Impact of serum-clot contact time on lactate dehydrogenase and inorganic phosphorus serum levels

OBJECTIVES: The aim of this study is to determine the longest acceptable serum-clot contact time before centrifugation in lactate dehydrogenase and inorganic phosphorus analysis. MATERIALS AND METHODS: The LDH and inorganic phosphorus serum levels from 103 adults were analyzed at three different sto...

Descripción completa

Detalles Bibliográficos
Autores principales: Bausset, Olivier, Juvet, Olivier, Staller-Gobelli, Caroline, Milano, Emilie, Bausset, Jean-Paul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5575367/
https://www.ncbi.nlm.nih.gov/pubmed/28856216
http://dx.doi.org/10.1016/j.plabm.2017.01.002
_version_ 1783260028971515904
author Bausset, Olivier
Juvet, Olivier
Staller-Gobelli, Caroline
Milano, Emilie
Bausset, Jean-Paul
author_facet Bausset, Olivier
Juvet, Olivier
Staller-Gobelli, Caroline
Milano, Emilie
Bausset, Jean-Paul
author_sort Bausset, Olivier
collection PubMed
description OBJECTIVES: The aim of this study is to determine the longest acceptable serum-clot contact time before centrifugation in lactate dehydrogenase and inorganic phosphorus analysis. MATERIALS AND METHODS: The LDH and inorganic phosphorus serum levels from 103 adults were analyzed at three different storage times. The three measures were done immediately (T0), after a 2-h serum-clot contact (T2) and after a 4-h serum-clot contact (T4). A paired two-tailed Student t-test evaluated the impact of the serum-clot contact time on the serum levels. Another approach using analytical reproducibly and intra-individual variability was used. Furthermore, we have compared the mean percentage deviation to the measurement uncertainty. RESULTS: The LDH serum level is not significantly impacted by the three different studied serum-clot contact times. The immediate Phosphorus serum level is not significantly different from the 2-h serum-clot contact condition. However, after a 4-h serum-clot contact, the phosphorus serum level is significantly lower than the immediate phosphorus serum level. Considering the reference change value approach, an acceptable mean variation was shown for inorganic phosphorus serum level after a 4-h serum-clot contact time. After a 4-h serum-clot contact, LDH and phosphorus mean percentage deviation are below our measurement uncertainties. CONCLUSION: This study evidences that in our daily practices a 4-h serum-clot contact time for LDH and inorganic phosphorus analysis is acceptable.
format Online
Article
Text
id pubmed-5575367
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-55753672017-08-30 Impact of serum-clot contact time on lactate dehydrogenase and inorganic phosphorus serum levels Bausset, Olivier Juvet, Olivier Staller-Gobelli, Caroline Milano, Emilie Bausset, Jean-Paul Pract Lab Med Article OBJECTIVES: The aim of this study is to determine the longest acceptable serum-clot contact time before centrifugation in lactate dehydrogenase and inorganic phosphorus analysis. MATERIALS AND METHODS: The LDH and inorganic phosphorus serum levels from 103 adults were analyzed at three different storage times. The three measures were done immediately (T0), after a 2-h serum-clot contact (T2) and after a 4-h serum-clot contact (T4). A paired two-tailed Student t-test evaluated the impact of the serum-clot contact time on the serum levels. Another approach using analytical reproducibly and intra-individual variability was used. Furthermore, we have compared the mean percentage deviation to the measurement uncertainty. RESULTS: The LDH serum level is not significantly impacted by the three different studied serum-clot contact times. The immediate Phosphorus serum level is not significantly different from the 2-h serum-clot contact condition. However, after a 4-h serum-clot contact, the phosphorus serum level is significantly lower than the immediate phosphorus serum level. Considering the reference change value approach, an acceptable mean variation was shown for inorganic phosphorus serum level after a 4-h serum-clot contact time. After a 4-h serum-clot contact, LDH and phosphorus mean percentage deviation are below our measurement uncertainties. CONCLUSION: This study evidences that in our daily practices a 4-h serum-clot contact time for LDH and inorganic phosphorus analysis is acceptable. Elsevier 2017-02-03 /pmc/articles/PMC5575367/ /pubmed/28856216 http://dx.doi.org/10.1016/j.plabm.2017.01.002 Text en © 2017 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Bausset, Olivier
Juvet, Olivier
Staller-Gobelli, Caroline
Milano, Emilie
Bausset, Jean-Paul
Impact of serum-clot contact time on lactate dehydrogenase and inorganic phosphorus serum levels
title Impact of serum-clot contact time on lactate dehydrogenase and inorganic phosphorus serum levels
title_full Impact of serum-clot contact time on lactate dehydrogenase and inorganic phosphorus serum levels
title_fullStr Impact of serum-clot contact time on lactate dehydrogenase and inorganic phosphorus serum levels
title_full_unstemmed Impact of serum-clot contact time on lactate dehydrogenase and inorganic phosphorus serum levels
title_short Impact of serum-clot contact time on lactate dehydrogenase and inorganic phosphorus serum levels
title_sort impact of serum-clot contact time on lactate dehydrogenase and inorganic phosphorus serum levels
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5575367/
https://www.ncbi.nlm.nih.gov/pubmed/28856216
http://dx.doi.org/10.1016/j.plabm.2017.01.002
work_keys_str_mv AT baussetolivier impactofserumclotcontacttimeonlactatedehydrogenaseandinorganicphosphorusserumlevels
AT juvetolivier impactofserumclotcontacttimeonlactatedehydrogenaseandinorganicphosphorusserumlevels
AT stallergobellicaroline impactofserumclotcontacttimeonlactatedehydrogenaseandinorganicphosphorusserumlevels
AT milanoemilie impactofserumclotcontacttimeonlactatedehydrogenaseandinorganicphosphorusserumlevels
AT baussetjeanpaul impactofserumclotcontacttimeonlactatedehydrogenaseandinorganicphosphorusserumlevels