Cargando…

Development of a Computerized 4-D MRI Phantom for Liver Motion Study

PURPOSE: To develop a 4-dimensional computerized magnetic resonance imaging phantom with image textures extracted from real patient scans for liver motion studies. METHODS: The proposed phantom was developed based on the current version of 4-dimensional extended cardiac-torso computerized phantom an...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Chunhao, Yin, Fang-Fang, Segars, W. P., Chang, Zheng, Ren, Lei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5575982/
https://www.ncbi.nlm.nih.gov/pubmed/28789598
http://dx.doi.org/10.1177/1533034617723753
_version_ 1783260130864791552
author Wang, Chunhao
Yin, Fang-Fang
Segars, W. P.
Chang, Zheng
Ren, Lei
author_facet Wang, Chunhao
Yin, Fang-Fang
Segars, W. P.
Chang, Zheng
Ren, Lei
author_sort Wang, Chunhao
collection PubMed
description PURPOSE: To develop a 4-dimensional computerized magnetic resonance imaging phantom with image textures extracted from real patient scans for liver motion studies. METHODS: The proposed phantom was developed based on the current version of 4-dimensional extended cardiac-torso computerized phantom and a clinical magnetic resonance scan. Initially, the extended cardiac-torso phantom was voxelized in abdominal–chest region at the end of exhalation phase. Structures/tissues were classified into 4 categories: (1) Seven key textured organs, including liver, gallbladder, spleen, stomach, heart, kidneys, and pancreas, were mapped from a clinical T1-weighted liver magnetic resonance scan using deformable registration. (2) Large textured soft tissue volumes were simulated via an iterative pattern generation method using the same magnetic resonance scan. (3) Lung and intestine structures were generated by assigning uniform intensity with proper noise modeling. (4) Bony structures were generated by assigning the magnetic resonance values. A spherical hypointensity tumor was inserted into the liver. Other respiratory phases of the 4-dimensional phantom were generated using the backward deformation vector fields exported by the extended cardiac-torso program, except that bony structures were generated separately for each phase. A weighted image filtering process was utilized to improve the overall tissue smoothness at each phase. RESULTS: Three 4-dimensional series with different motion amplitudes were generated. The developed motion phantom produced good illustrations of abdominal–chest region with anatomical structures in key organs and texture patterns in large soft tissue volumes. In a standard series, the tumor volume was measured as 13.90 ± 0.11 cm(3) in a respiratory cycle and the tumor’s maximum center-of-mass shift was 2.95 cm/1.84 cm on superior–inferior/anterior–posterior directions. The organ motion during the respiratory cycle was well rendered. The developed motion phantom has the flexibility of motion pattern variation, organ geometry variation, and tumor modeling variation. CONCLUSIONS: A 4-D computerized phantom was developed and could be used to produce image series with synthetic magnetic resonance textures for magnetic resonance imaging research of liver motion.
format Online
Article
Text
id pubmed-5575982
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-55759822018-01-17 Development of a Computerized 4-D MRI Phantom for Liver Motion Study Wang, Chunhao Yin, Fang-Fang Segars, W. P. Chang, Zheng Ren, Lei Technol Cancer Res Treat Original Articles PURPOSE: To develop a 4-dimensional computerized magnetic resonance imaging phantom with image textures extracted from real patient scans for liver motion studies. METHODS: The proposed phantom was developed based on the current version of 4-dimensional extended cardiac-torso computerized phantom and a clinical magnetic resonance scan. Initially, the extended cardiac-torso phantom was voxelized in abdominal–chest region at the end of exhalation phase. Structures/tissues were classified into 4 categories: (1) Seven key textured organs, including liver, gallbladder, spleen, stomach, heart, kidneys, and pancreas, were mapped from a clinical T1-weighted liver magnetic resonance scan using deformable registration. (2) Large textured soft tissue volumes were simulated via an iterative pattern generation method using the same magnetic resonance scan. (3) Lung and intestine structures were generated by assigning uniform intensity with proper noise modeling. (4) Bony structures were generated by assigning the magnetic resonance values. A spherical hypointensity tumor was inserted into the liver. Other respiratory phases of the 4-dimensional phantom were generated using the backward deformation vector fields exported by the extended cardiac-torso program, except that bony structures were generated separately for each phase. A weighted image filtering process was utilized to improve the overall tissue smoothness at each phase. RESULTS: Three 4-dimensional series with different motion amplitudes were generated. The developed motion phantom produced good illustrations of abdominal–chest region with anatomical structures in key organs and texture patterns in large soft tissue volumes. In a standard series, the tumor volume was measured as 13.90 ± 0.11 cm(3) in a respiratory cycle and the tumor’s maximum center-of-mass shift was 2.95 cm/1.84 cm on superior–inferior/anterior–posterior directions. The organ motion during the respiratory cycle was well rendered. The developed motion phantom has the flexibility of motion pattern variation, organ geometry variation, and tumor modeling variation. CONCLUSIONS: A 4-D computerized phantom was developed and could be used to produce image series with synthetic magnetic resonance textures for magnetic resonance imaging research of liver motion. SAGE Publications 2017-08-09 2017-12 /pmc/articles/PMC5575982/ /pubmed/28789598 http://dx.doi.org/10.1177/1533034617723753 Text en © The Author(s) 2017 http://creativecommons.org/licenses/by/4.0/ This article is distributed under the terms of the Creative Commons Attribution 4.0 License (http://www.creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Articles
Wang, Chunhao
Yin, Fang-Fang
Segars, W. P.
Chang, Zheng
Ren, Lei
Development of a Computerized 4-D MRI Phantom for Liver Motion Study
title Development of a Computerized 4-D MRI Phantom for Liver Motion Study
title_full Development of a Computerized 4-D MRI Phantom for Liver Motion Study
title_fullStr Development of a Computerized 4-D MRI Phantom for Liver Motion Study
title_full_unstemmed Development of a Computerized 4-D MRI Phantom for Liver Motion Study
title_short Development of a Computerized 4-D MRI Phantom for Liver Motion Study
title_sort development of a computerized 4-d mri phantom for liver motion study
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5575982/
https://www.ncbi.nlm.nih.gov/pubmed/28789598
http://dx.doi.org/10.1177/1533034617723753
work_keys_str_mv AT wangchunhao developmentofacomputerized4dmriphantomforlivermotionstudy
AT yinfangfang developmentofacomputerized4dmriphantomforlivermotionstudy
AT segarswp developmentofacomputerized4dmriphantomforlivermotionstudy
AT changzheng developmentofacomputerized4dmriphantomforlivermotionstudy
AT renlei developmentofacomputerized4dmriphantomforlivermotionstudy