Anterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture
We describe the case of a patient with distal radius fracture who became unable to flex the distal interphalangeal joint of the index finger after internal fixation using a volar locking plate. There was palpable crepitus with active thumb motion, and wrist radiographs showed prominence of the volar...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nagoya University
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5577028/ https://www.ncbi.nlm.nih.gov/pubmed/28878447 http://dx.doi.org/10.18999/nagjms.79.3.421 |
_version_ | 1783260266891313152 |
---|---|
author | Shinohara, Takaaki Takahashi, Sayako Hirata, Hitoshi |
author_facet | Shinohara, Takaaki Takahashi, Sayako Hirata, Hitoshi |
author_sort | Shinohara, Takaaki |
collection | PubMed |
description | We describe the case of a patient with distal radius fracture who became unable to flex the distal interphalangeal joint of the index finger after internal fixation using a volar locking plate. There was palpable crepitus with active thumb motion, and wrist radiographs showed prominence of the volar plate at the watershed line. Therefore, our initial diagnosis was plate-induced closed rupture of the flexor digitorum profundus tendon of the index finger. However, upon surgical removal of the plate, no tendon rupture was found. Magnetic resonance imaging after plate removal showed diffuse increased signal intensity in the index flexor digitorum profundus on T2-weighted fat-suppressed images, which indicated muscle denervation. Based on the above findings, we changed the diagnosis to anterior interosseous nerve palsy with isolated paralysis of the flexor digitorum profundus of the index finger. Finger flexion disability following volar plate fixation of distal radius fracture should always be investigated carefully.. |
format | Online Article Text |
id | pubmed-5577028 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Nagoya University |
record_format | MEDLINE/PubMed |
spelling | pubmed-55770282017-09-06 Anterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture Shinohara, Takaaki Takahashi, Sayako Hirata, Hitoshi Nagoya J Med Sci Case Report We describe the case of a patient with distal radius fracture who became unable to flex the distal interphalangeal joint of the index finger after internal fixation using a volar locking plate. There was palpable crepitus with active thumb motion, and wrist radiographs showed prominence of the volar plate at the watershed line. Therefore, our initial diagnosis was plate-induced closed rupture of the flexor digitorum profundus tendon of the index finger. However, upon surgical removal of the plate, no tendon rupture was found. Magnetic resonance imaging after plate removal showed diffuse increased signal intensity in the index flexor digitorum profundus on T2-weighted fat-suppressed images, which indicated muscle denervation. Based on the above findings, we changed the diagnosis to anterior interosseous nerve palsy with isolated paralysis of the flexor digitorum profundus of the index finger. Finger flexion disability following volar plate fixation of distal radius fracture should always be investigated carefully.. Nagoya University 2017-08 /pmc/articles/PMC5577028/ /pubmed/28878447 http://dx.doi.org/10.18999/nagjms.79.3.421 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an Open Access article distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Shinohara, Takaaki Takahashi, Sayako Hirata, Hitoshi Anterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture |
title | Anterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture |
title_full | Anterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture |
title_fullStr | Anterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture |
title_full_unstemmed | Anterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture |
title_short | Anterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture |
title_sort | anterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5577028/ https://www.ncbi.nlm.nih.gov/pubmed/28878447 http://dx.doi.org/10.18999/nagjms.79.3.421 |
work_keys_str_mv | AT shinoharatakaaki anteriorinterosseousnervepalsymimickingruptureoftheindexflexordigitorumprofundusaftervolarlockingplatefixationofadistalradiusfracture AT takahashisayako anteriorinterosseousnervepalsymimickingruptureoftheindexflexordigitorumprofundusaftervolarlockingplatefixationofadistalradiusfracture AT hiratahitoshi anteriorinterosseousnervepalsymimickingruptureoftheindexflexordigitorumprofundusaftervolarlockingplatefixationofadistalradiusfracture |