title_full Minimally-invasive glaucoma surgeries (MIGS) for open angle glaucoma: A systematic review and meta-analysis
title_fullStr Minimally-invasive glaucoma surgeries (MIGS) for open angle glaucoma: A systematic review and meta-analysis
title_full_unstemmed Minimally-invasive glaucoma surgeries (MIGS) for open angle glaucoma: A systematic review and meta-analysis
title_short Minimally-invasive glaucoma surgeries (MIGS) for open angle glaucoma: A systematic review and meta-analysis
title_sort minimally-invasive glaucoma surgeries (migs) for open angle glaucoma: a systematic review and meta-analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5574616/
https://www.ncbi.nlm.nih.gov/pubmed/28850575
http://dx.doi.org/10.1371/journal.pone.0183142
work_keys_str_mv AT laviacarlo minimallyinvasiveglaucomasurgeriesmigsforopenangleglaucomaasystematicreviewandmetaanalysis
AT dallortolaura minimallyinvasiveglaucomasurgeriesmigsforopenangleglaucomaasystematicreviewandmetaanalysis
AT maulemilena minimallyinvasiveglaucomasurgeriesmigsforopenangleglaucomaasystematicreviewandmetaanalysis
AT ceccarellimanuela minimallyinvasiveglaucomasurgeriesmigsforopenangleglaucomaasystematicreviewandmetaanalysis
AT feaantoniomaria minimallyinvasiveglaucomasurgeriesmigsforopenangleglaucomaasystematicreviewandmetaanalysis