Optimization of urinary dipstick pH: Are multiple dipstick pH readings reliably comparable to commercial 24-hour urinary pH?

PURPOSE: Accurate measurement of pH is necessary to guide medical management of nephrolithiasis. Urinary dipsticks offer a convenient method to measure pH, but prior studies have only assessed the accuracy of a single, spot dipstick. Given the known diurnal variation in pH, a single dipstick pH is u...

Descripción completa

Detalles Bibliográficos
Autores principales: Abbott, Joel E., Miller, Daniel L., Shi, William, Wenzler, David, Elkhoury, Fuad F., Patel, Nishant D., Sur, Roger L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Urological Association 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5577336/
https://www.ncbi.nlm.nih.gov/pubmed/28868511
http://dx.doi.org/10.4111/icu.2017.58.5.378
_version_ 1783260340611448832
author Abbott, Joel E.
Miller, Daniel L.
Shi, William
Wenzler, David
Elkhoury, Fuad F.
Patel, Nishant D.
Sur, Roger L.
author_facet Abbott, Joel E.
Miller, Daniel L.
Shi, William
Wenzler, David
Elkhoury, Fuad F.
Patel, Nishant D.
Sur, Roger L.
author_sort Abbott, Joel E.
collection PubMed
description PURPOSE: Accurate measurement of pH is necessary to guide medical management of nephrolithiasis. Urinary dipsticks offer a convenient method to measure pH, but prior studies have only assessed the accuracy of a single, spot dipstick. Given the known diurnal variation in pH, a single dipstick pH is unlikely to reflect the average daily urinary pH. Our goal was to determine whether multiple dipstick pH readings would be reliably comparable to pH from a 24-hour urine analysis. MATERIALS AND METHODS: Kidney stone patients undergoing a 24-hour urine collection were enrolled and took images of dipsticks from their first 3 voids concurrently with the 24-hour collection. Images were sent to and read by a study investigator. The individual and mean pH from the dipsticks were compared to the 24-hour urine pH and considered to be accurate if the dipstick readings were within 0.5 of the 24-hour urine pH. The Bland-Altman test of agreement was used to further compare dipstick pH relative to 24-hour urine pH. RESULTS: Fifty-nine percent of patients had mean urinary pH values within 0.5 pH units of their 24-hour urine pH. Bland-Altman analysis showed a mean difference between dipstick pH and 24-hour urine pH of -0.22, with an upper limit of agreement of 1.02 (95% confidence interval [CI], 0.45–1.59) and a lower limit of agreement of -1.47 (95% CI, -2.04 to -0.90). CONCLUSIONS: We concluded that urinary dipstick based pH measurement lacks the precision required to guide medical management of nephrolithiasis and physicians should use 24-hour urine analysis to base their metabolic therapy.
format Online
Article
Text
id pubmed-5577336
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher The Korean Urological Association
record_format MEDLINE/PubMed
spelling pubmed-55773362017-09-02 Optimization of urinary dipstick pH: Are multiple dipstick pH readings reliably comparable to commercial 24-hour urinary pH? Abbott, Joel E. Miller, Daniel L. Shi, William Wenzler, David Elkhoury, Fuad F. Patel, Nishant D. Sur, Roger L. Investig Clin Urol Original Article PURPOSE: Accurate measurement of pH is necessary to guide medical management of nephrolithiasis. Urinary dipsticks offer a convenient method to measure pH, but prior studies have only assessed the accuracy of a single, spot dipstick. Given the known diurnal variation in pH, a single dipstick pH is unlikely to reflect the average daily urinary pH. Our goal was to determine whether multiple dipstick pH readings would be reliably comparable to pH from a 24-hour urine analysis. MATERIALS AND METHODS: Kidney stone patients undergoing a 24-hour urine collection were enrolled and took images of dipsticks from their first 3 voids concurrently with the 24-hour collection. Images were sent to and read by a study investigator. The individual and mean pH from the dipsticks were compared to the 24-hour urine pH and considered to be accurate if the dipstick readings were within 0.5 of the 24-hour urine pH. The Bland-Altman test of agreement was used to further compare dipstick pH relative to 24-hour urine pH. RESULTS: Fifty-nine percent of patients had mean urinary pH values within 0.5 pH units of their 24-hour urine pH. Bland-Altman analysis showed a mean difference between dipstick pH and 24-hour urine pH of -0.22, with an upper limit of agreement of 1.02 (95% confidence interval [CI], 0.45–1.59) and a lower limit of agreement of -1.47 (95% CI, -2.04 to -0.90). CONCLUSIONS: We concluded that urinary dipstick based pH measurement lacks the precision required to guide medical management of nephrolithiasis and physicians should use 24-hour urine analysis to base their metabolic therapy. The Korean Urological Association 2017-09 2017-07-24 /pmc/articles/PMC5577336/ /pubmed/28868511 http://dx.doi.org/10.4111/icu.2017.58.5.378 Text en © The Korean Urological Association, 2017 http://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Abbott, Joel E.
Miller, Daniel L.
Shi, William
Wenzler, David
Elkhoury, Fuad F.
Patel, Nishant D.
Sur, Roger L.
Optimization of urinary dipstick pH: Are multiple dipstick pH readings reliably comparable to commercial 24-hour urinary pH?
title Optimization of urinary dipstick pH: Are multiple dipstick pH readings reliably comparable to commercial 24-hour urinary pH?
title_full Optimization of urinary dipstick pH: Are multiple dipstick pH readings reliably comparable to commercial 24-hour urinary pH?
title_fullStr Optimization of urinary dipstick pH: Are multiple dipstick pH readings reliably comparable to commercial 24-hour urinary pH?
title_full_unstemmed Optimization of urinary dipstick pH: Are multiple dipstick pH readings reliably comparable to commercial 24-hour urinary pH?
title_short Optimization of urinary dipstick pH: Are multiple dipstick pH readings reliably comparable to commercial 24-hour urinary pH?
title_sort optimization of urinary dipstick ph: are multiple dipstick ph readings reliably comparable to commercial 24-hour urinary ph?
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5577336/
https://www.ncbi.nlm.nih.gov/pubmed/28868511
http://dx.doi.org/10.4111/icu.2017.58.5.378
work_keys_str_mv AT abbottjoele optimizationofurinarydipstickpharemultipledipstickphreadingsreliablycomparabletocommercial24hoururinaryph
AT millerdaniell optimizationofurinarydipstickpharemultipledipstickphreadingsreliablycomparabletocommercial24hoururinaryph
AT shiwilliam optimizationofurinarydipstickpharemultipledipstickphreadingsreliablycomparabletocommercial24hoururinaryph
AT wenzlerdavid optimizationofurinarydipstickpharemultipledipstickphreadingsreliablycomparabletocommercial24hoururinaryph
AT elkhouryfuadf optimizationofurinarydipstickpharemultipledipstickphreadingsreliablycomparabletocommercial24hoururinaryph
AT patelnishantd optimizationofurinarydipstickpharemultipledipstickphreadingsreliablycomparabletocommercial24hoururinaryph
AT surrogerl optimizationofurinarydipstickpharemultipledipstickphreadingsreliablycomparabletocommercial24hoururinaryph