Cargando…

Operational impact of using a vanadate oxidase method for direct bilirubin measurements at an academic medical center clinical laboratory

OBJECTIVES: The aim of this study was to compare the operational impact of using vanadate oxidase versus diazo direct bilirubin assays for an academic medical center patient population. DESIGN AND METHODS: Retrospective study was done over an approximately 3.5 year period. The main automated chemist...

Descripción completa

Detalles Bibliográficos
Autores principales: Dhungana, Neha, Morris, Cory, Krasowski, Matthew D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5575373/
https://www.ncbi.nlm.nih.gov/pubmed/28856232
http://dx.doi.org/10.1016/j.plabm.2017.05.004
_version_ 1783260030416453632
author Dhungana, Neha
Morris, Cory
Krasowski, Matthew D.
author_facet Dhungana, Neha
Morris, Cory
Krasowski, Matthew D.
author_sort Dhungana, Neha
collection PubMed
description OBJECTIVES: The aim of this study was to compare the operational impact of using vanadate oxidase versus diazo direct bilirubin assays for an academic medical center patient population. DESIGN AND METHODS: Retrospective study was done over an approximately 3.5 year period. The main automated chemistry instrumentation was a Roche Diagnostics cobas 8000 line. The Roche Direct Bilirubin assay was compared to Diazyme Laboratories Direct Bilirubin Assay and Randox Laboratories Direct Bilirubin assay using manufacturer's guidelines for hemolysis index, lipemia index, and analytical measurement range (AMR). RESULTS: Retrospective data was analyzed for 47,333 serum/plasma specimens that had clinical orders for direct bilirubin. A total of 5943 specimens (12.6%) exceeded the hemolysis index limit for the Roche method compared to only 0.2% and 0.05% of specimens for the Diazyme and Randox methods, respectively. The impact was particularly large on patients less than 2 years old, for which 51.3% of specimens exceeded the hemolysis index for the Roche method. A total of 1671 specimens (3.5%) exceeded the lipemia index limit for the Roche method compared to less than 0.1% for the Randox method. Lastly, 988 (2.1%) of specimens had direct bilirubin concentrations exceeding the upper AMR limit of 10 mg/dL [171 µmol/L] for the Roche assay compared to less than 1% of specimens for the vanadate oxidase methods. CONCLUSIONS: Vanadate oxidase direct bilirubin methods offer advantages over diazo methods in terms of less interference by hemolysis and lipemia, as well as wider AMR. The advantages are particularly evident for neonatal and infant populations.
format Online
Article
Text
id pubmed-5575373
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-55753732017-08-30 Operational impact of using a vanadate oxidase method for direct bilirubin measurements at an academic medical center clinical laboratory Dhungana, Neha Morris, Cory Krasowski, Matthew D. Pract Lab Med Article OBJECTIVES: The aim of this study was to compare the operational impact of using vanadate oxidase versus diazo direct bilirubin assays for an academic medical center patient population. DESIGN AND METHODS: Retrospective study was done over an approximately 3.5 year period. The main automated chemistry instrumentation was a Roche Diagnostics cobas 8000 line. The Roche Direct Bilirubin assay was compared to Diazyme Laboratories Direct Bilirubin Assay and Randox Laboratories Direct Bilirubin assay using manufacturer's guidelines for hemolysis index, lipemia index, and analytical measurement range (AMR). RESULTS: Retrospective data was analyzed for 47,333 serum/plasma specimens that had clinical orders for direct bilirubin. A total of 5943 specimens (12.6%) exceeded the hemolysis index limit for the Roche method compared to only 0.2% and 0.05% of specimens for the Diazyme and Randox methods, respectively. The impact was particularly large on patients less than 2 years old, for which 51.3% of specimens exceeded the hemolysis index for the Roche method. A total of 1671 specimens (3.5%) exceeded the lipemia index limit for the Roche method compared to less than 0.1% for the Randox method. Lastly, 988 (2.1%) of specimens had direct bilirubin concentrations exceeding the upper AMR limit of 10 mg/dL [171 µmol/L] for the Roche assay compared to less than 1% of specimens for the vanadate oxidase methods. CONCLUSIONS: Vanadate oxidase direct bilirubin methods offer advantages over diazo methods in terms of less interference by hemolysis and lipemia, as well as wider AMR. The advantages are particularly evident for neonatal and infant populations. Elsevier 2017-05-17 /pmc/articles/PMC5575373/ /pubmed/28856232 http://dx.doi.org/10.1016/j.plabm.2017.05.004 Text en © 2017 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Dhungana, Neha
Morris, Cory
Krasowski, Matthew D.
Operational impact of using a vanadate oxidase method for direct bilirubin measurements at an academic medical center clinical laboratory
title Operational impact of using a vanadate oxidase method for direct bilirubin measurements at an academic medical center clinical laboratory
title_full Operational impact of using a vanadate oxidase method for direct bilirubin measurements at an academic medical center clinical laboratory
title_fullStr Operational impact of using a vanadate oxidase method for direct bilirubin measurements at an academic medical center clinical laboratory
title_full_unstemmed Operational impact of using a vanadate oxidase method for direct bilirubin measurements at an academic medical center clinical laboratory
title_short Operational impact of using a vanadate oxidase method for direct bilirubin measurements at an academic medical center clinical laboratory
title_sort operational impact of using a vanadate oxidase method for direct bilirubin measurements at an academic medical center clinical laboratory
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5575373/
https://www.ncbi.nlm.nih.gov/pubmed/28856232
http://dx.doi.org/10.1016/j.plabm.2017.05.004
work_keys_str_mv AT dhungananeha operationalimpactofusingavanadateoxidasemethodfordirectbilirubinmeasurementsatanacademicmedicalcenterclinicallaboratory
AT morriscory operationalimpactofusingavanadateoxidasemethodfordirectbilirubinmeasurementsatanacademicmedicalcenterclinicallaboratory
AT krasowskimatthewd operationalimpactofusingavanadateoxidasemethodfordirectbilirubinmeasurementsatanacademicmedicalcenterclinicallaboratory