Cargando…
Development of a Computerized 4-D MRI Phantom for Liver Motion Study
PURPOSE: To develop a 4-dimensional computerized magnetic resonance imaging phantom with image textures extracted from real patient scans for liver motion studies. METHODS: The proposed phantom was developed based on the current version of 4-dimensional extended cardiac-torso computerized phantom an...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5575982/ https://www.ncbi.nlm.nih.gov/pubmed/28789598 http://dx.doi.org/10.1177/1533034617723753 |
_version_ | 1783260130864791552 |
---|---|
author | Wang, Chunhao Yin, Fang-Fang Segars, W. P. Chang, Zheng Ren, Lei |
author_facet | Wang, Chunhao Yin, Fang-Fang Segars, W. P. Chang, Zheng Ren, Lei |
author_sort | Wang, Chunhao |
collection | PubMed |
description | PURPOSE: To develop a 4-dimensional computerized magnetic resonance imaging phantom with image textures extracted from real patient scans for liver motion studies. METHODS: The proposed phantom was developed based on the current version of 4-dimensional extended cardiac-torso computerized phantom and a clinical magnetic resonance scan. Initially, the extended cardiac-torso phantom was voxelized in abdominal–chest region at the end of exhalation phase. Structures/tissues were classified into 4 categories: (1) Seven key textured organs, including liver, gallbladder, spleen, stomach, heart, kidneys, and pancreas, were mapped from a clinical T1-weighted liver magnetic resonance scan using deformable registration. (2) Large textured soft tissue volumes were simulated via an iterative pattern generation method using the same magnetic resonance scan. (3) Lung and intestine structures were generated by assigning uniform intensity with proper noise modeling. (4) Bony structures were generated by assigning the magnetic resonance values. A spherical hypointensity tumor was inserted into the liver. Other respiratory phases of the 4-dimensional phantom were generated using the backward deformation vector fields exported by the extended cardiac-torso program, except that bony structures were generated separately for each phase. A weighted image filtering process was utilized to improve the overall tissue smoothness at each phase. RESULTS: Three 4-dimensional series with different motion amplitudes were generated. The developed motion phantom produced good illustrations of abdominal–chest region with anatomical structures in key organs and texture patterns in large soft tissue volumes. In a standard series, the tumor volume was measured as 13.90 ± 0.11 cm(3) in a respiratory cycle and the tumor’s maximum center-of-mass shift was 2.95 cm/1.84 cm on superior–inferior/anterior–posterior directions. The organ motion during the respiratory cycle was well rendered. The developed motion phantom has the flexibility of motion pattern variation, organ geometry variation, and tumor modeling variation. CONCLUSIONS: A 4-D computerized phantom was developed and could be used to produce image series with synthetic magnetic resonance textures for magnetic resonance imaging research of liver motion. |
format | Online Article Text |
id | pubmed-5575982 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-55759822018-01-17 Development of a Computerized 4-D MRI Phantom for Liver Motion Study Wang, Chunhao Yin, Fang-Fang Segars, W. P. Chang, Zheng Ren, Lei Technol Cancer Res Treat Original Articles PURPOSE: To develop a 4-dimensional computerized magnetic resonance imaging phantom with image textures extracted from real patient scans for liver motion studies. METHODS: The proposed phantom was developed based on the current version of 4-dimensional extended cardiac-torso computerized phantom and a clinical magnetic resonance scan. Initially, the extended cardiac-torso phantom was voxelized in abdominal–chest region at the end of exhalation phase. Structures/tissues were classified into 4 categories: (1) Seven key textured organs, including liver, gallbladder, spleen, stomach, heart, kidneys, and pancreas, were mapped from a clinical T1-weighted liver magnetic resonance scan using deformable registration. (2) Large textured soft tissue volumes were simulated via an iterative pattern generation method using the same magnetic resonance scan. (3) Lung and intestine structures were generated by assigning uniform intensity with proper noise modeling. (4) Bony structures were generated by assigning the magnetic resonance values. A spherical hypointensity tumor was inserted into the liver. Other respiratory phases of the 4-dimensional phantom were generated using the backward deformation vector fields exported by the extended cardiac-torso program, except that bony structures were generated separately for each phase. A weighted image filtering process was utilized to improve the overall tissue smoothness at each phase. RESULTS: Three 4-dimensional series with different motion amplitudes were generated. The developed motion phantom produced good illustrations of abdominal–chest region with anatomical structures in key organs and texture patterns in large soft tissue volumes. In a standard series, the tumor volume was measured as 13.90 ± 0.11 cm(3) in a respiratory cycle and the tumor’s maximum center-of-mass shift was 2.95 cm/1.84 cm on superior–inferior/anterior–posterior directions. The organ motion during the respiratory cycle was well rendered. The developed motion phantom has the flexibility of motion pattern variation, organ geometry variation, and tumor modeling variation. CONCLUSIONS: A 4-D computerized phantom was developed and could be used to produce image series with synthetic magnetic resonance textures for magnetic resonance imaging research of liver motion. SAGE Publications 2017-08-09 2017-12 /pmc/articles/PMC5575982/ /pubmed/28789598 http://dx.doi.org/10.1177/1533034617723753 Text en © The Author(s) 2017 http://creativecommons.org/licenses/by/4.0/ This article is distributed under the terms of the Creative Commons Attribution 4.0 License (http://www.creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Articles Wang, Chunhao Yin, Fang-Fang Segars, W. P. Chang, Zheng Ren, Lei Development of a Computerized 4-D MRI Phantom for Liver Motion Study |
title | Development of a Computerized 4-D MRI Phantom for Liver Motion Study |
title_full | Development of a Computerized 4-D MRI Phantom for Liver Motion Study |
title_fullStr | Development of a Computerized 4-D MRI Phantom for Liver Motion Study |
title_full_unstemmed | Development of a Computerized 4-D MRI Phantom for Liver Motion Study |
title_short | Development of a Computerized 4-D MRI Phantom for Liver Motion Study |
title_sort | development of a computerized 4-d mri phantom for liver motion study |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5575982/ https://www.ncbi.nlm.nih.gov/pubmed/28789598 http://dx.doi.org/10.1177/1533034617723753 |
work_keys_str_mv | AT wangchunhao developmentofacomputerized4dmriphantomforlivermotionstudy AT yinfangfang developmentofacomputerized4dmriphantomforlivermotionstudy AT segarswp developmentofacomputerized4dmriphantomforlivermotionstudy AT changzheng developmentofacomputerized4dmriphantomforlivermotionstudy AT renlei developmentofacomputerized4dmriphantomforlivermotionstudy |