Cargando…

Anterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture

We describe the case of a patient with distal radius fracture who became unable to flex the distal interphalangeal joint of the index finger after internal fixation using a volar locking plate. There was palpable crepitus with active thumb motion, and wrist radiographs showed prominence of the volar...

Descripción completa

Detalles Bibliográficos
Autores principales: Shinohara, Takaaki, Takahashi, Sayako, Hirata, Hitoshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nagoya University 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5577028/
https://www.ncbi.nlm.nih.gov/pubmed/28878447
http://dx.doi.org/10.18999/nagjms.79.3.421
_version_ 1783260266891313152
author Shinohara, Takaaki
Takahashi, Sayako
Hirata, Hitoshi
author_facet Shinohara, Takaaki
Takahashi, Sayako
Hirata, Hitoshi
author_sort Shinohara, Takaaki
collection PubMed
description We describe the case of a patient with distal radius fracture who became unable to flex the distal interphalangeal joint of the index finger after internal fixation using a volar locking plate. There was palpable crepitus with active thumb motion, and wrist radiographs showed prominence of the volar plate at the watershed line. Therefore, our initial diagnosis was plate-induced closed rupture of the flexor digitorum profundus tendon of the index finger. However, upon surgical removal of the plate, no tendon rupture was found. Magnetic resonance imaging after plate removal showed diffuse increased signal intensity in the index flexor digitorum profundus on T2-weighted fat-suppressed images, which indicated muscle denervation. Based on the above findings, we changed the diagnosis to anterior interosseous nerve palsy with isolated paralysis of the flexor digitorum profundus of the index finger. Finger flexion disability following volar plate fixation of distal radius fracture should always be investigated carefully..
format Online
Article
Text
id pubmed-5577028
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Nagoya University
record_format MEDLINE/PubMed
spelling pubmed-55770282017-09-06 Anterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture Shinohara, Takaaki Takahashi, Sayako Hirata, Hitoshi Nagoya J Med Sci Case Report We describe the case of a patient with distal radius fracture who became unable to flex the distal interphalangeal joint of the index finger after internal fixation using a volar locking plate. There was palpable crepitus with active thumb motion, and wrist radiographs showed prominence of the volar plate at the watershed line. Therefore, our initial diagnosis was plate-induced closed rupture of the flexor digitorum profundus tendon of the index finger. However, upon surgical removal of the plate, no tendon rupture was found. Magnetic resonance imaging after plate removal showed diffuse increased signal intensity in the index flexor digitorum profundus on T2-weighted fat-suppressed images, which indicated muscle denervation. Based on the above findings, we changed the diagnosis to anterior interosseous nerve palsy with isolated paralysis of the flexor digitorum profundus of the index finger. Finger flexion disability following volar plate fixation of distal radius fracture should always be investigated carefully.. Nagoya University 2017-08 /pmc/articles/PMC5577028/ /pubmed/28878447 http://dx.doi.org/10.18999/nagjms.79.3.421 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an Open Access article distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Shinohara, Takaaki
Takahashi, Sayako
Hirata, Hitoshi
Anterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture
title Anterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture
title_full Anterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture
title_fullStr Anterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture
title_full_unstemmed Anterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture
title_short Anterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture
title_sort anterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5577028/
https://www.ncbi.nlm.nih.gov/pubmed/28878447
http://dx.doi.org/10.18999/nagjms.79.3.421
work_keys_str_mv AT shinoharatakaaki anteriorinterosseousnervepalsymimickingruptureoftheindexflexordigitorumprofundusaftervolarlockingplatefixationofadistalradiusfracture
AT takahashisayako anteriorinterosseousnervepalsymimickingruptureoftheindexflexordigitorumprofundusaftervolarlockingplatefixationofadistalradiusfracture
AT hiratahitoshi anteriorinterosseousnervepalsymimickingruptureoftheindexflexordigitorumprofundusaftervolarlockingplatefixationofadistalradiusfracture