Cargando…

Development and implementation of an HPLC-ECD method for analysis of vitamin C in plasma using single column and automatic alternating dual column regeneration()

OBJECTIVES: Vitamin C (l-ascorbic acid) is a water-soluble micronutrient necessary for human life. Inadequate intake can lead to the fatal disease scurvy. Measurement of vitamin C is used to assess nutritional status and to monitor supplementation. The goal of this study was to develop a chromatogra...

Descripción completa

Detalles Bibliográficos
Autores principales: Clark, Zlatuse D., Frank, Elizabeth L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5574855/
https://www.ncbi.nlm.nih.gov/pubmed/28856210
http://dx.doi.org/10.1016/j.plabm.2016.09.001
Descripción
Sumario:OBJECTIVES: Vitamin C (l-ascorbic acid) is a water-soluble micronutrient necessary for human life. Inadequate intake can lead to the fatal disease scurvy. Measurement of vitamin C is used to assess nutritional status and to monitor supplementation. The goal of this study was to develop a chromatographic method for the quantitation of vitamin C in human plasma. DESIGN AND METHODS: Samples were prepared by protein precipitation, addition of internal standard, and reduction with dithiothreitol. Separation of ascorbic acid was accomplished by isocratic elution on a reverse-phase column; concentration was determined by coulometry. The method was validated through studies of assay linearity, sensitivity, imprecision, accuracy, analytical specificity, and carryover. RESULTS: The new assay was developed using a single pump/single analytical column HPLC system. Results correlated well with our previously used spectrophotometric method. The analytical measurement range was 1.0–2500 µmol/L. The injection-to-injection time was 13 min. Subsequently, to increase method throughput and shorten turnaround time, a dual LC pump system with a 2-position/10-port switching valve capable of performing automatic alternating column regeneration was validated and implemented. The injection-to-injection time was reduced 2-fold to 6 min. The method was linear to 5000 µmol/L; limit of quantification was 1.9 µmol/L. Total imprecision was less than 5%. CONCLUSIONS: We have developed a robust method suitable for routine clinical measurement of vitamin C in plasma specimens. The method incorporates a simplified sample preparation and a stable, non-endogenous internal standard to specifically quantify vitamin C. Faster throughput was achieved by employing an automatic alternating column regeneration system.