Cargando…

Pitfalls of using confocal-microscopy based automated quantification of synaptic complexes in honeybee mushroom bodies (response to Peng and Yang 2016)

A recent study by Peng and Yang in Scientific Reports using confocal-microscopy based automated quantification of anti-synapsin labeled microglomeruli in the mushroom bodies of honeybee brains reports potentially incorrect numbers of microglomerular densities. Whereas several previous studies using...

Descripción completa

Detalles Bibliográficos
Autores principales: Rössler, Wolfgang, Spaethe, Johannes, Groh, Claudia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5575136/
https://www.ncbi.nlm.nih.gov/pubmed/28852015
http://dx.doi.org/10.1038/s41598-017-09967-8
_version_ 1783259981163790336
author Rössler, Wolfgang
Spaethe, Johannes
Groh, Claudia
author_facet Rössler, Wolfgang
Spaethe, Johannes
Groh, Claudia
author_sort Rössler, Wolfgang
collection PubMed
description A recent study by Peng and Yang in Scientific Reports using confocal-microscopy based automated quantification of anti-synapsin labeled microglomeruli in the mushroom bodies of honeybee brains reports potentially incorrect numbers of microglomerular densities. Whereas several previous studies using visually supervised or automated counts from confocal images and analyses of serial 3D electron-microscopy data reported consistent numbers of synaptic complexes per volume, Peng and Yang revealed extremely low numbers differing by a factor of 18 or more from those obtained in visually supervised counts, and by a factor 22–180 from numbers in two other studies using automated counts. This extreme discrepancy is especially disturbing as close comparison of raw confocal images of anti-synapsin labeled whole-mount brain preparations are highly similar across these studies. We conclude that these discrepancies may reside in potential misapplication of confocal imaging followed by erroneous use of automated image analysis software. Consequently, the reported microglomerular densities during maturation and after manipulation by insecticides require validation by application of appropriate confocal imaging methods and analyses tools that rely on skilled observers. We suggest several improvements towards more reliable or standardized automated or semi-automated synapse counts in whole mount preparations of insect brains.
format Online
Article
Text
id pubmed-5575136
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-55751362017-09-01 Pitfalls of using confocal-microscopy based automated quantification of synaptic complexes in honeybee mushroom bodies (response to Peng and Yang 2016) Rössler, Wolfgang Spaethe, Johannes Groh, Claudia Sci Rep Article A recent study by Peng and Yang in Scientific Reports using confocal-microscopy based automated quantification of anti-synapsin labeled microglomeruli in the mushroom bodies of honeybee brains reports potentially incorrect numbers of microglomerular densities. Whereas several previous studies using visually supervised or automated counts from confocal images and analyses of serial 3D electron-microscopy data reported consistent numbers of synaptic complexes per volume, Peng and Yang revealed extremely low numbers differing by a factor of 18 or more from those obtained in visually supervised counts, and by a factor 22–180 from numbers in two other studies using automated counts. This extreme discrepancy is especially disturbing as close comparison of raw confocal images of anti-synapsin labeled whole-mount brain preparations are highly similar across these studies. We conclude that these discrepancies may reside in potential misapplication of confocal imaging followed by erroneous use of automated image analysis software. Consequently, the reported microglomerular densities during maturation and after manipulation by insecticides require validation by application of appropriate confocal imaging methods and analyses tools that rely on skilled observers. We suggest several improvements towards more reliable or standardized automated or semi-automated synapse counts in whole mount preparations of insect brains. Nature Publishing Group UK 2017-08-29 /pmc/articles/PMC5575136/ /pubmed/28852015 http://dx.doi.org/10.1038/s41598-017-09967-8 Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Rössler, Wolfgang
Spaethe, Johannes
Groh, Claudia
Pitfalls of using confocal-microscopy based automated quantification of synaptic complexes in honeybee mushroom bodies (response to Peng and Yang 2016)
title Pitfalls of using confocal-microscopy based automated quantification of synaptic complexes in honeybee mushroom bodies (response to Peng and Yang 2016)
title_full Pitfalls of using confocal-microscopy based automated quantification of synaptic complexes in honeybee mushroom bodies (response to Peng and Yang 2016)
title_fullStr Pitfalls of using confocal-microscopy based automated quantification of synaptic complexes in honeybee mushroom bodies (response to Peng and Yang 2016)
title_full_unstemmed Pitfalls of using confocal-microscopy based automated quantification of synaptic complexes in honeybee mushroom bodies (response to Peng and Yang 2016)
title_short Pitfalls of using confocal-microscopy based automated quantification of synaptic complexes in honeybee mushroom bodies (response to Peng and Yang 2016)
title_sort pitfalls of using confocal-microscopy based automated quantification of synaptic complexes in honeybee mushroom bodies (response to peng and yang 2016)
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5575136/
https://www.ncbi.nlm.nih.gov/pubmed/28852015
http://dx.doi.org/10.1038/s41598-017-09967-8
work_keys_str_mv AT rosslerwolfgang pitfallsofusingconfocalmicroscopybasedautomatedquantificationofsynapticcomplexesinhoneybeemushroombodiesresponsetopengandyang2016
AT spaethejohannes pitfallsofusingconfocalmicroscopybasedautomatedquantificationofsynapticcomplexesinhoneybeemushroombodiesresponsetopengandyang2016
AT grohclaudia pitfallsofusingconfocalmicroscopybasedautomatedquantificationofsynapticcomplexesinhoneybeemushroombodiesresponsetopengandyang2016