Cargando…

Atypical Presentation of a Type 2 Endoleak following Emergency Open Repair of a Ruptured Abdominal Aortic Aneurysm

BACKGROUND: An endoleak is a common complication following EVAR. Specifically, a Type 2 endoleak occurs because of retrograde flow from lumbar vessels outside the endograft within the aneurysm sac. Even though it is common following EVAR, it has not been identified as a complication following open r...

Descripción completa

Detalles Bibliográficos
Autores principales: Sharma, K., Halandras, P., Milner, R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5576093/
https://www.ncbi.nlm.nih.gov/pubmed/28856320
http://dx.doi.org/10.1016/j.ejvssr.2016.09.002
Descripción
Sumario:BACKGROUND: An endoleak is a common complication following EVAR. Specifically, a Type 2 endoleak occurs because of retrograde flow from lumbar vessels outside the endograft within the aneurysm sac. Even though it is common following EVAR, it has not been identified as a complication following open ruptured abdominal aortic aneurysm (AAA) repair. REPORT: A 73-year-old male underwent open repair of a ruptured AAA. Five months later, computed tomography revealed filling from a lumbar vessel mimicking a Type 2 “endoleak.” The initial ultrasound showed a single pair of lumbar vessels with aneurysm sac expansion 8 weeks later. The “endoleak” and expanding sac were treated, and the 2-year surveillance demonstrated sac shrinkage. DISCUSSION: Because endoleak is a complication after EVAR, this case provides a unique presentation of Type 2 “endoleak” physiology following open repair of a ruptured AAA. It is believed that it is necessary to expand the list of possible complications after open ruptured AAA repair to include “endoleaks.”