Cargando…

Analytical verification and quality assessment of the Tosoh HLC-723GX HbA(1c) analyzer

OBJECTIVES: Ion-exchange high-performance liquid chromatography (IE-HPLC) has long been used as a reproducible and versatile analytical tool for HbA(1c) measurement. In this study, we performed analytical verification and quality assessment of the recently introduced small IE-HPLC Tosoh HLC-723GX Hb...

Descripción completa

Detalles Bibliográficos
Autores principales: Ris, Marko, Božičević, Sandra, Biljak, Vanja Radišić, Vučić Lovrenčić, Marijana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5575365/
https://www.ncbi.nlm.nih.gov/pubmed/28856213
http://dx.doi.org/10.1016/j.plabm.2016.12.001
_version_ 1783260028728246272
author Ris, Marko
Božičević, Sandra
Biljak, Vanja Radišić
Vučić Lovrenčić, Marijana
author_facet Ris, Marko
Božičević, Sandra
Biljak, Vanja Radišić
Vučić Lovrenčić, Marijana
author_sort Ris, Marko
collection PubMed
description OBJECTIVES: Ion-exchange high-performance liquid chromatography (IE-HPLC) has long been used as a reproducible and versatile analytical tool for HbA(1c) measurement. In this study, we performed analytical verification and quality assessment of the recently introduced small IE-HPLC Tosoh HLC-723GX HbA(1c) analyzer, and a comparison of results to immunoassay (IA) and capillary electrophoresis (CE). DESIGN AND METHODS: The total imprecision of Tosoh HLC-723GX was verified according to CLSI EP15-A2 protocol using commercial control materials (C-QC) and pooled human whole blood samples (HWB). The Sigma metric was used for the evaluation of quality targets. HbA(1c) results were compared to automated CE (MiniCap Flex Piercing, Sebia, France) and IA (Tina-quant HbA(1c) Gen 2, Cobas Integra 400+, Roche Diagnostics, USA) procedures. RESULTS: The total imprecision of Tosoh HLC-723GX-HbA(1c) for IFCC(mmol/mol) and NGSP(%) units was: 1.91/1.25% (HbA(1c)=31 mmol/mol/5.0%) and 0.51/0.63% (HbA(1c)=84 mmol/mol/9.8%) for C-QC, and 0.39/0.2% (HbA(1c)=47 mmol/mol/6.5%) and 0.77/0.46% (HbA(1c)=94 mmol/mol/10.8%) in HWB samples, respectively. Bland-Altman analysis did not reveal any deviation of the results between Tosoh HLC-723GX and CE: mean difference 0.0% (95%CI: −0.02927 to 0.02653%), while the mean HbA(1c) difference against IA was −0.07% (95%CI: −0.1039 to −0.02765). At the selected HbA(1c) clinical decision level (48 mmol/mol/6,5%), six sigma analysis gave σ value of 3.91, within a desirable classification of performance. CONCLUSION: The analytical performance of the Tosoh HLC-723GX complies with the rigorous quality criteria for clinical use of HbA(1c), with the results comparable to the CE procedure. Tosoh HLC-723GX provides a plausible analytical choice for reliable HbA(1c) measurement in low-volume laboratories.
format Online
Article
Text
id pubmed-5575365
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-55753652017-08-30 Analytical verification and quality assessment of the Tosoh HLC-723GX HbA(1c) analyzer Ris, Marko Božičević, Sandra Biljak, Vanja Radišić Vučić Lovrenčić, Marijana Pract Lab Med Article OBJECTIVES: Ion-exchange high-performance liquid chromatography (IE-HPLC) has long been used as a reproducible and versatile analytical tool for HbA(1c) measurement. In this study, we performed analytical verification and quality assessment of the recently introduced small IE-HPLC Tosoh HLC-723GX HbA(1c) analyzer, and a comparison of results to immunoassay (IA) and capillary electrophoresis (CE). DESIGN AND METHODS: The total imprecision of Tosoh HLC-723GX was verified according to CLSI EP15-A2 protocol using commercial control materials (C-QC) and pooled human whole blood samples (HWB). The Sigma metric was used for the evaluation of quality targets. HbA(1c) results were compared to automated CE (MiniCap Flex Piercing, Sebia, France) and IA (Tina-quant HbA(1c) Gen 2, Cobas Integra 400+, Roche Diagnostics, USA) procedures. RESULTS: The total imprecision of Tosoh HLC-723GX-HbA(1c) for IFCC(mmol/mol) and NGSP(%) units was: 1.91/1.25% (HbA(1c)=31 mmol/mol/5.0%) and 0.51/0.63% (HbA(1c)=84 mmol/mol/9.8%) for C-QC, and 0.39/0.2% (HbA(1c)=47 mmol/mol/6.5%) and 0.77/0.46% (HbA(1c)=94 mmol/mol/10.8%) in HWB samples, respectively. Bland-Altman analysis did not reveal any deviation of the results between Tosoh HLC-723GX and CE: mean difference 0.0% (95%CI: −0.02927 to 0.02653%), while the mean HbA(1c) difference against IA was −0.07% (95%CI: −0.1039 to −0.02765). At the selected HbA(1c) clinical decision level (48 mmol/mol/6,5%), six sigma analysis gave σ value of 3.91, within a desirable classification of performance. CONCLUSION: The analytical performance of the Tosoh HLC-723GX complies with the rigorous quality criteria for clinical use of HbA(1c), with the results comparable to the CE procedure. Tosoh HLC-723GX provides a plausible analytical choice for reliable HbA(1c) measurement in low-volume laboratories. Elsevier 2016-12-09 /pmc/articles/PMC5575365/ /pubmed/28856213 http://dx.doi.org/10.1016/j.plabm.2016.12.001 Text en © 2016 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Ris, Marko
Božičević, Sandra
Biljak, Vanja Radišić
Vučić Lovrenčić, Marijana
Analytical verification and quality assessment of the Tosoh HLC-723GX HbA(1c) analyzer
title Analytical verification and quality assessment of the Tosoh HLC-723GX HbA(1c) analyzer
title_full Analytical verification and quality assessment of the Tosoh HLC-723GX HbA(1c) analyzer
title_fullStr Analytical verification and quality assessment of the Tosoh HLC-723GX HbA(1c) analyzer
title_full_unstemmed Analytical verification and quality assessment of the Tosoh HLC-723GX HbA(1c) analyzer
title_short Analytical verification and quality assessment of the Tosoh HLC-723GX HbA(1c) analyzer
title_sort analytical verification and quality assessment of the tosoh hlc-723gx hba(1c) analyzer
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5575365/
https://www.ncbi.nlm.nih.gov/pubmed/28856213
http://dx.doi.org/10.1016/j.plabm.2016.12.001
work_keys_str_mv AT rismarko analyticalverificationandqualityassessmentofthetosohhlc723gxhba1canalyzer
AT bozicevicsandra analyticalverificationandqualityassessmentofthetosohhlc723gxhba1canalyzer
AT biljakvanjaradisic analyticalverificationandqualityassessmentofthetosohhlc723gxhba1canalyzer
AT vuciclovrencicmarijana analyticalverificationandqualityassessmentofthetosohhlc723gxhba1canalyzer